ABB - Installation Products 376LR-J5250-S - 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS Jacket Seal Included.

ABB Installation Products 376LR-J5250-S 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 783786383665


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 200 Amp, 35kV Loadbreak Elbow Connector (SKU: 376LR-J5250-S) supports compressed stranded 2/0 AWG or solid 3/0 AWG conductors (67.43 mm²) with insulation diameters 0.980–1.180 inch. Features bi-metal compression lug for thermal cycling durability, integrated test point for safe voltage verification, and 200ECS jacket seal for moisture/dust protection. Meets 35kV class system requirements for loadbreak switching applications with frequent connections/disconnections. Complies with industry standards for compatibility with ABB and third-party switchgear, transformers, and terminations. Compact design simplifies confined-space installation, reducing labor time and installation errors. Suitable for utility substations, renewable energy interconnections, and industrial facilities requiring reliable, maintenance-free medium-voltage connections.
  • Rated 200 Amps, 35kV for medium-voltage applications
  • Supports compressed stranded 2/0 AWG or solid 3/0 AWG conductors (67.43 mm²)
  • Cable insulation diameter range: 0.980 inch to 1.180 inch
  • Integrated test point for safe voltage verification
  • Includes 200ECS jacket seal for environmental protection

Specifications

Amperage Rating
200 A
Application
35 kv, 200 Amp
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Push-In
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
35kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Non-Corrosive Capacitive Voltage Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

376LR-K-5250

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

168ELR-88110-5260

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168RLR-H5240

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.

755LR-N0330-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

755LR-J0310

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-H5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.

167ELR-7495-5240-S

200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. Bi-Metal Compression Lug.

168ELR-7495-5230

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. Bi-Metal Compression Lug.

Frequently Asked Questions

What is the voltage rating of the 376LR elbow connector?

The 376LR is rated for 35kV voltage class, with a maximum phase-to-ground operating voltage of 21.1kV and phase-to-phase of 36.6kV.

Can the 376LR be operated with hot stick tools?

Yes, the 376LR includes provisions for energized operation using standard hot stick tools, allowing loadmaking/loadbreak operation and a visible disconnect.

What type of voltage test point does the 376LR have?

The 376LR features a non-corrosive capacitive voltage test point.

What is the impulse withstand rating of the 376LR?

The 376LR has a 150kV BIL Impulse Withstand rating, measured with a 1.2 x 50 microsecond wave.

What types of conductors are compatible with the compression lugs?

The standard bi-metal compression lug is suitable for both copper or aluminum conductors. Copper compression lugs are for copper conductors only.

What is included in the 376LR elbow connector kit?

Each kit contains an elbow connector housing, a bi-metal compression lug, a probe, a probe wrench, lubricant, installation instructions, and a crimp chart.

Is the 376LR elbow connector suitable for submersible applications?

Yes, the 376LR features a fully shielded, fully submersible molded rubber housing.

What standards does the 376LR elbow connector meet?

The 376LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.

What cable insulation diameters does the 376LR support?

The 376LR allows connection of cables with insulation diameters from .850 in (21.6mm) to 1.465 in (37.2mm).

What is the continuous and loadbreak current rating?

The 376LR has a continuous and loadbreak current rating of 200 Amp. It also has a 10kA Sym momentary and fault close rating.

How to Install the 375LR/376LR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial connection of Elastimold 375LR (without test point) and 376LR (with test point) Loadbreak Elbow Connectors to UD cable and 35kV class bushings.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick, Suitable sensing device, Wire strippers, Utility knife

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), No. 14 AWG / 2.5mm copper wire, Appropriate connector for neutral wires, Test Point Cap (for 376LR), HV insulated cap(s) or connector(s)

  1. Inspect Package Contents and Components

    Check the contents of the package to ensure all parts are complete and undamaged. Verify all components fit properly with the cable and/or mating products.

  2. Check Probe Thread Fit

    Thread the probe into the compression lug by hand. If resistance is encountered before full assembly, inspect for damage and replace any faulty components.

  3. Train Cable

    Train the cable as shown in the diagram (20 inches minimum beyond the end of the cable pad mount transformer) to ease future operation. Cut excess cable squarely at the center line of the bushing.

  4. Prepare Concentric Neutral Wires

    Unwrap and bind the concentric neutral wires 8-1/2 inches back from the end of the cable.

  5. Remove Shield and Insulation

    Remove the shield and insulation from the cable end, cutting squarely. Take extreme care not to nick the conductor during this process.

  6. Install Compression Lug

    Wire brush bare aluminum conductors immediately. Install the compression lug, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor.

  7. Remove Insulation Shield and Clean

    Remove the insulation shield as shown in the cable cut-back template (6-7/8 inches from the end of the cable). Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  8. Lubricate and Slide Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant ONLY. Do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess grease.

  9. Align Elbow and Thread Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten with the probe wrench until the wrench bends.

  10. Connect Grounding Wire to Elbow

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye.

  11. Connect Neutral Wires to Ground

    Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.

  12. Lubricate Bushing and Elbow Receptacle

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. ONLY LUBRICATE IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED.

  13. Prepare Bushing for Connection

    Remove the insulated cap from the bushing by attaching a hotstick tool to the insulated cap pulling eye and following the accessory's instructions. Ensure the area is clear of obstructions.

  14. Connect Elbow to Bushing

    Securely fasten a hotstick to the loadbreak connector pulling eye. After establishing firm footing and positive control, insert the probe tip approximately 2 inches into the bushing. Immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. Do not hold in the partially inserted position.

  15. Perform Voltage Test (376LR Only)

    For 376LR models, remove the test point cap with a hotstick, peeling it off at an angle. Use a suitable sensing device, designed for capacitive test points, to determine if the cable is energized. Do not use conventional voltage measuring equipment. Treat the elbow as energized until confirmed otherwise by other means. After testing, clean and lubricate the cap with silicone grease and replace it.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.