ABB Installation Products 162LR-D5270 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable…
UPC: 075114188128
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15 kV voltage rating for medium-voltage applications
- 200 Amp current rating for reliable power distribution
- Accommodates cable insulation diameters from 0.890" to 1.220"
- Designed for 4/0 AWG stranded wire compatibility
- Bi-metal compression lug for durable, low-resistance connections
- Loadbreak elbow design enables safe connection/disconnection under load
- Test point for system diagnostics and quick verification
- Part of ABB 162LR series for medium-voltage infrastructure
Specifications
Amperage Rating | 200 A |
Application | 15kV, 200 Amp |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Push-In |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.0300 L |
Package Weight (Metric) | 0.9210 kg |

162LR-C5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
262LR-C2220
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug.
262LR-B5240
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-C5210-S
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.
162LR-D5270-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
262LR-B5240-SG3
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.Frequently Asked Questions
What certifications does the enhanced elbow hold?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What are the voltage ratings for this elbow?
The enhanced Elastimold 200 amp loadbreak elbow is available in 15 kV and 25 kV series.
Does the product have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
Is the elbow compatible with Elastimold bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What safety features does the enhanced elbow include?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What material is the pulling eye made from?
The pulling eye is made from robust stainless steel, promoting durable hotstick control.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for easier switching operations.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
What is the purpose of the rigid probe support?
The internal rigid probe support ensures proper switching and easy probe installation.
Is the elbow compatible with Elastimold bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
How to Install 161LR and 162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR (without test point) and 162LR (with test point) Loadbreak Elbow Connectors on various UD cables, including cable preparation, lug installation, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Hotstick, Wire strippers, Crimping tool, Suitable voltage sensing device
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Vinyl tape, Conductive copper tape, Cold shrink tube, Insulated cap(s) or connector(s)
- Perform Initial Safety Checks and Cable Training
DANGER: De-energize all apparatus before installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products in the work area. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Train the cable to ensure adequate slack for ease of operation. Prepare the neutral wires or grounding braid wire according to your specific cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), following the specified lengths for removing outer jacket, unwrapping neutrals, and binding/folding wires. If using a cold shrink sealing kit (e.g., 200ECS, 200ECS-G1, G2, or G3), slide the cold shrink tube onto the cable loose end first, if applicable for your cable type.
- Prepare Cable End and Install Compression Lug
Remove the insulation shield and primary insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut and taking care not to nick the conductor. Thoroughly wire brush bare aluminum conductors and immediately install the compression lug onto the conductor, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 6-7/8 inches (175mm) from the end of the primary insulation. Bevel the end of the primary insulation a maximum of 1/8 inch (5mm). Thoroughly clean the primary insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s). Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable with a back-and-forth twisting motion until it is fully seated. Wipe off all excess lubricant. Align the elbow's operating eye with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. If the elbow is preordered with a ground wire, proceed to the next step. Twist all concentric neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the grounding installation.
- Connect Elbow to Bushing Plug
WARNING: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing (at this point the contacts are approximately 4 inches apart). DO NOT HOLD IN THIS POSITION BUT IMMEDIATELY PUSH THE ELBOW HOME WITH A FAST, FIRM, STRAIGHT MOTION. Use sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
- Perform Voltage Test (162LR Only)
This step applies only to 162LR connectors equipped with an integral capacitance test point. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter that is used. Remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly in line with the test point assembly. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. WARNING: Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false “no voltage” indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means. After voltage detection has been made, clean the inside surface of the cap, lubricate it with silicone lubricant supplied, and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.