ABB - Installation Products 262LRJS-C5270 - 200 Amp, 25kV, Loadbreak Jacket Seal Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
ABB - Installation Products

262LRJS-C5270

UPC: 075114284103


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 262LRJS-C5270 is a 200 Amp, 25kV loadbreak jacket seal elbow with an integrated test point, engineered for medium-voltage cable terminations in underground and overhead distribution systems. This bi-metal compression lug elbow accommodates cable insulation diameters from 0.805 inch to 1.060 inch and supports conductor sizes ranging from AWG 4/0 compressed stranded to 250 mm² solid (126.67 mm² equivalent). The compression lug connection ensures a secure, low-resistance joint, reducing heat buildup and extending service life in high-load applications. Designed for compatibility with 25kV class systems, the 262LRJS-C5270 provides a reliable loadbreak interface, allowing for safe energized circuit connections and disconnections without de-energizing the entire system. The jacket seal design maintains environmental protection against moisture and contaminants, while the test point enables quick voltage verification without disturbing the primary connection. This elbow is ideal for utility, industrial, and commercial power distribution networks where operational safety and system reliability are critical. Key applications include pad-mounted transformers, switchgear, and underground residential or commercial feeders. The bi-metal construction (aluminum-to-copper) minimizes galvanic corrosion risks, ensuring long-term performance in harsh environments. With a current rating of 200 Amps and a voltage rating of 25kV, this elbow meets the demands of modern medium-voltage distribution networks. Order SKU 262LRJS-C5270 for a durable, field-proven solution backed by ABB’s installation products division.
  • 200 Amp current rating for medium-voltage distribution
  • 25kV voltage rating with loadbreak capability
  • Bi-metal compression lug for AWG 4/0 to 250 mm² conductors
  • Integrated test point for safe voltage verification
  • Jacket seal design for environmental protection

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
All Weather Conditions
Insulation
True
Length
11.47 in
Length
291.338 mm
Material
Housing - EPDM-Rubber
Special Features
25kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in cable jacket seal. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point and Jacket Seal
Voltage Rating
28 kV
Width
8.2 in
Width
208.28 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

261LRJS-D5270

25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
25kV, 200 Amp, Elbow. LoadBreak. Bi-Metal Compression Lug. Cable Insulation Diameter 0.805 inch to 1.060 inch. Conductor Size Compressed Stranded #1 or Compacted Solid 1/0. With Jacket Seal. With Test Point.

262LRJS-C5230A

25kV, 200 Amp, Elbow. LoadBreak. Bi-Metal Compression Lug. Cable Insulation Diameter 0.805 inch to 1.060 inch. Conductor Size Compressed Stranded #1 or Compacted Solid 1/0. With Jacket Seal. With Test Point.
25kV, 200 Amp, Elbow. LoadBreak. Bi-Metal Compression Lug. Cable Insulation Diameter 0.805 inch to 1.060 inch. Conductor Size Compressed Stranded 1/0 or Compacted Solid 2/0. With Jacket Seal. With Test Point.

262LRJS-C5240C

25kV, 200 Amp, Elbow. LoadBreak. Bi-Metal Compression Lug. Cable Insulation Diameter 0.805 inch to 1.060 inch. Conductor Size Compressed Stranded 1/0 or Compacted Solid 2/0. With Jacket Seal. With Test Point.
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Compact/Solid Wire Size, Bi-Metal Compression Lug.

262LRJS-C5210

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Compact/Solid Wire Size, Bi-Metal Compression Lug.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

376LR-H-5230

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-2270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

375LR-K5250-SG3

35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

Frequently Asked Questions

What cable insulation diameters does this elbow support?

The elbow accommodates cable insulation diameters from 0.805 inch to 1.060 inch.

What conductor sizes are compatible with this elbow?

The elbow supports conductor sizes from AWG 4/0 compressed stranded to 250 mm² solid (126.67 mm² equivalent).

Does this elbow include a test point?

Yes, the elbow features an integrated test point for voltage verification.

What is the current rating of this elbow?

The current rating is 200 Amps.

What is the voltage rating of this elbow?

The voltage rating is 25kV.

Is this elbow suitable for loadbreak applications?

Yes, the elbow is designed for loadbreak applications, allowing safe energized connections and disconnections.

What material is used for the compression lug?

The compression lug is made of bi-metal (aluminum-to-copper) for corrosion resistance.

How to Install 261LRJS/262LRJS Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 261LRJS and 262LRJS Loadbreak Elbow Connectors with Jacket Seal on UD cable.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Crimp tool, Wire brush, Wire strippers, Hotstick

Supplies needed:

Lubricant, Mastic sealing strips, No. 14 AWG copper wire, Grounding connector, Vinyl tape

  1. Perform Pre-Installation Safety Checks

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all package contents and components for damage, proper rating, and compatibility with the cable and mating products. Verify threads by hand-threading the probe into the compression lug; replace damaged components if resistance is encountered. Gather all required tools and maintain a clean work area throughout the procedure.

  2. Train and Prepare the Cable Jacket

    Train the cable to ensure sufficient slack for future operation. Pull extra cable 24-26 inches beyond the bushing centerline and mark it. Remove the outer jacket 7-3/4 to 8 inches back from the tape mark. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline. Wrap one strip of mastic, stretching slightly, around the jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them firmly into the mastic. Wrap a second strip of mastic completely around the outer jacket, overlapping the imbedded neutral wires. Use a third strip if necessary to build up the outer diameter. Cover all mastic with vinyl tape.

  3. Prepare Cable Insulation and Install Compression Lug

    Remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the remaining insulation shield as shown in the template (6-7/8 inches). Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Assemble the Elbow Connector Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant only; DO NOT SUBSTITUTE other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.

  5. Connect the Concentric Neutral

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the copper wire tightly, taking care not to damage the grounding eye. Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the neutral wires for elbow operation.

  6. Prepare for Connection to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: Lubricate only if the transformer and elbow are known to be de-energized. Do not operate the connection by hand; use a hotstick as per operating instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.