ABB Installation Products 161LR-B5260 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch.…
UPC: 075114236188
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV voltage rating for medium-voltage applications
- 200 Amp current rating for high-capacity power distribution
- Bi-metal compression lug supports aluminum and copper conductors
- Cable insulation diameter range: 0.635" to 0.905"
- Loadbreak design enables safe connection/disconnection of energized circuits
- Compatible with compressed stranded conductors up to 3/0 AWG and solid conductors up to 4/0 AWG (85.01 mm²)
Specifications
Amperage Rating | 200 A |
Application | The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | 3/0 STR/COMPR AWG , 4/0 SOL/COMPT AWG |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K655YSR-H0260
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95.
161LR-D5230
15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.
161LR-C5270-SG3
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.
161LR-C5250
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
161LR-B5250
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
161LR-B5240
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
755LR-K0270
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
755LR-K0260-SG3
35kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 1.090 to 1.310 inch, Conductor Size 3/0 Compressed/Stranded or 4/0 Compact/Solid.Frequently Asked Questions
Does the product have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
Is the product compliant with industry standards?
The Elastimold loadbreak elbow is compliant with IEEE 386 standards and has ANSI certification.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What are the current and voltage ratings for this product?
The product is a 200 amp loadbreak elbow, suitable for 15 kV and 25 kV applications.
Does the product have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
Is the product compliant with industry standards?
The Elastimold loadbreak elbow is compliant with IEEE 386 standards and has ANSI certification.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
What are the current and voltage ratings for this product?
The product is a 200 amp loadbreak elbow, suitable for 15 kV and 25 kV applications.
Does the product have RUS acceptance?
Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA.
Does the elbow have a no-stick interface?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various underground distribution cables.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Wire brush, Crimp tool, Wire strippers, Hotstick, Vinyl tape
Supplies needed:
161LR/162LR Elbow Connector Housing, Compression lug, Probe, Lubricant (supplied), No. 14 AWG (2.5mm) copper grounding wire, Neutral wire connector, Cold shrink tube (if applicable), Conductive copper tape (if applicable)
- Perform Safety Checks and Initial Inspection
Ensure all apparatus in the work area are de-energized. Inspect all package contents, components, and mating parts for damage, proper fit, and compatibility. Verify the probe threads freely into the compression lug for approximately four turns before becoming snug.
- Prepare the Cable for Termination
Train the cable to ensure adequate slack for operation. Cut the cable squarely at the bushing centerline. Based on cable type, remove the outer jacket (e.g., 9-5/8" for jacketed concentric neutral) and/or copper tape shield (e.g., 7-1/8"). Unwrap and bind neutral or drain wires as required. If using a cold shrink sealing kit, slide the tube onto the cable loose end first.
- Prepare Conductor and Install Compression Lug
Remove the insulation shield and insulation 2-1/8" (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line and rotating 180 degrees for successive crimps. Carefully wipe off excess inhibitor.
- Complete Insulation Preparation
Remove the insulation shield 6-7/8" (175mm) from the cable end. Bevel the insulation end a maximum of 1/8" (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Housing
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant.
- Install and Tighten the Probe
Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding and Neutral Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation.
- Connect Elbow to Bushing Plug
CONFIRM THAT TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye and connect the elbow to the bushing with a fast, firm, straight motion. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.