Overview
- 200 Amp, 25kV loadbreak elbow connector for medium-voltage applications
- Bi-metal compression lug compatible with AWG #3 compressed stranded or #2 solid conductors (26.67 mm²)
- Accommodates cable insulation diameters from 0.805 to 1.060 inches
- Integrated test point for safe voltage verification without de-energization
- Includes 200ECS jacket seal for superior environmental protection
- 200ECS jacket seal included for environmental protection
- Part of ABB's 262LR series for reliable medium-voltage connections
Specifications
Amperage Rating | 200 A |
Application | 200 kV, 200 Amp |
Color | Black |
Conductor Range | #3 STR/COMPR AWG , #2 SOL/COMPT AWG |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 9.03 inch (299.4 mm) X 8.20 inch (208.3 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Special Features | 28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LR-C5210
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug.
162LR-D5270-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5260
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
262LR-B5240-SG3
200 Amp, 25kV, Loadbreak Elbow with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5270-S
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
262LR-B5230
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
162LR-C5260-SG3
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01. 200ECS-G3 Jacket Seal and Grounding Kit Included.
162LR-D5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression LugFrequently Asked Questions
Is an integral jacket seal available?
Yes, the enhanced design includes an optional integral jacket seal.
What material is the pulling eye made from?
The pulling eye is made from robust stainless steel, promoting durable hotstick control.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Is this product suitable for rural infrastructure?
Yes, it has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA), authorizing its use in rural infrastructure construction.
What standards and certifications does it meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
How does the elbow reduce life cycle costs?
It is optimized for switching operations, provides lifetime ease of operation and non-stick performance with Elastimold bushings, and has an improved seal system.
What flexibility improvements does the elbow offer?
It offers additional sizes, wider cable ranges, an easy order system, and an optional integral jacket seal.
What safety features does the elbow include?
It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface, a robust stainless-steel pulling eye, and dual grounding eye positions.
What is the enhanced Elastimold product?
It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for easier switching operations.
What is the enhanced Elastimold product?
It is an enhanced 200 amp loadbreak elbow for 15 kV and 25 kV series, designed for easier switching operations.
How to Install Elastimold 262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of the Elastimold 262LR Loadbreak Elbow Connector on various types of underground distribution cables. It covers cable preparation, conductor and insulation treatment, elbow assembly, grounding, and final connection to a bushing plug.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Hotstick, Wire brush, Crimp tool, Cable cut back template, Wire strippers or utility knife
Supplies needed:
Elastimold 262LR Loadbreak Elbow Connector, Lubricant (supplied with product), Underground Distribution (UD) Cable, Copper wire (No. 14 AWG / 2.5mm) or equivalent, Wire connectors (for neutral wires), Vinyl tape (if applicable), Conductive copper tape (if applicable), Cold shrink tube (if using a sealing kit)
- Prepare for Installation and Inspect Components
DANGER: Ensure all apparatus in the work area are de-energized before beginning installation or removal of parts. Do not touch or move energized products. Inspect all package contents to ensure they are complete and undamaged. Verify all components are compatible with the cable and mating products. Check the probe threads by hand-threading the probe into the compression lug; if resistance is encountered, replace the damaged component.
- Prepare the Cable
Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the documentation to prepare the neutral wires or grounding braid, remove the outer jacket, and cut the cable squarely at the bushing centerline. If using a sealing kit, slide the cold shrink tube onto the cable loose end first.
- Prepare Conductor and Insulation
Using a cable cut-back template for guidance, remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the lug's instructions. Remove 6-7/8 inches (175mm) of the insulation shield, beveling the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.
- Connect the Elbow to the Bushing Plug
DANGER: Before connecting, confirm that both the transformer and the elbow are de-energized. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. Do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.