ABB - Installation Products 756LR-M0270 - 35kV, 600 Amp, Deadbreak Elbow, Cable Insulation Diameter 1.370 - 1.630 inches, Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid/Compact 250, No Sealing Kit

ABB Installation Products 756LR-M0270 35kV, 600 Amp, Deadbreak Elbow, Cable Insulation Diameter 1.370 - 1.630 inches, Aluminum…

UPC: 075114320603


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 756LR-M0270 Deadbreak Elbow is a fully shielded, submersible cable connector engineered for 35kV medium-voltage applications requiring a 600 Amp continuous rating. This deadbreak design ensures safe, dead-front connections in underground distribution systems, substations, and other high-voltage environments where environmental sealing and electrical safety are critical. The molded rubber housing is 100% peroxide-cured EPDM, providing exceptional dielectric strength, ozone resistance, and long-term reliability in harsh conditions. This elbow accommodates cable insulation diameters from 1.370 to 1.630 inches, making it compatible with a defined range of medium-voltage cables. The integrated aluminum compression lug supports 4/0 AWG compressed/stranded conductors or 250 AWG solid/compact conductors, delivering robust mechanical strength and excellent electrical conductivity for stable, low-resistance connections. Key applications include: - Underground distribution systems - Substations and switchgear - Pad-mounted transformers - Cable terminations in wet or corrosive environments The deadbreak design allows for safe connection and disconnection under de-energized conditions using standard hand tools, eliminating the need for specialized equipment. While this product does not include a sealing kit, it is designed for use with compatible accessories for grounding, testing, and isolation when required. The 756LR-M0270 is part of ABB's Installation Products catalog, a trusted line of electrical infrastructure solutions for medium-voltage applications.
  • 35kV voltage class with 600 Amp continuous rating
  • Accommodates cable insulation diameters from 1.370 to 1.630 inches
  • Supports 4/0 AWG compressed/stranded or 250 AWG solid/compact conductors
  • Fully shielded, submersible molded rubber housing (EPDM)
  • Meets ANSI/IEEE Standard 386 for medium-voltage applications

Specifications

Amperage Rating
600 A
Application
35 kv, 600 Amp
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Deadbreak Elbow
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Aluminum
Series
756LR-M0270
Size
Cable Insulation Diameter 1.370 - 1.630 inches
Special Features
35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-M0270-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25/28kV, 200 Amp, Elbow Connector, Loadbreak, with Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.

261LR-B5220-S

25/28kV, 200 Amp, Elbow Connector, Loadbreak, with Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.
35kV, 600 Amp, Deadbreak Elbow, with Test Point, includes Insulated Plug, Cap, Stud, Lug and Cable Adapter. No Sealing Kit. Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 500 Stranded/Compressed.

756LR-L0330

35kV, 600 Amp, Deadbreak Elbow, with Test Point, includes Insulated Plug, Cap, Stud, Lug and Cable Adapter. No Sealing Kit. Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 500 Stranded/Compressed.
25/28kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .805-1.060 inches, Bi-Medal Lug, Conductor Size 4/0 AWG Stranded Compressed or 250 kcmils Compact/Solid. With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

261LR-C5270-SG3

25/28kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .805-1.060 inches, Bi-Medal Lug, Conductor Size 4/0 AWG Stranded Compressed or 250 kcmils Compact/Solid. With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

756LR-P0380-SG3

15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .805-1.060 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-C5220

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .805-1.060 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LRJS-C5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

Frequently Asked Questions

What is the primary application of the 756LR?

The 756LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What is the impulse withstand rating (BIL) for the 756LR?

The impulse withstand (BIL) rating for the 756LR is 150kV.

How is the 756LR connected or disconnected?

It can be easily connected or disconnected using standard hand tools and equipment in a de-energized state.

What materials are used in the 756LR construction?

It features 100% peroxide-cured construction, including insulation and conductive EPDM materials.

Is the 756LR submersible?

Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.

What standard does the 756LR meet?

The 756LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the 756LR?

The continuous current rating of the 756LR is 600 Amps.

What is the maximum operating voltage for the 756LR?

The maximum phase-to-ground operating voltage for the 35kV voltage class is 21.1kV.

What insulation diameters does the 756LR support?

It supports insulation diameters from 0.760 inches to 2.120 inches.

What is the conductor size range for the 756LR?

The conductor range for the 756LR is from #2 AWG to 1250 kcmil.

How to Install 756LR/776LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 756LR and 776LR Deadbreak Elbow Connectors on 35kV class systems, including cable preparation, component assembly, grounding, and post-installation voltage testing.

Estimated time: 1h 30m

Tools needed:

Cutting tool, Wire strippers, Wire brush, Crimping tool, Torque wrench, Hotstick, Suitable sensing device for capacitive test points

Supplies needed:

Cable, Grounding device (e.g., 20MA or 21MA), Wire (at least No. 14 AWG Copper), HV insulated cap(s) or connector(s), Silicone lubricant, Waterproofing material, 756LR or 776LR Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Crimp connector, Lubricant, Stud Prepack)

  1. De-energize and Inspect Components

    DANGER: Ensure all apparatus is de-energized during installation or removal. Do not touch or move energized products. Inspect the elbow, cable adapter, compression lug, and mating parts for damage, correct rating, and compatibility. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit.

  2. Position and Clean Cable Jacket

    Position the cable so it is located in the final assembled position with enough slack to provide adequate clearance for removing the elbows. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24” (610mm).

  3. Prepare Cable Insulation and Shield

    Prepare the cable end by removing the outer jacket (where applicable) and shield as shown in the specific cable preparation diagrams (e.g., non-jacketed concentric neutral, jacketed shield wires, flat metallic tape shield, fabric tape shield, or longitudinally corrugated shield). Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back.

  4. Clean, Lubricate, and Install Cable Adapter

    Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  5. Prepare Conductor and Crimp Compression Lug

    Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Do not cut or nick the cable adapter or the conductor. The length of exposed conductor should be between 4-3/8” to 4-3/4” (111mm-121mm). For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor and immediately fully insert it. Measure the “Check Dimension” before crimping (should be less than 7” or 178mm). Crimp the compression lug following its supplied instructions. Wipe all excess inhibitor from the lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be between 6-7/8” to 7-5/8” (175mm-194mm).

  6. Lubricate and Install Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter until the elbow cannot advance further. Make sure the cable adapter is still flush with the tape marker. If not, reposition the cable adapter. Remove the tape marker.

  7. Connect Elbow to Apparatus Bushing

    DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Hand tighten the threaded stud supplied with the elbow into the mating part, if the mating part is not equipped with a stud. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part, lining up the hole in the compression lug with the stud on the mating part.

  8. Connect Second Mating Product (if applicable)

    If connecting a second mating product to the opposite end of the elbow, clean and lubricate it. Insert the mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that mating part.

  9. Install Insulating Plug or Voltage Detection Cap

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps into place. This insulating plug provides a means for detecting system voltage.

  10. Ground the Cable Shield and Waterproof Jacket

    Insert one end of a piece of wire with ampacity at least equivalent to No. 14 AWG Copper through the grounding eye and twist to make a small loop. Do not damage the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded according to the instructions supplied with the grounding device or through an alternate method. It is also recommended that the jacket of the cable be waterproofed at this point to prevent moisture from entering the cable.

  11. Perform Voltage Test Using Capacitive Test Point

    CAUTION: The voltage test point is a capacitance device, not directly connected to the conductor. Remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.