ABB - Installation Products 262LR-C5260-S - 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
More images

ABB Installation Products 262LR-C5260-S 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to…

UPC: 075114192170


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-C5260-S is a 200 Amp, 25kV loadbreak elbow connector designed for medium-voltage cable systems. This bi-metal compression lug accommodates compressed stranded AWG 3/0, solid AWG 4/0, or 85.01 mm² conductors with cable insulation diameters between 0.805 and 1.060 inches. The integrated test point enables safe voltage detection without interrupting service, while the included 200ECS jacket seal provides environmental protection against moisture and contaminants. This elbow is rated for 25kV class systems, making it suitable for underground distribution networks, pad-mounted transformers, and switchgear applications. The bi-metal construction ensures compatibility with both copper and aluminum conductors, reducing the need for additional adapters. Installation requires standard compression tools and follows ABB’s proven loadbreak elbow standards for reliable, field-proven performance. The 262LR-C5260-S is part of ABB’s Installation Products catalog, a trusted line for utility and industrial electrical infrastructure.
  • 200 Amp, 25kV loadbreak elbow connector
  • Bi-metal compression lug for AWG 3/0 stranded, AWG 4/0 solid, or 85.01 mm² conductors
  • Cable insulation diameter range: 0.805" to 1.060"
  • Integrated test point for safe voltage detection
  • Includes 200ECS jacket seal for environmental protection

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Housing - EPDM-Rubber
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.

262LR-D5260-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-C5270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5220

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5220-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS-G3 Jacket Seal and Grounding Kit Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5230

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.

262LR-D5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, Wire Size 1/0 Stranded or 2/0 Solid. Bi-Metal Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-D5270

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

262LR-D5240-SG3

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

Frequently Asked Questions

What certifications does the Elastimold elbow hold?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What safety features are included in the enhanced elbow?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What is the primary function and rating of this product?

The product is an enhanced 200 amp loadbreak elbow, designed for 15 kV and 25 kV applications. It is optimized for switching operations.

What certifications does the Elastimold elbow hold?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What safety features are included in the enhanced elbow?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What is the primary function and rating of this product?

The product is an enhanced 200 amp loadbreak elbow, designed for 15 kV and 25 kV applications. It is optimized for switching operations.

What certifications does the Elastimold elbow hold?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What safety features are included in the enhanced elbow?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What is the primary function and rating of this product?

The product is an enhanced 200 amp loadbreak elbow, designed for 15 kV and 25 kV applications. It is optimized for switching operations.

What safety features are included in the enhanced elbow?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for preparing the cable, assembling the 262LR Loadbreak Elbow Connector, and making the initial connection to a de-energized bushing.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Crimp tool (specific to lug), Wire brush, Cable cutting tool, Wire strippers, Hotstick

Supplies needed:

262LR Elbow Connector Kit (Housing, Compression Lug, Probe, Lubricant), No. 14 AWG (2.5mm) copper wire, Neutral wire connector, Cold shrink tube (if applicable)

  1. Perform Initial Safety Checks and Component Verification

    DANGER: All apparatus must be de-energized during installation or removal of part(s) to prevent serious or fatal injury. Before beginning, inspect all components from the 262LR kit for any damage, verify their ratings, and confirm compatibility with the mating bushing and cable. Check the package contents against the list provided. Thread the probe into the compression lug by hand to ensure it turns freely without resistance, indicating no thread damage. Gather all necessary tools and maintain a clean work area throughout the installation.

  2. Prepare the Cable and Install the Compression Lug

    Train the cable to ensure sufficient slack for future operation. For jacketed concentric neutral cable, pull 24-26 inches (610-660mm) of extra cable beyond the bushing centerline and mark it. Remove 9-5/8 inches (240mm) of the outer jacket from this mark, then unwrap the neutral wires past the bushing centerline. Cut the cable end squarely at the bushing centerline. Remove 2-1/8 inches (55mm) of the insulation shield and primary insulation from the cable end, taking care not to nick the conductor. Wire brush the bare aluminum conductor and immediately install the compression lug, rotating it to spread the inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug using the recommended tool and chart, starting at the crimp line and rotating 180 degrees for each successive crimp. Wipe off any excess inhibitor. Finally, remove 6-7/8 inches (175mm) of the remaining insulation shield and bevel the primary insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation surface.

  3. Assemble the Elbow and Install the Probe

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may harm the product. Slide the elbow connector onto the cable using a back-and-forth twisting motion until it is fully seated. Wipe off any excess lubricant. Align the elbow's operating eye with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  4. Make Grounding Connections

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions for completion.

  5. Connect the Elbow to the Bushing

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with the connection. Do not operate by hand. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.