Authorized ABB Distributor (Installation Products)
ABB - Installation Products 262LR-C5230-SG3 - 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. 200ECS-G3 Jacket Seal and Grounding Kit Included.
More images

ABB Installation Products 262LR-C5230-SG3 200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to…

UPC: 075114192088


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 262LR-C5230-SG3 is a 200 Amp, 25kV loadbreak elbow connector engineered for reliable medium-voltage electrical connections in industrial and utility applications. Designed to accommodate cable insulation diameters from 0.805 inches to 1.060 inches, it supports a broad range of conductor sizes, including compressed stranded AWG #1 to #1/0 and solid AWG #1/0, with a corresponding mm² size of 42.41 mm². The connector features a bi-metal compression lug, enabling compatibility with both stranded copper and aluminum conductors, which is critical for mixed-material installations. The included 200ECS-G3 jacket seal and grounding kit provides a complete installation package, ensuring watertight and corrosion-resistant performance. This product is part of ABB’s Installation Products catalog, known for high-quality electrical infrastructure solutions. Key applications include medium-voltage switchgear, transformers, and cable terminations in power distribution systems. The loadbreak design allows for safe connection and disconnection under load, reducing downtime during maintenance. The bi-metal lug ensures long-term reliability by preventing galvanic corrosion between dissimilar metals. The integrated test point simplifies voltage verification, enhancing operational safety and efficiency.
  • 200 Amp, 25kV rated loadbreak elbow connector for medium-voltage applications
  • Integrated test point for safe voltage verification during maintenance
  • Accommodates cable insulation diameters from 0.805" to 1.060"
  • Bi-metal compression lug compatible with stranded copper and aluminum conductors
  • Includes 200ECS-G3 jacket seal and grounding kit for complete installation

Specifications

Amperage Rating
200 A
Application
200 kV, 200 Amp
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
262LR
Size
9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter
Size
Cable Insulation Diameter 0.805 inch to 1.060 inch
Special Features
28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
28 kV
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.6500 L
Package Weight (Metric)
1.2020 kg
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.

755LR-H0230

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50.
28kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-C5220

28kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.

262LR-C5220-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-C5210

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug

162LR-D5270

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug.

262LR-C2220

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug.
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.

262LR-B5240

25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.

262LR-C5210-S

200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.

Frequently Asked Questions

What is the maximum cable insulation diameter for this elbow?

The ABB 262LR-C5230-SG3 loadbreak elbow is designed to fit cable insulation diameters ranging from 0.805 inch to 1.060 inch.

What conductor sizes can the bi-metal lug accommodate?

The bi-metal compression lug supports compressed stranded conductor sizes from AWG #1 up to AWG #1/0, and solid conductor sizes up to AWG #1/0 (42.41 mm²).

Does this loadbreak elbow include a grounding kit?

Yes, the 262LR-C5230-SG3 comes with the 200ECS-G3 jacket seal and grounding kit included.

What is the voltage rating of this ABB loadbreak elbow?

The ABB 262LR-C5230-SG3 loadbreak elbow has a voltage rating of 25kV.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, designed for terminating various UD cables and connecting to 25kV class loadbreak bushings.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp tool (for compression lug), Wire brush, Hotstick, Suitable sensing device (for capacitive test points), Wire strippers/Cable knife, Measuring tape/Ruler

Supplies needed:

262LR Loadbreak Elbow Connector kit (includes Housing, Compression Lug, Probe, Lubricant), UD Cable (to be terminated), Grounding braid wire or jumper (if required), Cold shrink tube (if using a sealing kit), Copper wire (No. 14 AWG / 2.5mm or equivalent) for grounding, Appropriate connector (for neutral wires), Vinyl tape (if using Jacketed Cable with Drain Wires), Conductive copper tape (if using Jacketed Copper Tape Shield Cable), Silicone lubricant (for test point cap)

  1. Perform Initial Checks and De-energize Apparatus

    Before starting, inspect all package contents for completeness and damage. Verify compatibility of all components with the cable and mating products. Read the entire installation instructions. DANGER: Ensure all apparatus is de-energized during installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products in the work area. This product must be installed only by competent personnel trained in high voltage safety practices.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Prepare the cable end according to its type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) by removing the outer jacket, copper tape shield (if applicable), and insulation shield to the specified dimensions. Cut the cable squarely at the bushing centerline. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first. Remove the shield and insulation 2-1/8" (55mm) from the cable end, taking care not to nick the conductor. Remove the insulation shield 6-7/8" (175mm) from the cable end and bevel the insulation end 1/8" (5mm) maximum. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Install the Compression Lug

    Wire brush bare aluminum conductors immediately before installation. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.

  4. Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Connect Grounding and Neutral Wires

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect Elbow to Bushing (De-energized)

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2" (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow connector and bushing interface. Do not operate by hand.

  7. Perform Voltage Test (262LR with Test Point)

    If the 262LR connector is equipped with an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.