Contact for Pricing
Overview
- 15kV rated, 200 Amp continuous current capacity
- Loadbreak design with integrated test point for safe voltage verification
- Bi-metal compression lug for copper-to-aluminum compatibility
- Accepts #1 stranded or 1/0 compact/solid conductors
- 0.635" to 0.905" cable insulation diameter range
Specifications
Amperage Rating | 200 A |
Application | 15 kv, 200 Amp |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Loadbreak Jacket Seal Elbow Connector with Test Point |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Compression Lug |
Series | 162LRJS |
Size | .635 inch - .905 inch Cable Insulation Diameter, Wire Size #1 Stranded or 1/0 Compact/Solid |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in cable jacket seal. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point and Jacket Seal |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Width | 8.2 in |
Width | 208.28 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.2500 L |
Package Weight (Metric) | 1.0210 kg |

655ETP-F0230-DRG
15kV 600 Series Deadbreak Elbow TAP PLUG Connector, Test and Ground Connector Kit, Test and Ground kit includes - Insulated Cap, Test and Ground reducing tap plug, 600 series Elbow housing, cable adapter and 0370 style compression lug. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. With Insulated Cap.
162LRJS-B5240
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
162LRJS-B5230A
200 Amp, 15kV, Loadbreak Elbow with Jacket Seal, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
162LRJS-C5250
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
162LRJS-C5270
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug
162LRJS-B5250
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, 2/0 Stranded Wire Size, Bi-Metal Compression Lug
261LR-B5230
25/28kV, 200 Amp, Loadbreak Elbow Connector, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Bi-Metal Compression Lug.Frequently Asked Questions
Is an integral jacket seal available for the elbow?
Yes, an optional integral jacket seal is available for the enhanced Elastimold 200 amp loadbreak elbow.
Does the elbow feature a no-stick interface?
Yes, it has a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What is the pulling eye made from and its features?
The pulling eye is made from robust stainless steel, promoting durable hotstick control. It also features dual grounding eye positions.
What standards and certifications does the elbow meet?
The product is IEEE 386 compliant and has ANSI certification. It also has Rural Utilities Service (RUS) acceptance.
Is the Elastimold loadbreak elbow accepted by RUS?
Yes, it has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction.
What are the main safety enhancements of the elbow?
The enhanced design incorporates safety performance features like improved insulation, rigid probe support, a no-stick interface, and robust pulling and grounding eyes.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for 15 kV and 25 kV applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV series, designed with over 50 years of experience to address end-user needs.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV series, designed with over 50 years of experience to address end-user needs.
Is an integral jacket seal available for the elbow?
Yes, an optional integral jacket seal is available for the enhanced Elastimold 200 amp loadbreak elbow.
How to Install 161LRJS/162LRJS Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and assembly of 161LRJS and 162LRJS Loadbreak Elbow Connectors, including cable preparation and connection to a 15kV class loadbreak bushing.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Fully insulated hotstick tool, Wire brush, Crimp tool (refer to lug packaging for specifics)
Supplies needed:
Lubricant (supplied with connector kit), Mastic strips (supplied with connector kit), Vinyl tape, No. 14 AWG / 2.5mm copper wire, Grounding connector for neutral wires
- Ensure Safety and Inspect Components
WARNING: All apparatus must be de-energized during installation. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Inspect all package contents for completeness and damage. Verify proper fit of components with the cable and mating products. Check the probe threads into the compression lug for free movement. If the 162LRJS model is used and the test point cap is not installed, lubricate the cap and test point, then install the cap.
- Train and Prepare Cable for Neutral Connection
Train the cable to ensure sufficient slack for ease of operation. Mark the centerline of the bushing with tape and pull extra cable 24-26 inches beyond the centerline. Remove the outer jacket 7 3/4 to 8 inches back from the centerline. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline. Connect the neutral wires to the tank ground with a jumper or grounding braid, ensuring extra length to facilitate hotstick operation.
- Prepare Cable Insulation and Install Compression Lug
Wrap one mastic strip, stretching slightly, around the cable jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them into the mastic. Wrap a second mastic strip completely around the outer jacket, overlapping the imbedded neutral wires. Use a third mastic strip if needed to build up the outer diameter in the area of the first mastic location, then cover all mastic with vinyl tape. Remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart packaged with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the template and bevel the insulation end 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.
- Assemble Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the lubricant supplied; DO NOT SUBSTITUTE. Keep insulation clean of dirt and grime. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Connect Concentric Neutral Wires
Pull the hood over the concentric neutral seal area on the cable by pulling the tabs and/or rolling the seal down. Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Connect Elbow to Mating Bushing
Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. WARNING: Lubricate ONLY IF the transformer and elbow are known to be de-energized. Securely fasten a fully insulated hotstick tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches (50mm) into the bushing. Immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.