ABB - Installation Products 262LR-D5220-SG3 - 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.
More images

ABB Installation Products 262LR-D5220-SG3 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to…

UPC: 075114192231


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-D5220-SG3 is a 200 Amp, 25kV loadbreak elbow connector designed for underground distribution systems. This elbow includes a test point for safe voltage verification and a bi-metal compression lug compatible with compressed stranded #2 AWG or solid #1 AWG conductors (33.62 mm² cross-section). The integrated 200ECS-G3 jacket seal and grounding kit ensures environmental protection and grounding integrity in medium-voltage applications. This loadbreak elbow is rated for cable insulation diameters between 0.890 inch and 1.220 inch, making it suitable for standard underground residential and commercial distribution cables. The bi-metal compression lug provides reliable conductivity and mechanical strength, while the grounding kit enables proper fault current dissipation. The test point allows for non-intrusive voltage detection without disconnecting the elbow, improving operational safety and maintenance efficiency. Common applications include pad-mounted transformers, switchgear, and underground vaults where loadbreak operations are required. The elbow’s design meets ANSI C119.4 and IEEE 386 standards for loadbreak separable connectors, ensuring compatibility with industry-standard equipment. The included grounding kit simplifies installation by bundling critical components, reducing procurement steps and potential errors.
  • 200 Amp, 25kV loadbreak elbow with test point for voltage verification
  • Bi-metal compression lug compatible with #2/AWG compressed stranded or #1/AWG solid conductors (33.62 mm²)
  • Cable insulation diameter range: 0.890 inch to 1.220 inch
  • Includes 200ECS-G3 jacket seal and grounding kit for environmental protection and grounding
  • Meets ANSI C119.4 and IEEE 386 standards for loadbreak separable connectors

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Size
0.890 inch - 1.220 inch
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5220

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5230

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.

262LR-D5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.

262LR-D5260-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5240-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LRJS-C5220

28kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

Frequently Asked Questions

What is the current rating of the elbow?

The product is a 200 amp loadbreak elbow.

What is the purpose of rigid probe support?

The rigid probe support ensures proper switching and easy probe installation.

What material is the pulling eye made from?

The pulling eye is made from robust stainless steel, promoting durable hotstick control.

Does the elbow feature a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards does the elbow comply with?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant and has ANSI certification.

Is the enhanced Elastimold elbow RUS accepted?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What safety features does the enhanced elbow offer?

It includes improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What are the voltage ratings for this elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available for 15 kV and 25 kV series, designed for switching operations.

What is the current rating of the elbow?

The product is a 200 amp loadbreak elbow.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for preparing the cable, assembling the 262LR Loadbreak Elbow Connector, and connecting it to a 25kV class loadbreak bushing or accessory device.

Estimated time: 1h

Tools needed:

Probe Wrench, Wire strippers, Wire brush, Crimp tool (refer to lug chart), Hotstick (for energized operation), Pliers

Supplies needed:

262LR Elbow Connector Kit (Housing, Lug, Probe, Lubricant), UD Cable (appropriate type), Copper ground wire (No. 14 AWG / 2.5mm, if not preordered), Neutral wire connector, Cold shrink tube/kit (if applicable), Vinyl tape (if applicable), Mating 25kV class loadbreak bushing or accessory, Insulation cleaning solution

  1. Prepare Cable for Termination

    Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), prepare the neutral or drain wires, cut the cable squarely at the bushing centerline, and remove the outer jacket and/or copper tape shield as specified in the documentation. If using a cold shrink kit, slide the tube onto the cable now.

  2. Prepare Cable End and Install Compression Lug

    Remove 2-1/8” (55mm) of the shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's chart. Carefully wipe off excess inhibitor. Remove 6-7/8” (175mm) of the insulation shield and bevel the insulation end 1/8” (5mm) maximum. Thoroughly clean the insulation.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  4. Connect Grounding Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.

  5. Connect Elbow to Mating Bushing

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.