Authorized ABB Distributor (Installation Products)
ABB - Installation Products 162LR-B-2230 - 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug

ABB Installation Products 162LR-B-2230 15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable…

UPC: 075114186377


Documents & Media
BrochureInstallation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-B-2230 is a 15kV, 200 Amp loadbreak elbow connector designed for reliable power distribution. This connector is engineered to accommodate cable insulation diameters ranging from .635 inches to .905 inches, ensuring compatibility with a variety of medium voltage cables. It features a copper compression lug suitable for #1 stranded wire, providing a secure and robust electrical connection. The integrated test point allows for safe and efficient testing of the circuit without de-energizing the system, enhancing operational safety and maintenance procedures. Manufactured by ABB - Installation Products, this elbow connector is built to meet the demands of electrical utilities and industrial facilities requiring dependable loadbreak connections. Its construction prioritizes secure termination and operational integrity for critical power systems. Key specifications include: * Voltage Rating: 15kV * Amperage Rating: 200 Amp * Cable Insulation Diameter: .635 inch - .905 inch * Wire Size: #1 Stranded * Connector Type: Copper Compression Lug * Features: Loadbreak, Test Point This connector is essential for applications requiring safe and efficient switching and termination of medium voltage power circuits.
  • 15kV Voltage Rating
  • 200 Amp Current Rating
  • Accommodates .635" - .905" Cable Insulation Diameter
  • Includes Test Point for Safe Circuit Testing
  • Copper Compression Lug for #1 Stranded Wire

Specifications

Amperage Rating
200 A
Application
The 162LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Housing - EPDM-Rubber
Material
Copper
Series
162LR-B
Size
0.635 inch to 0.905 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Non-Corrosive Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.

K656LR-L2230

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Copper Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Compressed/Stranded #1 or Compact/Solid 1/0 or mm2 Compact 50.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug

162LR-B-2220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B-5200

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.

162LR-B (CTN)

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.

755LRTP-K0240-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
35kv, 600 Amp, Loadbreak, Elbow, Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 1000 Compressed/Stranded

755LR-P0410

35kv, 600 Amp, Loadbreak, Elbow, Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 1000 Compressed/Stranded

Frequently Asked Questions

What is the purpose of the rigid probe support?

The internal rigid probe support ensures proper switching and easy probe installation.

Is an optional integral jacket seal available?

Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.

Does the elbow have grounding eye positions?

Yes, the enhanced design includes dual grounding eye positions.

What material is used for the pulling eye?

The loadbreak elbow features a robust stainless-steel pulling eye.

What certifications and standards does the product meet?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What are the voltage ratings for this loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV systems.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV systems, designed for easier switching operations.

Does the elbow have grounding eye positions?

Yes, the enhanced design includes dual grounding eye positions.

What certifications and standards does the product meet?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What material is used for the pulling eye?

The loadbreak elbow features a robust stainless-steel pulling eye.

How to Install the 162LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 162LR Loadbreak Elbow Connector, including cable preparation, assembly, and grounding. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire strippers, Cable cutting tool, Wire brush, Crimp tool, Hotstick

Supplies needed:

162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), UD cable (appropriate type), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector for neutral wires, Cold shrink tube (if using sealing kit), Conductive copper tape (if using specific sealing kits), Vinyl tape (if using specific cable types)

  1. De-energize Apparatus and Inspect Components

    DANGER: All apparatus must be de-energized during installation. Failure to follow this instruction will result in serious or fatal injury. Before beginning, ensure all apparatus in the work area are completely de-energized. Verify the contents of the package are complete and undamaged. Inspect all components for proper fit with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; it should turn freely without resistance. Replace any damaged components.

  2. Prepare Cable for Termination

    Train the cable to ensure adequate slack for future operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the product manual for removing the outer jacket and managing neutral or drain wires. Cut the cable squarely at the bushing centerline. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Prepare Conductor and Insulation

    Remove the cable shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush any bare aluminum conductors immediately. Remove the insulation shield 6-7/8 inches (175mm) from the cable end, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Install Compression Lug

    Install the compression lug onto the prepared conductor. Rotate the lug to spread any inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable.

  5. Assemble Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY. DO NOT SUBSTITUTE other lubricants. Maintain cleanliness. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  6. Connect Grounding Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.

  7. Connect Elbow to Bushing

    CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. WARNING: Only operate with a full insulated 'hotstick' type tool. Consult your company’s safe work practices for required tool length. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.