ABB - Installation Products 161LR-D5270 - 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products 161LR-D5270 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch.…

UPC: 075114236324


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Installation Products Loadbreak Elbow, SKU 161LR-D5270, is designed for 15kV applications and rated for 200 Amps. It accommodates cable insulation diameters ranging from 0.890 inches to 1.220 inches, providing a secure fit for a defined range of cable sizes. The integrated bi-metal compression lug ensures reliable electrical connection and is suitable for compressed stranded conductors from 4/0 AWG up to 250 AWG (or 126.67 mm²). This component is essential for terminating and connecting high-voltage power cables in electrical distribution systems. Its construction focuses on delivering dependable performance for loadbreak operations. The bi-metal lug is specifically engineered to handle the transition between different conductor materials, offering enhanced conductivity and corrosion resistance compared to single-metal alternatives. This ensures long-term operational integrity and minimizes potential failure points in critical infrastructure. The specified insulation diameter range allows for versatility in application, supporting common cable constructions within its voltage and current ratings. This product is a key component for utility, industrial, and commercial power distribution networks where reliable loadbreak connections are required.
  • 15kV Voltage Rating
  • 200 Amp Current Rating
  • Cable Insulation Diameter: 0.890" to 1.220"
  • Bi-Metal Compression Lug
  • Conductor Size: 4/0 AWG Stranded to 250 AWG Solid (126.67 mm²)

Specifications

Amperage Rating
200 A
Application
The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Blue
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Bi-Metal Compression Lug, Poly (assumed from 'Loadbreak Elbow')
Material
Housing - EPDM-Rubber
Series
161LR
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.0800 L
Package Weight (Metric)
0.9440 kg
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size 4/0 Compressed/Stranded or 250 kcmil Compacted/Solid or mmSquared Compact 125.

655LRTP-H0270-DRG

600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size 4/0 Compressed/Stranded or 250 kcmil Compacted/Solid or mmSquared Compact 125.
15KV, 200 Amp, Loadbreak Elbow with Sealing Jacket, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

161LRJS-B-5210

15KV, 200 Amp, Loadbreak Elbow with Sealing Jacket, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

161LR-D5250

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

161LR-D5240

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

161LR-D5260

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

161LR-C5260

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15KV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

161LR-C5270

15KV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

161LR-C5230

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

Frequently Asked Questions

Is the elbow ANSI certified?

Yes, the enhanced Elastimold loadbreak elbow has ANSI certification.

What standards does the elbow comply with?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant.

Does the elbow have a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

Does the elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction and improvements.

What is the current and voltage rating of the elbow?

The enhanced Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

Does the elbow have RUS acceptance?

Yes, the enhanced Elastimold 200 amp loadbreak elbow has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction and improvements.

What is the current and voltage rating of the elbow?

The enhanced Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.

Does the elbow have a no-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What standards does the elbow comply with?

The enhanced Elastimold loadbreak elbow is IEEE 386 compliant.

Is the elbow ANSI certified?

Yes, the enhanced Elastimold loadbreak elbow has ANSI certification.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation and assembly.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Wire brush, Crimp tool, Hotstick, Voltage sensing device

Supplies needed:

Lubricant (supplied with product, do not substitute), No. 14 AWG / 2.5mm copper wire (or equivalent), Appropriate connector (for neutral wires), Vinyl tape, Conductive copper tape (if using specific sealing kits), Cold shrink tube (if using specific sealing kits)

  1. Perform Pre-Installation Inspection and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; replace any damaged components if resistance is encountered. Gather all required tools and maintain a clean work area.

  2. Prepare Cable End

    Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely and taking care not to nick the conductor. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Install Compression Lug

    Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread the inhibitor, ensuring the contact threaded hole aligns with the bushing bore. Refer to the crimp chart packaged with your compression lug for recommended crimp tool information. Start the crimp at the crimp line mark and rotate 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the outside of the lug and cable.

  4. Remove Insulation Shield and Bevel

    Remove the insulation shield 6-7/8 inches (175mm) back from the cable end. Ensure the cut is straight, smooth, and squared, taking care not to cut or nick the insulation. Bevel the insulation end a maximum of 1/8 inch (5mm).

  5. Assemble Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  6. Ground the Elbow and Connect Neutral Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. If the elbow came pre-ordered with a ground wire, skip this insertion. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the grounding.

  7. Connect Elbow to Bushing Plug

    DANGER: Confirm that both the transformer and the elbow are de-energized before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. Do not operate by hand.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.