ABB - Installation Products 167RLR-F-5220-S - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

ABB Installation Products 167RLR-F-5220-S 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…

UPC: 783786386826


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 167RLR-F-5220-S is a 200 Amp, 15kV loadbreak elbow connector designed for reliable electrical connections. This replacement elbow features a bi-metal compression lug, suitable for conductor sizes ranging from AWG compressed stranded #2/solid #1 (33.62 mm²). It accommodates cable insulation diameters between 0.640 inches and 0.820 inches. The connector includes a 200ECS jacket seal for enhanced protection and a long bi-metal contact (00400X) for extended reach and secure termination. Notably, this repair elbow offers an extended length contact and housing, providing a net gain of 8-7/8 inches in overall length, which can be critical for specific installation requirements. This unit does not include a test point. Manufactured by ABB - Installation Products.
  • 200 Amp, 15kV Loadbreak Elbow Connector
  • Bi-Metal Compression Lug for AWG #2/#1 (33.62 mm²)
  • Cable Insulation Diameter Range: 0.640" - 0.820"
  • Includes 200ECS Jacket Seal and 00400X Long Bi-Metal Contact
  • Extended length for installation flexibility (8-7/8" net gain)

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.640 inch to 0.820 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Replacement Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.0000 L
Package Weight (Metric)
0.9070 kg
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.

K655LR-F5220

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.

755LR-N0400

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

167RLR-G-5220

200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

376LR-J5250-S

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

168ELR-88110-5260

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168RLR-H5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

755LR-N0330-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

755LR-J0310

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

Frequently Asked Questions

What is the current rating of the elbow connectors?

The elbow connectors are rated for 200 A loadbreak applications.

What voltage classes do these connectors support?

The ABB Elastimold loadbreak repair and replacement elbows are available for 15 kV and 25 kV voltage classes.

How much length does the repair elbow add?

The repair elbow features an extended housing and compression lug length that is 3 1/4 inches longer than the standard elbow.

How much length does the replacement elbow add?

The replacement elbow extends its housing and compression lug length to 8 7/8 inches over the standard elbow.

What material are the elbows constructed from?

The elbows are constructed from specially formulated, non-rigid ethylene propylene diene monomer (EPDM) rubber.

Are these elbow connectors certified?

Yes, these connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

Where are Elastimold elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, and tested in Albuquerque, NM, USA.

What is the test point cap catalog number?

The test point cap catalog number for elbows with a test point is 156-7.

What is the cable insulation diameter range for 167RLR-F?

For the 167RLR-F, the cable insulation diameter range is 0.640 inches minimum to 0.820 inches maximum.

What is the primary use of this product?

It is used to transition from live-front to dead-front equipment without splicing or pulling new cable, especially when replacing switchgear and transformers.

How to Install Elastimold 167RLR/168RLR Loadbreak Replacement Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial connection of Elastimold 167RLR (without Test Point) and 168RLR (with Test Point) Loadbreak Replacement Elbow Connectors, converting a livefront termination to deadfront for UD cable.

Estimated time: 1h 30m

Tools needed:

Hotstick, Probe Wrench, Wire brush, Wire strippers, Crimping tool, Suitable sensing device (for 168RLR voltage test)

Supplies needed:

Replacement Elbow Connector Housing (167RLR or 168RLR), Compression Lug, Probe, Lubricant (supplied by Elastimold), Hose Clamp, Copper wire (No. 14 AWG / 2.5mm), Appropriate ground connector, HV insulated cap(s) or connector(s)

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. Inspect all package contents to ensure they are complete and undamaged. Check all components for proper fit with the cable and/or mating products. Thread the probe into the compression lug to check for resistance; if resistance is encountered, check for damage and replace the component. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Remove Existing Livefront Terminator

    DANGER: All apparatus must be de-energized during this step. Remove the rubber cap from the terminator. Cut off the existing connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.

  3. Prepare Cable End

    Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches from the bushing centerline. Check the distance from the end of the cut cable to the insulation shield; if it measures less than 6-1/2 inches, proceed. If greater, consult an ELASTIMOLD representative. Remove 1-3/8 inches of cable insulation from the end of the cable, ensuring to cut squarely and DO NOT NICK THE CONDUCTOR.

  4. Install Compression Lug

    Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with the compression lug for recommended crimp information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Lubricate and Assemble Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Keep the insulation clean of dirt and grime. DO NOT USE EXCESS GREASE and do not introduce any grease into the gap between the lug and the insulation. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease.

  6. Install and Tighten Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  7. Connect Concentric Neutral

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. Add the hose clamp as shown in the diagram and tighten it snugly; DO NOT OVERTIGHTEN.

  8. Lubricate and Connect Elbow to Bushing

    LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until the first slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Apply sufficient force to ensure the internal lock engages. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.