ABB Installation Products 261LR-D5250 25/28kV, Load Break200 Amp Elbow No Sealing Kit
UPC: 075114245050
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Rated for 25/28kV and 200 Amp continuous current
- Load break elbow connector design
- No sealing kit included
- Manufactured by ABB Installation Products
- Origin: US
Specifications
Amperage Rating | 200 A |
Application | 25/28 kV, 200 Amp |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | 9.03 inch (299.4 mm) X 7.89 inch (200.4 mm) not including probe, 2.86 inch (72.6 mm) Diameter |
Special Features | 25/28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 25 to 28 kV |
Voltage Rating | 25/28 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.2300 L |
Package Weight (Metric) | 1.0120 kg |

168FLR3B0250
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
261LR-D5240
25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-D5230
25/28kV, 200 Amp, Loadbreak Elbow Connector, .890 inch - 1.220 Inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-C5270
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded or 250 kcmil Solid Wire Size, Bi-Metal Compression Lug.
261LR-C5240
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug.
261LR-C5250
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded or 3/0 Solid Wire Size, Bi-Metal Compression Lug.
261LR-C5240-CEPA-H
25/28kV, 200 Amp, Loadbreak Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug. CEPA-H
162LR-C5220
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Stranded Wire Size, Bi-Metal Compression LugFrequently Asked Questions
Is the product ANSI certified?
Yes, the product holds ANSI certification.
Is the product IEEE 386 compliant?
Yes, the enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant.
What is the operational benefit with Elastimold bushings?
When used with Elastimold bushings, it offers lifetime ease of operation and a non-stick interface.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Does the product have RUS acceptance?
Yes, it has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction.
What is the product's current and voltage rating?
The product is a 200 amp loadbreak elbow available for 15 kV and 25 kV systems.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Does the product have RUS acceptance?
Yes, it has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction.
What is the product's current and voltage rating?
The product is a 200 amp loadbreak elbow available for 15 kV and 25 kV systems.
What is the operational benefit with Elastimold bushings?
When used with Elastimold bushings, it offers lifetime ease of operation and a non-stick interface.
How to Install Elastimold 261LR/262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and initial connection of Elastimold 261LR and 262LR Loadbreak Elbow Connectors to various UD cables and mating bushings. Ensure all safety precautions are followed.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Insulated Hotstick Tool, Wire brush, Crimp tool, Wire strippers, Vinyl tape
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied), Copper wire (No. 14 AWG / 2.5mm), Appropriate connector for neutral wires, Cold shrink tube (if required), Conductive copper tape (if required)
- Perform Initial Safety Checks and Inspect Components
DANGER: All apparatus must be de-energized during installation. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow instructions will result in damage to the product and serious or fatal injury. Before starting, ensure all apparatus is de-energized. Inspect all components (Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant) for completeness, damage, proper fit, and compatibility with cable and mating products. Check probe threads by hand-threading into the compression lug; replace if resistance is encountered. Have all required tools at hand and maintain cleanliness throughout the procedure.
- Prepare the Cable for Termination
Based on your specific cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the detailed instructions in the documentation (STEP 1) to train the cable, provide adequate slack, prepare neutral or drain wires, and cut the cable squarely at the bushing centerline. If using a cold shrink sealing kit (e.g., 200ECS, 200ECS-G1, 200ECS-G2), slide the cold shrink tube onto the cable loose end first at this stage.
- Prepare Cable End and Install Compression Lug
Remove the cable shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the compression lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the lug and cable. Remove the insulation shield as shown in the cable cut back template (6-7/8 inches or 175mm from the end of the jacket/outer shield) and bevel the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product. Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Ground the Elbow and Connect Neutrals
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. If the elbow is preordered with a ground wire, proceed to the neutral connection. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the instructions supplied with that kit to complete the grounding and neutral connection.
- Connect the Elbow to the Bushing
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant; lubricate only if known to be de-energized. Remove the insulated cap from the bushing by attaching an insulated hotstick tool to the insulated cap pulling eye and following its instructions. Securely fasten the hotstick to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing. DO NOT HOLD IN THIS POSITION, but immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND; use a full insulated hotstick type live-line tool for all operations.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.