ABB Installation Products 262LR-C2220 25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable…
UPC: 075114191951
Contact for Pricing
Minimum Qty: 12
Multiplier: 12
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25kV voltage rating
- 200 Amp continuous current rating
- Integrated test point for safe voltage testing
- Accommodates cable insulation diameter: .805" - 1.060"
- Designed for #2 stranded copper wire with copper compression lug
Specifications
Amperage Rating | 200 A |
Application | 25 kV, 200 Amp |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Copper |
Material | Housing - EPDM-Rubber |
Series | 262LR |
Size | 0.805 inch - 1.060 inch Cable Insulation Diameter, #2 Stranded Wire Size |
Size | 9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Special Features | 28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 10.5 IN x 19.12 IN x 12.5 IN |
Package Dimensions (L x W x H) | 26.67 cm x 48.5648 cm x 31.75 cm |
Package Weight (Imperial) | 2.3100 L |
Package Weight (Metric) | 1.0480 kg |

162LR-A-2220
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
262LR-B5240
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
262LR-C5210-S
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included.
162LR-D5270-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
262LR-B5240-SG3
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What material is the pulling eye made from?
The loadbreak elbow features a robust stainless-steel pulling eye, promoting durable hotstick control.
Is an integral jacket seal available for the elbow?
Yes, the enhanced Elastimold 200 amp loadbreak elbow offers an optional integral jacket seal.
Does the loadbreak elbow have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
What standards and certifications does the product meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
Is the loadbreak elbow compatible with Elastimold bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What safety features does the enhanced loadbreak elbow include?
It includes improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow designed for 15 kV and 25 kV series, incorporating innovative design and manufacturing experience to address end users’ needs.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV series applications.
What standards and certifications does the product meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
How to Install the 262LR Loadbreak Elbow Connector
This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, designed for terminating UD cables to 25kV class loadbreak bushings. It includes cable preparation, connector assembly, and grounding procedures.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Wire brush, Crimp tool, Wire strippers, Hotstick, Vinyl tape
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral wire connector, Cold shrink tube (if applicable), Conductive copper tape (if applicable)
- Perform Initial Safety Checks and Component Verification
DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high voltage electrical safety. Inspect all package contents for completeness and damage. Verify proper fit of all components with the cable and mating products. Check probe threads by hand-threading into the compression lug; replace if resistance is encountered. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack for future operation. Depending on your specific cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the appropriate instructions for pulling extra cable for neutral wires (24-26 inches beyond bushing centerline) or removing the outer jacket (9-5/8 inches) and copper tape shield (7-1/8 inches). Cut the cable squarely at the bushing centerline. If using a cold shrink kit, slide the cold shrink tube onto the cable loose end first.
- Prepare Conductor and Insulation
Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the manufacturer's chart, rotating 180 degrees for successive crimps. Carefully wipe off excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield and bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt and inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Hand-thread the probe into the lug, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Establish Grounding Connections
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.
- Connect the Elbow to the Bushing
DANGER: Re-confirm that both the transformer and the elbow are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Remove any insulated cap from the bushing. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.