ABB - Installation Products 252LR-A5220 - 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
More images

ABB Installation Products 252LR-A5220 15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 075114345767


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 252LR-A5220 Deadbreak Elbow Connector is a high-voltage cable termination solution designed for 15/25 kV power distribution systems, rated for 200 Amps continuous current. This connector features a fully shielded, dead-front molded rubber housing with a bi-metal lug for secure aluminum or copper conductor terminations. The integrated test point allows safe voltage verification without de-energizing circuits, enhancing operational safety and maintenance efficiency. Key specifications include a cable insulation diameter range of 0.575–0.740 inches (14.61–18.80 mm), accommodating conductor sizes from #2 Stranded/Compressed to #1 Solid/Compact. The compact design measures 5.454 x 7.531 inches with a 2.097-inch diameter, making it suitable for both underground and overhead applications. The kit includes all necessary components for installation: elbow connector housing, bi-metal lug, test point probe, probe wrench, bail assembly, V.D. Cap-Peroxide, lubricant tube, crimp chart, and detailed instructions. The peroxide-cured EPDM construction ensures long-term reliability and resistance to environmental stressors. This connector meets ANSI/IEEE Standard 386 requirements for deadbreak operations, providing a dependable solution for utility and industrial power systems requiring secure, submersible cable connections.
  • 15/25 kV voltage class, 200 Amp continuous rating
  • Bi-metal lug for aluminum or copper conductors (#2 Stranded/Compressed to #1 Solid/Compact)
  • Cable insulation diameter range: 0.575–0.740 inches (14.61–18.80 mm)
  • Integrated test point for safe voltage verification without de-energizing circuits
  • Kit includes all installation components: housing, lug, probe, wrench, bail assembly, lubricant, and instructions

Specifications

Amperage Rating
200 A
Application
15/25kV, 200 Amp Deadbreak Connector
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection
Compression
Connection Type
Deadbreak Elbow Connector
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
7.531 in
Length
191.2874 mm
Material
Housing - EPDM-Rubber
Material
Polyethylene
Mounting Type
Bail Assembly
Series
252LR
Size
5.454 x 7.531 inches, 2.097 inch diameter
Special Features
Fully Shielded, fully Submersible Molded Rubber Housing. Provision for Hot Stick Operation. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Width
5.454 in
Width
138.5316 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80 mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5210

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80 mm), Bi-Metal Lug, Conductor Size 210 - #3 Stranded/Compressed, #2 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5230

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 230 - #1 Stranded/Compressed, 1/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 4/0 stranded/compressed or 250 Compact/solid. With Cold Shrinkable Jacket Seal

K656LR-H0270-S

600 Amp, 15/25kv, 600 Series Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation .850 to 1.050 inch. Aluminum Lug, Conductor Size 4/0 stranded/compressed or 250 Compact/solid. With Cold Shrinkable Jacket Seal
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed, 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-A5240

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.575-0.740 inches (14.61-18.80mm), Bi-Metal Lug, Conductor Size 240 - 1/0 Stranded/Compressed, 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-B5250

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 250 - 2/0 Stranded/Compressed, 3/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Cold-Shrinkable Jacket Seal.

252LR-B5220-S

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 220 - #2 Stranded/Compressed, #1 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter. Cold-Shrinkable Jacket Seal.
15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

252LR-B5260

15/25kV, 200 Amp, Deadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635-0.905 inches (16.13-22.99mm), Bi-Metal Lug, Conductor Size 260 - 3/0 Stranded/Compressed, 4/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Bail Assembly, V.D. Cap-Peroxide, Tube of Lubricant, Crimp Chart and Installations Instructions. 5.454 x 7.531 inches, 2.097 inch diameter.

Frequently Asked Questions

What is the product's voltage rating?

The product is rated for 15/25kV voltage classes. For 15kV, max phase-to-ground is 8.3kV; for 25kV, it's 15.2kV.

When is a cable adapter required for installation?

A cable adapter (160CA-XX) is required for cables that have an outside diameter less than 0.565 inches.

What sealing kit is used for jacketed concentric neutral cables?

For jacketed concentric neutral cables, use the 200ECS sealing kit or add suffix "-S" to the part number for cables with nominal O.D. within 0.80 in. - 1.50 in.

Is a sealing and grounding kit recommended?

Yes, a sealing and grounding kit is highly recommended for safety purposes with the deadbreak elbow.

Which elbow housing is compatible with the 160CA adapter?

The 160CA adapter can only be used in a 165/166LR elbow size housing.

What is the purpose of the 160CA cable adapter?

The 160CA Elbow Cable Size Adapter is designed for small cables with insulation outside diameters between 0.495 in. to 0.685 in.

What conductors are compatible with the copper lug?

The copper compression lug is suitable for all copper conductors only.

What conductors are compatible with the bi-metal lug?

The bi-metal compression lug with a universal aluminum barrel is suitable for both copper and aluminum conductors.

What is included in the connector kit?

The kit includes the elbow connector housing, a bi-metal compression lug, probe, probe wrench, bail assembly, lubricant, installation instructions, crimp chart, and V.D Cap-Peroxide.

Can the connector be operated with a hot stick?

Yes, the connector includes provisions for de-energized operation using standard hotstick tools.

How to Install Elastimold 252LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for installing the Elastimold 252LR Deadbreak Elbow Connector, designed to terminate UD cable and connect to 25kV class deadbreak bushings or accessory devices.

Estimated time: 1h

Tools needed:

Wrench, Wire brush, Crimp tool, Fully insulated hot stick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant, Hold-down Bail, UD cable, No. 14 AWG Copper Wire, Grounding connector

  1. Ensure De-energized State and Personnel Competence

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Perform Pre-Installation Checks

    Verify all package contents are complete and undamaged. Confirm the elbow housing cable entrance size and compression lug size are appropriate for the cable. Thread the probe into the compression lug by hand to check for resistance; if resistance is encountered, inspect for damage and replace components as needed. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  3. Train the Cable

    Train the UD cable as shown in the diagram to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut any excess cable squarely at the center line of the bushing.

  4. Prepare Concentric Neutral Wires

    Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the end of the cable.

  5. Remove Shield and Insulation

    Remove the shield and insulation from the cable end, cutting squarely. Take extreme care not to nick the conductor or insulation. Bevel the insulation end a maximum of 1/8 inch (3.2mm).

  6. Install Compression Lug

    Wire brush the bare aluminum conductors immediately. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  7. Remove Semi-Con Shield and Clean Insulation

    Remove the semi-con shield as shown in the cable cut back template. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared surface without nicks.

  8. Lubricate Cable and Elbow Housing

    Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY. DO NOT SUBSTITUTE other lubricants, as they may be harmful to this product or its mating product(s). Keep the insulation free of dirt and grime.

  9. Slide Elbow Connector onto Cable

    Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess silicone lubricant.

  10. Align and Thread Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten with the supplied wrench until the wrench bends, indicating proper torque.

  11. Assemble Hold-Down Bail

    Place the hold-down bail into the hold-down bracket. Compress the bail and insert it into the brackets.

  12. Connect Grounding Wire to Elbow

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist it tightly, ensuring not to damage the eye.

  13. Connect Neutral Wires to Ground

    Twist all concentric neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  14. Clean and Lubricate Mating Parts for Connection

    Clean the receptacle portion of the elbow connector and the mating bushing. Lubricate these surfaces with the supplied lubricant ONLY IF the transformer and elbow are known to be DE-ENERGIZED. WARNING: Do not lubricate if energized.

  15. Connect Elbow to Bushing

    Use a fully insulated hot stick to place the elbow onto the bushing. DO NOT OPERATE BY HAND. DO NOT SEPARATE IF ENERGIZED.

  16. Secure Elbow with Hold-Down Bail

    Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt clockwise. Adjust the nut on the eyebolt to allow it to seat securely in the locator, acting as a stop to prevent excessive force on the elbow. Once set, the nut will not require readjustment for future removal/replacement.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.