ABB - Installation Products 161LRJS-C5260 - 15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
ABB - Installation Products

161LRJS-C5260

UPC: 075114185523


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 161LRJS-C5260 is a 15kV, 200 Amp loadbreak jacket seal elbow connector designed for reliable power distribution applications. This connector features a bi-metal compression lug, ensuring robust and durable electrical connections. It is engineered to accommodate cable insulation diameters ranging from 0.805 inches to 1.060 inches, and is suitable for 3/0 stranded wire sizes. The jacket seal design provides essential protection against environmental ingress, maintaining connection integrity in challenging conditions. This ABB Installation Products component is crucial for safe and efficient termination of medium-voltage power cables. Its specifications are tailored for utility, industrial, and commercial power systems where dependable loadbreak capabilities are paramount. Key Specifications: * **Voltage Rating:** 15kV * **Current Rating:** 200 A * **Cable Insulation Diameter Range:** 0.805" - 1.060" * **Wire Size:** 3/0 AWG Stranded * **Lug Material:** Bi-Metal Compression * **Connection Type:** Loadbreak Jacket Seal Elbow Connector * **Manufacturer:** ABB - Installation Products * **SKU:** 161LRJS-C5260 This connector facilitates secure and efficient loadbreak operations, essential for switching and sectionalizing in medium-voltage networks. The bi-metal construction offers excellent conductivity and corrosion resistance, vital for long-term performance. The jacket seal design enhances safety and reliability by preventing moisture and contaminants from compromising the connection. Ideal for underground distribution systems, substations, and industrial power facilities.
  • 15kV Voltage Rating
  • 200 Amp Current Rating
  • Loadbreak Jacket Seal Elbow Connector
  • Accommodates 0.805" - 1.060" Cable Insulation Diameter
  • Designed for 3/0 AWG Stranded Wire with Bi-Metal Compression Lug

Specifications

Amperage Rating
200 A
Application
The 161LRJS is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Built in Cable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector and Jacket Seal
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

161LR-B5260

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LRTP-L0270-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

162LR-B-2250

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug

162LR-B-2230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug

162LR-B-2220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B-5200

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.

162LR-B (CTN)

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.

Frequently Asked Questions

Is the product approved for rural infrastructure?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).

What is the pulling eye made of?

The pulling eye is made of robust stainless steel, which promotes durable hotstick control.

What is the purpose of the rigid probe support?

The internal rigid probe support ensures proper switching and easy probe installation.

What certifications does the loadbreak elbow have?

The elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

Is the elbow compatible with Elastimold bushings?

Yes, it offers a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What safety features does the enhanced elbow include?

It features improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What are the voltage ratings of the elbow?

The loadbreak elbow is designed for 15 kV and 25 kV applications.

What product is being enhanced?

The Elastimold 200 amp loadbreak elbow (15 kV and 25 kV series) has received enhancements.

What is the pulling eye made of?

The pulling eye is made of robust stainless steel, which promotes durable hotstick control.

What are the voltage ratings of the elbow?

The loadbreak elbow is designed for 15 kV and 25 kV applications.

How to Install 161LRJS/162LRJS Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and assembly of 161LRJS and 162LRJS Loadbreak Elbow Connectors, including cable preparation, elbow assembly, and neutral connection.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Hotstick, Cable cut back template, Wire brush, Crimp tool, Suitable sensing device (for voltage test)

Supplies needed:

Lubricant (Do Not Substitute), Mastic strips, Vinyl tape, Separate copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Initial Safety Checks and Component Inspection

    Ensure all apparatus are de-energized before beginning installation. Inspect all parts for damage, correct rating, and compatibility with mating components. Verify package contents are complete and undamaged. Check that all components fit properly with the cable and/or mating products. Test the probe threads by threading into the compression lug; replace if resistance is encountered. Read all instructions thoroughly, gather required tools, and maintain cleanliness. If the product was supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors. If the test point cap is not installed, lubricate it and install it onto the test point.

  2. Train Cable and Prepare for Neutral Connection

    Train the cable to ensure sufficient slack for ease of operation, pulling extra cable 24 to 26 inches beyond the bushing centerline. Remove the outer jacket 7 3/4 to 8 inches back from the centerline. Unwrap the neutral wires back past the bushing centerline. Cut the excess cable squarely at the bushing centerline. Provide an extra length of concentric neutral wires or grounding braid wire to facilitate connection to the tank ground and hotstick operation.

  3. Prepare Cable Insulation and Conductors

    Wrap one strip of mastic, stretching slightly, around the outer jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them into the mastic. Wrap a second strip of mastic completely around the outer jacket, overlapping the imbedded neutral wires. Use a third strip if needed to build up the outer diameter. Cover all mastic with vinyl tape. Remove the insulation shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor.

  4. Install and Crimp Compression Lug

    Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart for recommended crimp tool information and start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  5. Final Cable Insulation Preparation

    Remove the insulation shield as indicated by the cable cut-back template. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared finish.

  6. Assemble Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute other lubricants. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the wrench until the wrench bends.

  7. Connect Concentric Neutral Wires

    Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation.

  8. Connect Elbow to Bushing (De-energized Operation)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant *only if* the transformer and elbow are known to be de-energized. Connect the elbow to the bushing using a fully insulated 'hotstick' type tool, following the operating instructions. Do not operate by hand.

  9. Perform Voltage Test (for 162LRJS with Test Point)

    If using a 162LRJS with a test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device made for capacitive test points and follow its manufacturer's directions. Treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.