ABB Installation Products 376LR-H-5230 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…
UPC: 783786622542
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 35kV rated loadbreak elbow connector
- Integrated test point for safe voltage verification
- Bi-metal compression lug supports AWG #1 to #1/0 conductors (42.41 mm²)
- Compatible with 0.850–1.050" cable insulation diameters
- Rugged design for harsh environments
Specifications
Amperage Rating | 200 A |
Application | 35 kv, 200 Amp |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | Compression |
Current Rating | 200A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal Compression Lug |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.850 inch to 1.050 inch |
Size | 0.850" - 1.050" |
Special Features | 35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Voltage Rating | 35kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.1000 L |
Package Weight (Metric) | 1.4060 kg |

375LR-J-5230
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
375LR-L-2270
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-K5250-SG3
35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.
375LR-K-5240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
375LR-K-5240-SG3
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, with Sealing Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
375LR-K5260-SG3
35kV, 200 Amp, Loadbreak Elbow with out Test Point, Cable Insulation Diameter 1.090 to 1.465 inches, Bi-Metal, Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
375LR-J5240-S
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. With Sealing Kit
375LR-J5250-SG3
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. With Sealing KitFrequently Asked Questions
What is the maximum voltage rating for this elbow connector?
The ABB 376LR-H-5230 loadbreak elbow connector has a maximum voltage rating of 35kV.
What is the current rating of the 376LR-H-5230 connector?
This loadbreak elbow connector is rated for 200 Amps.
What is the compatible cable insulation diameter range?
The connector is designed for cable insulation diameters ranging from 0.850 inches to 1.050 inches.
What type of lug does the 376LR-H-5230 use?
It features a bi-metal compression lug for secure and conductive connections.
What conductor sizes can be used with this connector?
It supports compressed stranded conductors from AWG #1 to #1/0, and solid conductors up to AWG #1/0 (42.41 mm²).
How to Install 375LR/376LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and preparation of 375LR and 376LR Loadbreak Elbow Connectors for UD cable termination, ensuring proper assembly and grounding.
Estimated time: 1h
Tools needed:
Probe Wrench, Wire brush, Crimp tool (refer to chart), Wire strippers, Hotstick
Supplies needed:
Lubricant (supplied, Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate grounding connector, Test point cap (for 376LR only)
- Perform Pre-Installation Checks and Safety Procedures
DANGER: De-energize all apparatus before beginning installation or removal of any part(s), except for test point caps and indicators. Inspect all components for damage, proper rating, and compatibility with mating parts. Verify the package contents are complete and undamaged. Check the threads by threading the probe into the compression lug; if resistance is encountered before full assembly, replace the damaged component. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.
- Prepare and Train the Cable
Train the cable as shown in the provided diagram to facilitate future operation, ensuring a minimum of 20 inches of cable extends beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.
- Prepare Cable End and Neutral Wires
Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor.
- Install and Crimp the Compression Lug
Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its CONTACT THREADED HOLE ALIGNS with the bushing bore. Crimp the lug according to the crimp chart (packaged with the lug), starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Finish Cable Insulation Preparation
Remove the insulation shield as indicated by the cable cut back template, and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring the surface is straight, smooth, and squared.
- Assemble the Elbow Connector Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect the Concentric Neutral Wires to Ground
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.
- Final Preparation for Connection (De-energized)
CAUTION: For 376LR models, lubricate the test point cap and assemble it tightly. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. WARNING: If the product was supplied with protective shipping cover(s), remove them and replace with the appropriate HV insulated cap(s) or connector(s) before submerging or energizing the circuit.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.