ABB Installation Products K151SR-D2270 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not…
UPC: 783786039562
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15/25kV Deadbreak Elbow Straight Receptacle
- Accommodates cable insulation diameters from 0.890" to 1.220"
- Features a copper compression lug for secure conductor connection
- Supports 4/0 AWG compressed stranded or 250 kcmil solid conductors
- Bails required, sold separately
Specifications
Amperage Rating | 200 A |
Application | Designed to connect a cable to another cable or apparatus |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection Type | Deadbreak Elbow, Straight Receptacle |
Current Rating | 200 A |
Environmental Conditions | Fully Shielded, Fully Submersible |
Insulation | True |
Length | 9.54 in |
Length | 242.316 mm |
Material | Copper Compression Lug |
Material | Housing - EPDM-Rubber |
Series | K151SR |
Size | Cable Insulation Diameter 0.890 inch to 1.220 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for ground wire connection. Wide cable range with minimum number of sizes. No Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Straight Receptacle |
Voltage Rating | 15 to 25 kV |
Voltage Rating | 15/25 kV |
Width | 2.74 in |
Width | 69.596 mm |
Package Dimensions (L x W x H) | 8.5 IN x 19 IN x 12.5 IN |
Package Dimensions (L x W x H) | 21.59 cm x 48.26 cm x 31.75 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
K151SR-C0210
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #3 or Solid #2 or mmSquared 26.67.
K151SP-B0200
15/25kV 200 Amp, Deadbreak Straight Plug, Bails are required, but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #4/Solid #3/mmSquared 21.14.
168ELR-6689-5250
15kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Bi-Metal Contact. Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid
273RLRJ-5270
200 Amp, 25kV, Loadbreak Replacement Elbow Connector without Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
168RLR-F-5210
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
168RLR-G-5260
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
168RLR-G5220
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.Frequently Asked Questions
What type of cables is the K151SR designed for?
The K151SR is designed to terminate UD cable having concentric neutral and extruded insulation shielding. It can terminate other types with a proper adapter.
What voltage systems is the K151SR suitable for?
The K151SR is suitable for use on both 15kV and 25kV systems.
What is the K151SR product used for?
The Elastimold K151SR Straight Receptacle connects a cable to another cable or apparatus. It requires an appropriate Elastimold mating product.
What is the continuous current rating for the K151SR?
The K151SR has a continuous current rating of 200 Amp for both 15kV and 25kV voltage classes.
What is the maximum operating voltage for 25kV class?
For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV.
What cable conductor sizes can the K151SR accommodate?
The K151SR can accommodate conductor sizes from No. 4 solid through 4/0 stranded.
What cable insulation diameters are compatible with K151SR?
The K151SR accommodates cable insulation diameters from .575 inches through 1.220 inches.
What items are included in a K151SR kit?
Each kit contains a straight receptacle housing, a receptacle pin connector, a tube of lubricant, installation instructions, and a crimp chart.
When can the K151SR's disconnectible feature be used?
The disconnectible feature of the K151SR can be used only when the circuit is de-energized.
What standards does the K151SR meet?
The K151SR meets ANSI/IEEE Standard 386, Latest Revision.
How to Install the Elastimold 151SR/K151SR Straight Receptacle
This guide provides step-by-step instructions for preparing the cable, installing the conductor contact, and connecting the Elastimold 151SR/K151SR Straight Receptacle for high-voltage cable systems.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Crimping tool, Wire brush, Rag
Supplies needed:
Elastimold 151SR/K151SR Straight Receptacle kit, Approved solvent, #14 AWG (or equivalent) copper wire, Elastimold bail, Silicone grease, Elastimold insulating plug (K150DP)
- Prepare for Installation and Ensure Safety
Before beginning, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high-voltage safety practices. Inspect all parts for damage, proper rating, and compatibility with mating products. Gather all required tools and maintain a clean work area throughout the procedure.
- Prepare the Cable Jacket and Shield
For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. If using an ECS or MA grounding device, follow its specific instructions for outer jacket cut-back.
- Prepare Cable Insulation and Conductor
Remove 7/8 inch to 1 inch of cable insulation and conductive shield. For #1 stranded/compressed and #1/0 compressed/solid aluminum cable, remove 1 3/4 inches to 1 7/8 inches. Cut the insulation squarely, avoiding any penciling at this stage. Wire brush any bare aluminum conductors immediately and insert them into the crimp barrel, which contains an inhibitor.
- Crimp the Conductor Contact
Crimp the socket terminal onto the bared conductor, ensuring the conductor remains fully seated within the connector. Refer to the crimp chart provided with the contact for proper crimping instructions. Start crimps at the imprinted crimp line and rotate each successive crimp or indent 90 degrees. If using aluminum cable, carefully wipe any excess inhibitor from the contact and cable insulation.
- Prepare and Clean Semi-Conductive Shield and Insulation
Remove the semi-conductive shield to a point 7 9/16 inches to 7 5/8 inches back from the end of the pin with a straight, smooth, 'squared' cut. DO NOT CUT OR NICK THE INSULATION. Pencil the insulation 1/8 inch. Thoroughly clean the outer jacket and insulation with a rag wet with an approved solvent, wiping from the cable end toward the outer jacket to remove all traces of semi-conducting residue. If using an ECS or MA grounding device, install it now following its specific instructions.
- Lubricate Receptacle and Cable
Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable as shown in the instructions and to the inside of the receptacle housing. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product or its mating component.
- Install Cable into Receptacle Housing
Carefully push the prepared cable into the receptacle housing until the base of the pin chamfer is flush with the inside face of the receptacle. If the receptacle will not be immediately connected to a mating plug, replace the protective cover. Note that the shipping cover only offers protection from dirt and is not an insulating device; obtain an Elastimold insulating plug (K150DP) if an insulating device is required.
- Connect to a Mating Plug (If Applicable)
If connecting to a mating plug, first lubricate the nose of the plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), taking care not to cut the rod. Insert the plug assembly into the receptacle as far as possible, then pull out the nylon rod. Finally, secure the electrical connection using an Elastimold bail.
- Ground the Cable Connection
If an ELASTIMOLD grounding device is not being used, connect a length of #14 AWG (or equivalent) copper wire (customer supplied) through the grounding tab and twist it tightly. Connect this grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal all grounding wires and connections to prevent corrosion.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.