Contact for Pricing
Overview
- 25kV rated for medium-voltage applications
- 200 Amp continuous current rating
- Bi-metal compression lug for copper/aluminum compatibility
- Cable insulation diameter range: 0.805" to 1.060"
- LoadBreak design for safe connection/disconnection under load
- Integrated jacket seal for environmental protection
- Built-in test point for voltage verification
Specifications
Amperage Rating | 200 A |
Application | 200 kV, 200 Amp |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 11.47 in |
Material | Housing - EPDM-Rubber |
Special Features | 25kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in cable jacket seal. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point and Jacket Seal |
Voltage Rating | 28 kV |
Width | 8.2 in |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LR-E5230-SG2
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size #1 Stranded/Compressed, 1/0 Solid/Compact. With Test Point. 200ECS-G2 Jacket Seal and Grounding Kit Included. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LRJS-C5240C
25kV, 200 Amp, Elbow. LoadBreak. Bi-Metal Compression Lug. Cable Insulation Diameter 0.805 inch to 1.060 inch. Conductor Size Compressed Stranded 1/0 or Compacted Solid 2/0. With Jacket Seal. With Test Point.
262LRJS-C5210
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Compact/Solid Wire Size, Bi-Metal Compression Lug.
376LR-H-5230
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
375LR-L-2270
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
375LR-K5250-SG3
35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.
375LR-K-5240
35kV 200 Amp, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.Frequently Asked Questions
What standards does the elbow meet?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and ANSI certified.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Does the elbow have RUS acceptance?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced Elastimold 200 amp loadbreak elbow, available for 15 kV and 25 kV series, designed for easier switching.
What standards does the elbow meet?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and ANSI certified.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Does the elbow have RUS acceptance?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced Elastimold 200 amp loadbreak elbow, available for 15 kV and 25 kV series, designed for easier switching.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced Elastimold 200 amp loadbreak elbow, available for 15 kV and 25 kV series, designed for easier switching.
How to Install the 262LRJS Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and preparation of the 262LRJS Loadbreak Elbow Connector with Jacket Seal for UD cable, including cable training, preparation, and assembly.
Estimated time: 1h
Tools needed:
Probe wrench, Crimp tool, Wire brush, Cable cut back template, Wire strippers, Cable cutter, Vinyl tape
Supplies needed:
262LRJS Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Mastic sealing strips (3), Copper wire (No. 14 AWG / 2.5mm), Grounding connector, UD cable, Insulated cap(s) or connector(s)
- Perform Pre-Installation Checks and Safety Procedures
DANGER: Ensure all apparatus is de-energized during installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Check the package contents to ensure they are complete and undamaged. Verify all components fit properly with the cable and/or mating products. Check the probe threads by threading the probe into the compression lug; if resistance is encountered, replace damaged components. If the test point cap is not installed, lubricate the cap and test point, then install the cap.
- Train and Prepare the Cable
Train the UD cable to ensure sufficient slack for ease of operation. Pull extra cable 24 to 26 inches beyond the centerline of the bushing. Place a tape mark at the bushing centerline. Remove the outer jacket 7-3/4 to 8 inches back from the tape mark. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline.
- Prepare the Cable End with Mastic and Lug
Wrap one strip of mastic, stretching slightly, around the cable jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them firmly into the mastic. Wrap the second strip of mastic completely around the outer jacket, overlapping the imbedded neutral wires. Use the third strip of mastic if needed to build up the outer diameter. Cover all mastic with vinyl tape. Remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as indicated by the cable cut back template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends.
- Connect the Concentric Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Pull the hood over the concentric neutral seal area on the cable by pulling the tabs and/or rolling the seal down. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation.
- Prepare for Final Connection to Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. WARNING: Only lubricate if the transformer and elbow are KNOWN TO BE DE-ENERGIZED. Once lubricated and confirmed de-energized, the elbow is ready for connection to the bushing plug using appropriate operating tools as per safety guidelines; do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.