ABB - Installation Products 168RLR-K-5260 - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

ABB Installation Products 168RLR-K-5260 200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation…

UPC: 783786834600


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168RLR-K-5260 is a 200 Amp, 15kV loadbreak replacement elbow connector designed for medium-voltage cable systems. This connector accommodates cable insulation diameters from 1.090 inch to 1.310 inch and supports conductor sizes ranging from AWG compressed stranded 3/0 to solid 4/0, as well as 85.01 mm². The extended length contact and elbow housing provide an additional 8-7/8 inches of length, improving installation flexibility and safety in confined spaces. The bi-metal compression lug ensures reliable electrical contact and mechanical strength across a wide range of conductor types. Included with the connector is the 00400X long bi-metal contact, which enhances durability and reduces the risk of arcing or overheating. This replacement elbow is engineered for use in loadbreak applications where temporary disconnection under load is required, such as in utility substations, industrial power distribution, and renewable energy installations. The 15kV rating makes it suitable for medium-voltage systems, while the loadbreak feature allows for safe, hot-stick operation without interrupting service. The connector’s design aligns with industry standards for medium-voltage elbow connectors, ensuring compatibility with existing infrastructure. For maintenance teams, this product reduces downtime by providing a dependable, field-replaceable solution for damaged or worn elbows.
  • 200 Amp, 15kV loadbreak replacement elbow connector
  • Cable insulation diameter range: 1.090" to 1.310"
  • Conductor size support: AWG compressed stranded 3/0 / solid 4/0 / 85.01 mm²
  • Extended length contact and housing for 8-7/8" net gain in length
  • Includes 00400X long bi-metal contact for enhanced durability

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
168RLR
Size
Cable Insulation Diameter 1.090 inch to 1.310 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 10-1/2 inch (266.7mm). Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Bi-Metal Compression lug.

274ELR-88110-5260

25kV 200 Amp, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. Bi-Metal Compression lug.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.

K151SR-C0260

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.

K151SR-A0250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

376LR-L-5270-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.

167RLR-G5230-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

K151SP-C2250

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

274ELR-88110-5250

200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the current rating of the elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

What voltage classes do these connectors support?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

How much length does the repair elbow add?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

How much length does the replacement elbow add?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

What material are the elbows constructed from?

The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

Are these elbow connectors certified?

Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.

What is the test point cap catalog number?

The test point cap catalog number for elbows with a test point is 156-7.

Does this elbow connector include a test point?

Yes, the 168RLR replacement elbow connector includes a built-in capacitive test point to allow testing of the circuit for the presence of voltage.

Where are these elbow connectors manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, New Mexico, USA.

How to Install the 168RLR Loadbreak Replacement Elbow Connector

This guide details the installation of the 168RLR Loadbreak Replacement Elbow Connector, converting a livefront termination to deadfront for UD cable. It provides an operating interface for connecting to 15kV class loadbreak bushings or accessory devices.

Estimated time: 1h 30m

Tools needed:

Cable cutter, Cable insulation stripper, Wire brush, Crimping tool, Probe wrench, Screwdriver, Hotstick, Suitable capacitive voltage sensing device

Supplies needed:

168RLR Replacement Elbow Connector Kit (Housing, Lug, Probe, Lubricant, Hose Clamp), No. 14 AWG (2.5mm) copper wire, Grounding connector, Silicone grease

  1. De-energize Apparatus and Remove Existing Livefront Terminator

    DANGER: Ensure all apparatus is de-energized during installation or removal of parts. Remove the rubber cap from the terminator, cut off the connector at the top, disconnect the ground lead from the base, and then remove the terminator housing from the cable.

  2. Prepare the Cable

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. If the insulation shield measures less than 6-1/2 inches, proceed; otherwise, consult an ELASTIMOLD representative. Carefully remove 1-3/8 inches of cable insulation from the end, ensuring a square cut and avoiding nicks to the conductor.

  3. Install the Compression Lug

    Wire brush the bare aluminum conductor. Immediately install the compression lug, rotating it to spread the inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor from the lug and cable.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for about four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  5. Connect the Concentric Neutral

    Insert one end of a No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tightly. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. Add the hose clamp as shown and tighten it snugly, but do not overtighten.

  6. Lubricate and Prepare for Connection

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Do not operate by hand.

  7. Connect the Elbow to the Bushing

    Using a hotstick tool, remove the insulated cap from the bushing. Securely fasten the hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle over the bushing plug, inserting the male contact until slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface.

  8. Perform Voltage Test (168RLR Only)

    Using a hotstick, remove the test point cap by peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable capacitive sensing device (not conventional voltage equipment) to determine if the cable is energized, following the device manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.