Authorized ABB Distributor (Installation Products)
ABB - Installation Products 168RLR-G-5260 - 15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

ABB Installation Products 168RLR-G-5260 15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation…

UPC: 783786093168


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168RLR-G-5260 is a fully rated 15kV, 200 Amp Class loadbreak elbow connector designed for medium-voltage applications. This Elastimold® replacement elbow features an extended length housing and compression lug, providing an additional 10-1/2 inches (266.7 mm) to accommodate cables that are too short for standard elbows. It is engineered for connecting to and operating 15kV Class, 95kV BIL apparatus. The connector meets ANSI/IEEE Standard 386, Latest Revision, with a maximum operating voltage of 8.3kV phase-to-ground and 14.4kV phase-to-phase. It boasts a 95kV BIL impulse withstand (1.2 x 50 microsecond wave), a 34kV AC one-minute withstand, and a 53kV DC 15-minute withstand. Corona extinction is rated at 11kV AC @ 3pC sensitivity. The continuous and loadbreak rating is 200 Amps, with a 10kA Sym momentary and fault close rating for 10 cycles. Key features include a fully shielded, fully submersible molded rubber housing, 100% peroxide-cured insulation, insert, and jacket. It offers provisions for hot stick operation and ground wire connection, supporting a wide cable range with a minimal number of cable sizes. The non-corrosive capacitive test point allows for safe voltage verification. The 168RLR-G-5260 is compatible with cable insulation diameters ranging from 0.760 inches to 0.950 inches (19.30 mm to 24.13 mm), identified by the 'G' code. It accommodates compressed stranded conductors in sizes 3/0 AWG and 4/0 AWG, solid conductors, and 85.01 mm² cross-sections. Each kit includes the elbow connector housing, a bi-metal compression lug, probe wrench, probe, lubricant, installation instructions, hose clamp, and a crimp chart. This robust connector is ideal for underground distribution systems, switchgear connections, and transformer terminations requiring reliable loadbreak functionality and accessible test points.
  • 15kV, 200A Class Loadbreak Elbow Connector with Extended Length
  • Accommodates cables too short for standard elbows (+10-1/2" length)
  • Fully shielded, fully submersible molded rubber housing
  • Non-corrosive capacitive test point for safe voltage verification
  • Meets ANSI/IEEE Standard 386, 95kV BIL, 200A continuous/loadbreak

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal, Poly
Series
168RLR
Size
Cable Insulation Diameter 0.760 inch to 0.950 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.

K656CY-H0260-S

15-25kV 600 Series Deadbreak Separable Wye Joint Package (3-Way) with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

168RLR-G5220

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Bi-Metal Compression Lug.

167ELR-6689-5240

15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.665 inch to 0.895 inch. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

274RLR-J5250

25kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Bi-metal compression lug.

167ELR-88110-5270

15kV 200 Amp, Loadbreak Repair Elbow Connector, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Bi-metal compression lug.
25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Bi-Metal Compression lug.

274ELR-88110-5260

25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Bi-Metal Compression lug.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.

376LR-J5240-S

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS Jacket Seal Included.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274RLR-K-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

Frequently Asked Questions

What is the maximum voltage rating of this connector?

The connector is rated for 15kV maximum operating voltage.

What cable insulation diameters does this support?

The connector accommodates cable insulation diameters from 0.760 inch to 0.950 inch.

What conductor sizes are compatible with this elbow?

The connector supports compressed stranded conductors in sizes 3/0 AWG and 4/0 AWG, solid conductors, and 85.01 mm² cross-sections.

Does this connector include a test point?

Yes, the connector features an integrated test point for safe voltage verification.

Is this a loadbreak or deadbreak connector?

This is a loadbreak replacement elbow connector, designed for safe operation under load.

What is the current rating of this connector?

The connector has a continuous current rating of 200 Amps.

Is the lug bi-metal or copper?

The connector uses a bi-metal compression lug for improved conductivity and corrosion resistance.

How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cables.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Hotstick, Wire brush, Wrench, Suitable sensing device (for capacitive test points), Wire strippers

Supplies needed:

Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, Do Not Substitute), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate connector (for neutral to ground), Silicone grease

  1. Prepare for Installation and De-energize Apparatus

    Before starting, check the package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Thread the probe into the compression lug to check for resistance. Read all instructions. Ensure all required tools are at hand and maintain cleanliness. DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators which can be installed and operated energized. Do not touch or move energized products. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

  2. Remove Livefront Terminator

    Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  3. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches, proceed. If greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end, cutting squarely. DO NOT NICK THE CONDUCTOR.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductor immediately. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess grease, ensuring none enters the gap between the lug and insulation. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.

  6. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. Add the supplied hose clamp as shown and tighten it snugly, but do not overtighten.

  7. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface.

  8. Perform Voltage Test (168RLR Only)

    For 168RLR models, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points. Contamination or incorrect equipment can provide a false 'no voltage' indication. Treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.