ABB Installation Products 252LR-C5220 25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable…
UPC: 075114321419
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 25 kV phase-to-phase voltage rating, 200 Amp continuous current
- Deadbreak design allows connection/disconnection under load
- Integrated capacitive test point for safe voltage verification
- Bi-metal lug compatible with #2 stranded/compressed and #1 solid/compact conductors
- Cable insulation diameter range: 0.805-1.060 inches
- Includes compression lug, probe, probe wrench, bail assembly, lubricant, and installation kit
Specifications
Amperage Rating | 200 A |
Application | 15/25kV, 200 Amp Deadbreak Connection |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter - .805-1.060 inch |
Special Features | Equipped with an Internal Voltage Test Point. Has Provisions for De-Energized Operation using Standard Hotstick Tools |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 15 to 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
252LRJS-C5240
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
376LR-J2240
35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.
252LR-B5220
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .635-.905 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
756LR-Q0410-SG3
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.910-2.120 inches, Aluminum Lug, Conductor Size 1000 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
756LR-L0280-SG3
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 250 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
756LR-M0330-SG3
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.370-1.630 inches, Aluminum Lug, Conductor Size 500 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
262LR-A5220
25kV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter .575-.740 inches, Bi-Medal Lug, Conductor Size #2 AWG Stranded Compressed or #1 AWG Compact/Solid. No Sealing Kit.Frequently Asked Questions
What are the operating voltage limits for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 15.2kV and the maximum phase-to-phase is 26.3kV.
Is a sealing and grounding kit recommended for this product?
Yes, for safety purposes, a sealing and grounding kit with the deadbreak elbow is highly recommended.
What are the voltage and current ratings for this connector?
The connector is rated for 15/25kV voltage class and has a continuous current rating of 200 Amps.
What industry standard does the 252LR connector meet?
The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.
What are the operating voltage limits for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
What are the voltage and current ratings for this connector?
The connector is rated for 15/25kV voltage class and has a continuous current rating of 200 Amps.
What are the operating voltage limits for the 15kV class?
For the 15kV class, the maximum phase-to-ground operating voltage is 8.3kV and the maximum phase-to-phase is 14.4kV.
What are the operating voltage limits for the 25kV class?
For the 25kV class, the maximum phase-to-ground operating voltage is 15.2kV and the maximum phase-to-phase is 26.3kV.
What industry standard does the 252LR connector meet?
The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.
Is a sealing and grounding kit recommended for this product?
Yes, for safety purposes, a sealing and grounding kit with the deadbreak elbow is highly recommended.
How to Install 252LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing the 252LR Deadbreak Elbow Connector, designed to terminate UD cable with concentric neutral and semi-con shielding, connecting to 25kV class deadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Wrench, Wire brush, Crimp tool (as per compression lug instructions), Fully insulated hot stick, Wire strippers, Suitable voltage sensing device
Supplies needed:
252LR Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied with connector), Hold-down Bail, No. 14 AWG / 2.5mm copper wire, Appropriate ground connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)
- Perform Initial Inspection and Safety Checks
DANGER: All apparatus must be de-energized during installation or removal of parts. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility. Check the contents of the package to ensure they are complete and undamaged. Verify the elbow housing cable entrance size and compression lug size for proper fit with the cable. Check threads by threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. If a test point cap is not installed, lubricate the cap and test point, then install the cap.
- Train and Cut the Cable
Train the UD cable as shown in the documentation to ease operation and ensure proper alignment. Cut any excess cable squarely at the center line of the bushing, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer.
- Prepare the Cable End
Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable. Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Remove the semi-con shield as shown in the cable cut-back template. Bevel the insulation end a maximum of 1/8 inch (3.2mm). Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish without cutting or nicking the insulation.
- Install the Compression Lug
Wire brush the bare aluminum conductors immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so that the contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for recommended crimp tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Assemble the Elbow Housing
Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess silicone lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten with the supplied wrench until the wrench bends, indicating proper torque.
- Install the Hold-Down Bail
Place the hold-down bail into the hold-down bracket. Compress the bail and insert it securely into the brackets.
- Connect Concentric Neutral to Ground
Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Bushing Plug
Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate both surfaces with the supplied lubricant ONLY if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. DANGER: DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.
- Secure Elbow with Bail
Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need to be readjusted when removing and replacing the elbow.
- Perform Voltage Test (Post-Installation)
WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Remove the test point cap with a hotstick, peeling it off at an angle. Test with a suitable sensing device, made for use with separable connectors with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.