ABB - Installation Products 261LR-C5270-SG3 - 25/28kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .805-1.060 inches, Bi-Medal Lug, Conductor Size 4/0 AWG Stranded Compressed or 250 kcmils Compact/Solid. With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

ABB Installation Products 261LR-C5270-SG3 25/28kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter…

UPC: 075114321969


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 261LR-C5270-SG3 is a 25/28kV, 200 Amp Loadbreak Elbow designed for medium-voltage cable terminations in electrical distribution systems. This model excludes a test point, simplifying installation for applications where it is not required. It features a Bi-Metal lug, accommodating conductor sizes from 4/0 AWG Stranded Compressed to 250 kcmils Compact/Solid, with cable insulation diameters ranging from 0.805 to 1.060 inches. The included SG3 Sealing Kit utilizes cold shrinkable technology, providing a robust, watertight seal with copper braid for conductivity and a constant force spring to maintain integrity across temperature fluctuations. The elbow connector housing is fully shielded and submersible, constructed from peroxide-cured EPDM materials for durability. It meets ANSI/IEEE Standard 386, with a maximum phase-to-ground operating voltage of 16.2kV, phase-to-phase voltage of 28kV, and a 140kV BIL impulse withstand rating. The 200 Amp continuous and loadbreak rating supports 10kA symmetrical momentary and fault close operations. Designed for hotstick operation, it provides a visible disconnect and standard interface for connecting to 28kV, 200 Amp bushing inserts, junctions, and accessories. Ideal for underground distribution systems, pad-mounted transformers, and switchgear applications where reliable, loadbreak-capable terminations are required.
  • 25/28kV voltage rating with 200 Amp continuous/loadbreak current capacity
  • Bi-Metal lug supports 4/0 AWG Stranded Compressed to 250 kcmils Compact/Solid conductors
  • Cable insulation diameter range: 0.805–1.060 inches
  • Includes SG3 Cold Shrink Sealing Kit with copper braid and constant force spring
  • Meets ANSI/IEEE Standard 386 with 140kV BIL impulse withstand rating

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 25/28kV class, 200 Amp Distribution Apparatus
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter .805-1.060 inches
Special Features
25/28kV, 200 Amp Loadbreak Elbow. Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
25 to 28 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.6300 L
Package Weight (Metric)
1.1930 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

756LR-P0380-SG3

15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.725-1.935 inches, Aluminum Lug, Conductor Size 750 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .805-1.060 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-C5220

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .805-1.060 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LRJS-C5240

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, with Jacket Seal, Cable Insulation Diameter - .805-1.060 inch. Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed or 2/0 Compact/Solid. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.

376LR-J2240

35KV, 200 Amp, Loadbreak Elbow, with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0.
25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .635-.905 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.

252LR-B5220

25 kV, 200 Amp, Deadbreak, Elbow Connector with Test Point, No Sealing Kit, Cable Insulation Diameter - .635-.905 inch, Bi-Metal Lug, Conductor Size #2 Stranded/Compressed or #1 Solid/Compact. Includes Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Bail Assembly, Tube of Lubricant, Installation Instructions, Crimp Chart and V.D. Cap-Peroxide.
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.910-2.120 inches, Aluminum Lug, Conductor Size 1000 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

756LR-Q0410-SG3

15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.910-2.120 inches, Aluminum Lug, Conductor Size 1000 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.
15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 250 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

756LR-L0280-SG3

15/25/35kV, 600 Amp, Deadbreak Elbow, with Test Point (includes Plug, Cap, Stud, Lug and Cable Adapter), Cable Insulation Diameter 1.180-1.465 inches, Aluminum Lug, Conductor Size 250 kcmils Stranded Compressed, With SG3 Sealing Kit - Cold Shrinkable Seal with Copper Braid and Contant Force Spring.

Frequently Asked Questions

What is the voltage rating of this loadbreak elbow?

The ABB 261LR-C5270-SG3 loadbreak elbow is rated for 25/28kV.

What conductor sizes can this elbow accommodate?

This elbow accepts 4/0 AWG Stranded Compressed or 250 kcmils Compact/Solid conductors.

What is the specified cable insulation diameter range?

The cable insulation diameter range for this elbow is .805 to 1.060 inches.

Does this loadbreak elbow include a test point?

No, this specific model, 261LR-C5270-SG3, is designed without a test point.

What type of sealing kit is included?

The included SG3 Sealing Kit is cold shrinkable and features a copper braid and constant force spring.

How to Install the 262LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 262LR Loadbreak Elbow Connector, including cable preparation, elbow assembly, and grounding.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick tool

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm), Appropriate neutral connector

  1. Perform Initial Safety Checks and Component Inspection

    Before starting, ensure all apparatus is de-energized. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Read all instructions thoroughly and have required tools ready. Do not touch or move energized products in the work area.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the manual for preparing neutral wires, removing the outer jacket, and cutting the cable squarely at the bushing centerline. Ensure proper dimensions are met for shield and jacket removal.

  3. Prepare Cable End and Install Compression Lug

    Remove the insulation shield and insulation 2-1/8” (55mm) squarely from the cable end, taking care not to nick the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread inhibitor, ensuring the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor.

  4. Final Cable Insulation Preparation

    Remove the insulation shield 6-7/8” (175mm) from the cable end. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor, ensuring a straight, smooth, and squared surface.

  5. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  6. Ground the Elbow Connector

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow and twist it tightly, being careful not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation.

  7. Connect the Elbow to the Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2” (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.