ABB Installation Products 261LR-B5220-S 25/28kV, 200 Amp, Elbow Connector, Loadbreak, with Sealing Kit, No Test Point, Cable…
UPC: 075114321082
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated 25/28kV, 200 Amp for underground distribution systems
- Bi-metal lug compatible with #2 stranded/compressed or #1 compact/solid conductors
- Cable insulation diameter range: 0.635 to 0.905 inches
- Loadbreak design for safe connection/disconnection under load
- Includes sealing kit for IP68 environmental protection; no test point
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 25/28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter .635-.905 inches |
Special Features | 25/28kV, 200 Amp Loadbreak Elbow. Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 25 to 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
756LR-L0330
35kV, 600 Amp, Deadbreak Elbow, with Test Point, includes Insulated Plug, Cap, Stud, Lug and Cable Adapter. No Sealing Kit. Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 500 Stranded/Compressed.
261LR-C5270-SG3
25/28kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .805-1.060 inches, Bi-Medal Lug, Conductor Size 4/0 AWG Stranded Compressed or 250 kcmils Compact/Solid. With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
756LR-P0380-SG3
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
252LR-C5220
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .805-1.060 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
252LRJS-C5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
376LR-J2240
35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.
252LR-B5220
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .635-.905 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.Frequently Asked Questions
Is this product approved for rural infrastructure?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
Is an integral jacket seal available for the elbow?
Yes, an optional integral jacket seal is available for the enhanced Elastimold 200 amp loadbreak elbow.
What material is the pulling eye made of?
The pulling eye is made of robust stainless steel, promoting durable hotstick control.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What certifications does the loadbreak elbow have?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has RUS acceptance from the USDA.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV applications.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What certifications does the loadbreak elbow have?
The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has RUS acceptance from the USDA.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV applications.
What material is the pulling eye made of?
The pulling eye is made of robust stainless steel, promoting durable hotstick control.
How to Install 261LR/262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial setup of 261LR and 262LR Loadbreak Elbow Connectors, including cable preparation, lug attachment, elbow assembly, and grounding.
Estimated time: 45m
Tools needed:
Wire brush, Crimp tool, Probe wrench, Hotstick tool, Cable strippers/knife, Vinyl tape
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), UD cable, Copper wire (No. 14 AWG / 2.5mm), Grounding connector, Cold shrink tube (optional), Conductive copper tape (optional)
- Ensure Safety and Inspect Components
Before beginning, ensure all apparatus are de-energized. Inspect the contents of the package to confirm all parts (Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant) are present, undamaged, and compatible with your cable and mating products. Read the entire installation instructions.
- Prepare the Cable
Train the cable to ensure adequate slack for operation. Depending on your cable type (non-jacketed/jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the documentation for removing the outer jacket and shield to the specified lengths (e.g., 9-5/8 inches for jacket, 7-1/8 inches for copper tape shield). Cut the cable squarely at the bushing centerline. Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a straight, smooth, and squared cut without nicking the conductor. Bevel the insulation end a maximum of 1/8 inch (5mm).
- Install the Compression Lug
Thoroughly wire brush the bare aluminum conductors immediately after preparing the cable. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Finally, thoroughly clean the cable insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect the Elbow to the Bushing
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.