Authorized ABB Distributor (Installation Products)
ABB - Installation Products 755LR-J0310 - 600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 400 /Compacted Solid 450 /mmSquared Compact 240.

ABB Installation Products 755LR-J0310 600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable…

UPC: 783786399765


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products SKU 755LR-J0310 is a 600 Amp, 35kV elbow connector designed for medium-voltage cable systems. This assembly includes an insulated plug, protective cap, compression stud, aluminum compression lug, and cable adapter to ensure secure, insulated connections in industrial power distribution. The connector accommodates cable insulation diameters from 0.980 inch to 1.180 inch and supports conductor sizes including 400 AWG/kcmil (compressed stranded), 450 AWG/kcmil (compacted solid), and 240 mm² (compact). The aluminum compression lug provides reliable mechanical and electrical termination for high-current applications. This elbow connector is engineered for use in switchgear, transformers, and other medium-voltage distribution equipment where safe, insulated separable connections are required. The 35kV rating ensures compatibility with medium-voltage systems operating at or below this voltage level. The integrated design simplifies installation and maintenance while maintaining dielectric integrity in harsh industrial environments. This product is part of ABB's Installation Products line, known for reliable components in electrical infrastructure.
  • 600 Amp, 35kV rated elbow connector for medium-voltage systems
  • Includes insulated plug, protective cap, compression stud, and aluminum lug
  • Accommodates cable insulation diameters from 0.980 to 1.180 inches
  • Supports conductor sizes: 400 AWG/kcmil (compressed stranded), 450 AWG/kcmil (compacted solid), 240 mm² (compact)
  • Designed for use in switchgear, transformers, and industrial power distribution

Specifications

Amperage Rating
600 A
Application
Designed to provide Fully Shielded, Dead-Front Submersible Cable Connections to High-Voltage Apparatus
Color
Black
Conductor Range
400 kcmil , 450 kcmil
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
755LR
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Special Features
100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected Using Standard Hand Tools and Equipment in a De-energized State. Optional Accessories allow Visible External Separation, By-Pass, Isolation, Dead-Ending, Grounding, and Testing as well as Adding Taps, Surge Arrestors, and Fault Current Indicators
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
8.9000 L
Package Weight (Metric)
4.0370 kg
15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.

K465LR-H0310

15/25kV, 630 Amps, Deadbreak Elbow without Test Point. Cable Insulation Diameter 0.850-1.050 inches (21.590-26.670mm). Aluminum Compression Lug, Conductor Size 400 Stranded/Compressed or 450 Solid/Compact or 240 mm2. Includes Elbow Connector Housing, Compression Lug, Stud, Insulated Plug with Cap, Tube Lubricant, Cable Adapter, Installation Instructions and Crimp Chart. Exceeds ANSI/IEEE Standard 386 Latest Revision.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

376LR-H5270

35kV 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.

167ELR-7495-5240-S

200 Amp, 15kV, Loadbreak Repair Elbow Connector without Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. Bi-Metal Compression Lug.

168ELR-7495-5230

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. Bi-Metal Compression Lug.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

274RLR-J-5240

200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.

755LR-K0270-S

600 Amp, 35KV, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. Cold-Shrinkable Jacket Seal Included.
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

168RLR-F-5210-S

200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. 200ECS Jacket Seal Included. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.

Frequently Asked Questions

What components are included in a 755LR kit?

Each kit contains an elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.

What is the primary use of the 755LR elbow connector?

The 755LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What voltage class is the 755LR elbow rated for?

The 755LR elbow connector is rated for use through 35kV.

What conductor sizes are compatible with the 755LR?

It is compatible with aluminum and copper conductors ranging from #2 AWG to 1250 kcmil.

What insulation diameters does the 755LR support?

The 755LR supports cable insulation diameters from 0.760 inches to 2.120 inches.

What is the maximum operating voltage for the 755LR?

The maximum phase-to-ground operating voltage is 21.1kV, and maximum phase-to-phase is 36.6kV.

What is the continuous current rating of the 755LR?

The 755LR has a continuous current rating of 600 Amps.

What industry standards does the 755LR meet?

The 755LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the impulse withstand (BIL) rating?

The impulse withstand (BIL) rating for the 755LR is 150kV.

Is the 755LR elbow connector submersible?

Yes, the 755LR features a fully shielded, fully submersible molded rubber housing.

How to Install 755/775LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and connection of 755LR and 775LR Deadbreak Elbow Connectors on 35kV class systems, including cable preparation, lug crimping, and grounding procedures. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Crimping tool, Wire brush (for aluminum conductors), Hotstick, Suitable voltage sensing device (for capacitive test points), Torque wrench (for mating parts and L-Kits)

Supplies needed:

755/775LR Deadbreak Elbow Connector Kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), High voltage cable (35kV class), Grounding wire (minimum #14 AWG Copper ampacity), Suitable grounding connector, Waterproofing material (for cable jacket, recommended), Tape marker

  1. Perform Initial Checks and Ensure Safety

    DANGER: All apparatus must be de-energized during installation or removal. Do not touch or move energized products. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Check the contents of the package to ensure they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products. Read all instructions thoroughly before starting.

  2. Position Cable and Make Initial Cut

    Position the cable in its final assembled location, ensuring enough slack to allow adequate clearance for removing the elbows. If using concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product.

  3. Clean the Cable Outer Jacket

    Clean the outer jacket of the cable for a distance of 24 inches (610mm) from the cut end to ensure a clean working surface.

  4. Prepare Cable Insulation and Shield

    Follow the specific cable preparation instructions based on your cable type (e.g., UNISHIELD, Lead Sheath, Jacketed, Non-Jacketed, Flat Metallic Tape Shield, Fabric Tape Shield, Longitudinally Corrugated Shield). This involves removing the outer jacket (if applicable) and preparing the cable insulation and semi-con shield to the specified dimensions (e.g., 10-3/8 inches, 11-3/8 inches, 13-5/8 inches from the end, and flush with a tape marker).

  5. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  6. Trim Protruding Cable Insulation

    Remove any cable insulation protruding beyond the cable adapter by cutting it even with the end of the cable adapter. Be careful not to cut or nick the cable adapter or the conductor. The exposed conductor length must be between 4-3/8 inches to 4-3/4 inches (111mm-121mm); otherwise, redo the assembly.

  7. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping, ensuring it is less than 7 inches (178mm). Crimp the compression lug according to the instructions supplied with the lug. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping must be between 6-7/8 inches to 7-5/8 inches (175mm-194mm); otherwise, redo the assembly.

  8. Install the Elbow onto the Cable Adapter

    Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter until it cannot advance further. Verify that the cable adapter remains flush with the tape marker; reposition the cable adapter if necessary. Remove the tape marker.

  9. Prepare Mating Products for Connection

    WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud supplied with the elbow into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring surfaces remain clean.

  10. Connect the Elbow to the Mating Part

    Push the elbow firmly onto the mating part, carefully lining up the hole in the compression lug with the stud on the mating part until fully seated.

  11. Complete Opposite End Connection (if applicable)

    If connecting to another mating part on the opposite end of the elbow, clean and lubricate its mating surface. Insert this mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to the instructions supplied with that specific mating part.

  12. Install Insulating Plug (if used)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap on the elbow and push down hard until it snaps securely into place.

  13. Ground the Cable Shield

    Insert one end of a piece of wire, with an ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist to make a small loop without damaging the eye. Connect this wire to ground using a suitable connector. The shield of the cable must be grounded; ground it according to the instructions supplied with any grounding device used, or via an alternate method if no device is present. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  14. Perform Voltage Test (Post-Installation)

    CAUTION: When constructing 600amp L-Kits, ensure each component is tightened to the specified torque per the plug connector instructions. The ELASTIMOLD deadbreak elbow connector features an integral capacitance test point. To use it: 1. Remove the test point cap with a hotstick, peeling it off at an angle. 2. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device designed for capacitive test points to determine if the cable is energized. Contamination, moisture, dirt, or incorrect equipment can cause a false 'no voltage' indication. Treat the elbow as energized until 'no voltage' is confirmed by other means to prevent serious or fatal injury. 3. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.