ABB Installation Products 262LR-E5250-SG2 25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches…
UPC: 075114312219
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV, 200 Amp-rated loadbreak elbow connector for medium-voltage systems
- Bi-metal conductor supports conductor sizes from 20 AWG stranded/compressed to 3/0 AWG solid/compact
- Accommodates cable insulation diameters between 1.090 and 1.310 inches (27.69-33.27 mm)
- Integrated test point for safe voltage testing and system diagnostics
- Includes 200ECS-G2 Jacket Seal and Grounding Kit with all necessary installation accessories
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 28kV class, 200 Amp Distribution Apparatus |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 1.090-1.310 inches, |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

261LRJS-C5240
25/28kV, 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-E5260
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 3/0 Stranded/Compressed, 4/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LRJS-E5240
25kV, 200 Amps, Loadbreak Elbow, Built in Jacket Seal, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 1/0 Stranded/Compressed, 2/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
262LR-E5270
25kV, 200 Amps, Loadbreak Elbow, no Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 4/0 Stranded/Compressed, 250 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installion Instruction Sheet and Crimp Chart.
167LRT-F5220-SG3
15kV, 200 Amps, Loadbreak, Elbow-T, with Sealing Kit, Cable Insulation Diameter .640- .820 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact.
167LRT-G5220-SG3
200 Amp, 15kV, Loadbreak Bolted Elbow with Tap, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2 or Solid/Compact #1. 200ECS-G3 Jacket Seal and Grounding Kit Included. Includes 02800X Bi-Metal Contact.
756LR-M0270
35kV, 600 Amp, Deadbreak Elbow, Cable Insulation Diameter 1.370 - 1.630 inches, Aluminum Compression Lug. Conductor Size AWG Compressed/Stranded 4/0 or Solid/Compact 250, No Sealing Kit
261LR-B5220-S
25/28kV, 200 Amp, Elbow Connector, Loadbreak, with Sealing Kit, No Test Point, Cable Insulation Diameter .635-.905 inches, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid.Frequently Asked Questions
What is the maximum voltage rating for this loadbreak elbow?
The ABB 262LR-E5250-SG2 loadbreak elbow connector has a maximum voltage rating of 25 kV.
What is the current carrying capacity of this connector?
This loadbreak elbow connector is rated for 200 Amps.
What cable insulation diameters does this elbow connector fit?
The connector is designed for cable insulation diameters ranging from 1.090 to 1.310 inches (27.69 to 33.27 mm).
What type of conductor material is used in this elbow connector?
This ABB loadbreak elbow connector features a bi-metal conductor.
Does this connector include a grounding kit?
Yes, the 262LR-E5250-SG2 includes the 200ECS-G2 Jacket Seal and Grounding Kit.
What conductor sizes are compatible with this elbow connector?
It is compatible with 20/Stranded/Compressed and 3/0 Solid/Compact conductor sizes.
Does the connector have a test point?
Yes, this loadbreak elbow connector is equipped with a test point for diagnostics.
How to Install the 262LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, including cable preparation, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Hotstick tool
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral connector
- Perform Initial Safety Checks and Component Inspection
Before starting, ensure all apparatus is de-energized. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Read all instructions thoroughly and have required tools ready. Do not touch or move energized products in the work area.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the manual for preparing neutral wires, removing the outer jacket, and cutting the cable squarely at the bushing centerline. Ensure proper dimensions are met for shield and jacket removal.
- Prepare Cable End and Install Compression Lug
Remove the insulation shield and insulation 2-1/8” (55mm) squarely from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread inhibitor, ensuring the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor.
- Final Cable Insulation Preparation
Remove the insulation shield 6-7/8” (175mm) from the cable end. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor, ensuring a straight, smooth, and squared surface.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist it tightly, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation.
- Connect the Elbow to the Bushing Plug
DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.