ABB - Installation Products 161LRJS-C-5270 - 15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 4/0 Stranded Wire Size, Bi-Metal Compression Lug

ABB Installation Products 161LRJS-C-5270 15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable…

UPC: 075114185530


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LRJS-C-5270 is a 15kV, 200 Amp Loadbreak Jacket Seal Elbow Connector engineered for medium-voltage cable systems. This connector supports cable insulation diameters from 0.805 to 1.060 inches and accommodates 4/0 AWG stranded copper wire, making it ideal for standard industrial and utility applications. The bi-metal compression lug ensures reliable electrical continuity and mechanical strength, critical for medium-voltage distribution networks. Key features include a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured EPDM materials for long-term durability. The loadbreak design enables safe, hot-line maintenance without power interruption, reducing downtime in critical operations. The built-in jacket seal prevents moisture ingress, protecting connections from environmental contaminants and corrosion. This connector meets ANSI/IEEE Standard 386 for 15kV voltage class, with a maximum phase-to-ground operating voltage of 8.3kV and phase-to-phase voltage of 14.4kV. It provides a 95kV BIL impulse withstand, 34kV AC one-minute withstand, and 53kV DC 15-minute withstand. The 200 Amp continuous and loadbreak rating, along with 10kA symmetrical momentary and fault close capability, ensures robust performance in demanding electrical environments. Typical applications include underground distribution systems, switchgear terminations, and pad-mounted transformers where medium-voltage cable connections require both loadbreak capability and environmental sealing. The 161LRJS series is designed for connecting to and operating 15kV Class, 200 Amp distribution apparatus, providing a convenient method to connect/disconnect cable and equipment on power distribution systems. The connector includes provisions for hot stick operation and ground wire connection, enhancing safety and usability.
  • 15kV, 200 Amp continuous and loadbreak rating
  • Supports cable insulation diameters from 0.805 to 1.060 inches
  • Accommodates 4/0 AWG stranded copper wire
  • Bi-metal compression lug for reliable electrical continuity
  • Built-in jacket seal prevents moisture ingress
  • Accommodates cable insulation diameters from 0.805 to 1.060 inches

Specifications

Amperage Rating
200 A
Application
The 161LRJS is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection. Built in Cable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector and Jacket Seal
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.2000 L
Package Weight (Metric)
0.9980 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug

161LRJS-C5260

15kV 200 Amp, Loadbreak Jacket Seal Elbow Connector, .805 inch - 1.060 Inch Cable Insulation Diameter, 3/0 Stranded Wire Size, Bi-Metal Compression Lug
600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LRTP-L0270-DRG

600 Amp, 35kV, Stick-Op Connector Kit with Test Point, Insulated Cap and Reducing Tap Plug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

162LR-B-2250

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug

162LR-B-2230

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #1 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug

162LR-B-2220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size, Copper Compression Lug
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug

162LR-B-5200

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #4 Stranded Wire Size, Bi-Metal Compression Lug
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.

162LR-B (CTN)

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch.

Frequently Asked Questions

Is the Elastimold elbow compatible with other components?

The enhanced Elastimold elbow features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards and certifications does the Elastimold elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What are the voltage ratings for the Elastimold loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

Is the Elastimold elbow compatible with other components?

The enhanced Elastimold elbow features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards and certifications does the Elastimold elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

What are the voltage ratings for the Elastimold loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What are the voltage ratings for the Elastimold loadbreak elbow?

The Elastimold 200 amp loadbreak elbow is available for 15 kV and 25 kV series applications.

What standards and certifications does the Elastimold elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

Is the Elastimold elbow compatible with other components?

The enhanced Elastimold elbow features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards and certifications does the Elastimold elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.

How to Install 161LRJS/162LRJS Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation and initial connection of 161LRJS and 162LRJS Loadbreak Elbow Connectors with Jacket Seal on UD cable.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Probe wrench, Hotstick

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Sealing strips (3), Mastic strips, Vinyl tape, Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector (for neutral wires)

  1. Perform Pre-Installation Checks and Safety Precautions

    Before starting, ensure all apparatus is de-energized. Verify package contents are complete and undamaged. Check all components for proper fit with the cable and mating products. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered. Read all instructions thoroughly. Have all required tools ready and maintain cleanliness. If installing a 162LRJS, lubricate and install the test point cap if not already present. This product should only be installed by competent personnel trained in high voltage electrical safety practices.

  2. Train and Prepare the Cable

    Train the UD cable to ensure sufficient slack for future operation. Mark the bushing centerline and pull extra cable 24-26 inches beyond it. Remove the outer jacket 7 3/4 to 8 inches back from the centerline. Unwrap the neutral wires past the bushing centerline and cut the excess cable squarely at the centerline. Connect the neutral wires to the tank ground with a jumper or grounding braid, providing extra length for hotstick operation.

  3. Apply Mastic and Prepare Insulation

    Wrap one strip of mastic, stretching slightly, around the cable jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them firmly into the mastic. Wrap a second strip of mastic completely around the outer jacket, overlapping the embedded neutral wires. Use a third strip if necessary to build up the outer diameter. Cover all mastic with vinyl tape. Carefully remove the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor.

  4. Install the Compression Lug

    Wire brush the bare aluminum conductors immediately. Install the compression lug, rotating it to spread the inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable. Remove the insulation shield as shown in the template and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  5. Lubricate and Assemble the Elbow Housing

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Ensure the insulation remains clean and free of dirt. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  6. Connect the Concentric Neutral

    Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow, twisting it tightly without damaging the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for future elbow operation.

  7. Connect the Elbow to the Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Securely fasten a fully insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector. Insert the probe tip approximately 2 inches into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. Do not operate by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.