ABB Installation Products 262LR-E5260 25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310…
UPC: 075114312226
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV rated for medium-voltage applications
- 200-amp continuous current capacity
- Bi-metal conductor compatibility (3/0 stranded/compressed, 4/0 solid/compact)
- Cable insulation diameter range: 1.090-1.310 inches (27.69-33.27 mm)
- Test point for safe voltage verification
- Includes compression lug, probe, wrench, lubricant, and crimp chart
- No sealing kit included for application-specific customization
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Connection Type | Loadbreak Elbow |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | Cable Insulation Diameter 1.090-1.310 inches, |
Size | Cable Insulation Diameter 1.090-1.310 inches (27.69-33.27 mm) |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

375LR-K5260-SG3
35kV, 200 Amp, Loadbreak Elbow with out Test Point, Cable Insulation Diameter 1.090 to 1.465 inches, Bi-Metal, Conductor Size 260 - 3/0 Stranded/Compressed or 4/0 Solid/Compact. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring
262LRJS-E5240
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LR-E5270
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
167LRT-F5220-SG3
15kV, 200 Amps, Loadbreak, Elbow-T, with Sealing Kit, Cable Insulation Diameter .640- .820 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact.
167LRT-G5220-SG3
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2 or Solid/Compact #1. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.
756LR-M0270
35kV, 600 Amp, Deadbreak Elbow, Cable Insulation Diameter 1.370 - 1.630 inches, Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid/Compact 250, No Sealing Kit
261LR-B5220-S
25/28kV, 200 Amp, Elbow Connector, Loadbreak, with Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.Frequently Asked Questions
What conductor sizes does this elbow support?
This elbow supports 3/0 stranded/compressed and 4/0 solid/compact conductors.
Is a test point included with this elbow?
Yes, the ABB 262LR-E5260 includes a test point for voltage verification.
What components are included in the kit?
The kit includes the elbow connector housing, compression lug, probe, probe wrench, lubricant, installation instruction sheet, and crimp chart.
What is the maximum operating voltage for this elbow?
The ABB 262LR-E5260 is rated for 25kV maximum operating voltage.
What is the cable insulation diameter range?
The cable insulation diameter range is 1.090 to 1.310 inches (27.69 to 33.27 mm).
What is the current rating of this elbow?
The ABB 262LR-E5260 has a 200-amp continuous current rating.
Does this elbow include a sealing kit?
No, this elbow does not include a sealing kit. It is designed for application-specific sealing solutions.
Is this elbow suitable for underground applications?
Yes, this elbow is designed for underground distribution systems and similar applications.
How to Install the 262LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, including cable preparation, assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Wire strippers, Cable cutting tool, Hotstick tool
Supplies needed:
Lubricant (supplied with kit, do not substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector (for neutral wires), Vinyl tape (if using jacketed cable with drain wires), Conductive copper tape (if using 200ECS-G2 kit), Cold shrink tube (if using 200ECS, 200ECS-G1, or 200ECS-G2 sealing kits)
- Safety First: De-energize Apparatus and Inspect Components
DANGER: Confirm that all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect the contents of the package to ensure all parts (Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant) are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Verify the probe threads by threading the probe into the compression lug; if resistance is encountered before full assembly, check for damage and replace the component.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack for ease of future operation. Based on your specific cable type (e.g., concentric neutral, jacketed with drain wires, copper tape shield), refer to the document's Step 1 for detailed instructions on managing neutral/grounding wires and removing the outer jacket/shield. Cut the excess cable squarely at the centerline of the bushing. Remove the insulation shield and insulation 2-1/8” (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Remove the insulation shield 6-7/8” (175mm) back from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end 1/8” (5mm) maximum.
- Install the Compression Lug
Thoroughly wire brush the bare aluminum conductors to ensure a clean connection. Immediately install the compression lug onto the prepared conductor. Rotate the lug to spread any inhibitor. Position the compression lug so that the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Thoroughly clean the cable insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Maintain cleanliness of the insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion until it is fully seated. Wipe off all excess lubricant from the exterior of the assembly. Align the elbow connector with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly around the grounding eye, taking care not to damage the eye. Twist all neutral wires together and connect them to the ground wire using an appropriate connector. Ensure adequate slack is provided in the grounding and neutral wires to allow for future elbow operation. If using a cold shrink grounding kit, refer to the specific instructions supplied with that kit to complete the grounding process.
- Prepare for Connection to Bushing
DANGER: Re-confirm that the transformer and the mating bushing are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied in the kit. DO NOT OPERATE (connect) by hand. Use a full insulated "hotstick" type tool for connection, following the operating instructions for loadmake operation when ready to energize.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.