ABB Installation Products 167RLR-G-5220 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable…
UPC: 783786366682
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp, 15kV loadbreak elbow connector
- Cable insulation diameter range: 0.760" to 0.950"
- Bi-metal compression lug for #2/AWG compressed stranded or #1/AWG solid conductors (33.62 mm²)
- Extended length design adds 8-7/8 inches for improved installation flexibility
- Includes pre-installed 00400X bi-metal contact for reduced assembly time
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Size | Cable Insulation Diameter 0.760 inch to 0.950 inch |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended length housing and compression lug plus 10-1/2 inch (266.7mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Replacement Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

162LR-B-5220
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug
376LR-J5250-S
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.
168ELR-88110-5260
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
168RLR-H5240
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
755LR-N0330-S
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
755LR-J0310
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
376LR-H5270
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
167ELR-7495-5240-S
200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.Frequently Asked Questions
What type of contact is included with the 167RLR?
The 167RLR replacement elbow includes a long bi-metal contact, specifically part number 00400X.
Where are Elastimold 200 A elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.
Are these Elastimold elbows certified?
Yes, these elbow connectors are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.
What cable insulation diameter does the 'G' symbol support?
For the 167RLR, the 'G' symbol indicates compatibility with cable insulation diameters ranging from 0.760 in to 0.950 in.
How much length does the 167RLR elbow add?
The 167RLR replacement elbow provides a net gain of 8 7/8 inches in length due to its extended-length contact and elbow housing.
What is the current rating of these elbows?
These Elastimold elbow connectors are rated for 200 A loadbreak applications.
What is the voltage class for the 167RLR?
The 167RLR replacement elbow connector is designed for a 15 kV voltage class.
What is the purpose of this product?
The Elastimold 200 A loadbreak repair and replacement elbow connectors help transition from live-front to dead-front equipment without splicing or pulling new cable. They address varying bushing heights and insufficient cable length.
Where are Elastimold 200 A elbows manufactured?
Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.
What is the purpose of this product?
The Elastimold 200 A loadbreak repair and replacement elbow connectors help transition from live-front to dead-front equipment without splicing or pulling new cable. They address varying bushing heights and insufficient cable length.
How to Install 167RLR/168RLR Loadbreak Replacement Elbow Connectors
This guide provides step-by-step instructions for installing the 167RLR and 168RLR Loadbreak Replacement Elbow Connectors, converting livefront terminations to deadfront for UD cable. It covers cable preparation, lug installation, elbow assembly, and grounding.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimping tool, Wire strippers, Hotstick
Supplies needed:
Replacement Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Hose Clamp, No. 14 AWG / 2.5mm Copper Wire, Grounding connector
- Safety First: De-energize Apparatus
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any part(s). Failure to do so will result in serious or fatal injury. Do not touch or move energized products.
- Remove Existing Livefront Termination
Remove the rubber cap from the existing terminator. Cut off the connector at the top of the terminator. Disconnect the ground lead from the base of the terminator. Finally, remove the terminator housing from the cable.
- Prepare the Cable
Train the cable to be straight and in-line with the bushing centerline. Measure and cut the cable to 10-1/2 inches (26.7 cm) from the bushing centerline. Carefully remove 1-3/8 inches (3.5 cm) of cable insulation from the end, ensuring a square cut and avoiding nicks to the conductor. If the insulation shield measures greater than 6-1/2 inches (16.5 cm), consult an ELASTIMOLD representative.
- Install Compression Lug
Wire brush the bare aluminum conductor immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.
- Assemble Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.
- Connect Concentric Neutral
Insert one end of a separate No. 14 AWG (2.5mm) copper wire through the grounding eye on the elbow and twist it tight, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation. Add the supplied hose clamp as shown in the diagram, tightening it snugly but without overtightening.
- Connect Elbow to Bushing Plug (Initial Connection)
Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are confirmed to be de-energized. Securely fasten a hotstick to the loadbreak connector pulling eye. Align the elbow connector receptacle area over the bushing plug, inserting the elbow male contact into the bushing until a slight resistance is felt. Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow and bushing interface. Do not operate by hand.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.