ABB - Installation Products 161LR-C5270 - 15KV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products 161LR-C5270 15KV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter 0.805 inch…

UPC: 075114236270


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LR-C5270 is a 15,000-volt, 200-ampere loadbreak elbow connector engineered for medium-voltage cable systems in utility and industrial power distribution. This elbow terminates 4/0 AWG compressed stranded or solid 250 mm² conductors with cable insulation diameters between 0.805 and 1.060 inches, providing a reliable interface for medium-voltage applications. The bi-metal compression lug ensures consistent electrical contact and mechanical integrity across temperature cycles, reducing the risk of connection failure in harsh environments. Its compact design eliminates the need for a test point, simplifying installation in confined spaces while maintaining operational safety. The absence of a test point also reduces potential failure points, enhancing long-term reliability in critical power distribution networks. This loadbreak elbow is rated for 200A continuous current and is suitable for use in 15KV class equipment, including transformers, switchgear, and pad-mounted transformers. The bi-metal lug accommodates both copper and aluminum conductors, offering versatility for diverse installation requirements.
  • 15,000V rated, 200A continuous current capacity
  • Terminates 4/0 AWG compressed stranded or solid 250 mm² conductors
  • Bi-metal compression lug for reliable electrical contact
  • Cable insulation diameter range: 0.805–1.060 inches
  • Meets ANSI C119.4 and IEEE 386 standards

Specifications

Amperage Rating
200 A
Application
The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection Type
Compression Lug
Connection Type
Bi-Metal Compression Lug
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Bi-Metal, Poly
Material
Housing - EPDM-Rubber
Series
161LR
Size
0.805-1.060 inch insulation diameter, 4/0 AWG to 250 mm² conductor
Size
Cable Insulation Diameter 0.805-1.060 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Voltage Rating
15000 V
Package Dimensions (L x W x H)
10.5 IN x 19.12 IN x 12.5 IN
Package Dimensions (L x W x H)
26.67 cm x 48.5648 cm x 31.75 cm
Package Weight (Imperial)
2.0800 L
Package Weight (Metric)
0.9440 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-C5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

161LR-C5230

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

161LR-C-5240

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

161LR-C5220

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

161LR-B5270

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

161LR-B5260

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.

161LR-D5230

15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.

161LR-C5270-SG3

15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.

Frequently Asked Questions

What voltage rating does the 161LR-C5270 support?

The 161LR-C5270 is rated for 15,000 volts (15KV) medium-voltage applications.

What conductor sizes are compatible with this elbow?

The elbow supports 4/0 AWG compressed stranded or solid 250 mm² conductors.

What is the cable insulation diameter range?

The 161LR-C5270 accommodates cable insulation diameters from 0.805 to 1.060 inches.

Does this elbow include a test point?

No, the 161LR-C5270 is designed without a test point.

What is the current rating of this elbow?

The connector is rated for 200 Amps continuous current.

What standards does this connector meet?

The 161LR-C5270 complies with ANSI C119.4 and IEEE 386 standards for loadbreak separable connectors.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, designed to terminate UD cables and connect to 15kV class loadbreak bushings.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Insulated Hotstick, Wire Brush, Crimp Tool, Wire Strippers, Suitable Capacitive Voltage Sensing Device (for 162LR)

Supplies needed:

161LR or 162LR Loadbreak Elbow Connector Kit (includes Housing, Lug, Probe, Lubricant), No. 14 AWG (2.5mm) Copper Ground Wire, Neutral Wire Connector, Vinyl Electrical Tape, Conductive Copper Tape (if applicable for cable type), Cold Shrink Sealing Kit (if applicable for cable type), Silicone Lubricant (for 162LR test point cap)

  1. De-energize and Perform Pre-Installation Checks

    DANGER: Ensure all apparatus is de-energized before beginning installation. Confirm the transformer and elbow are de-energized. Inspect all package contents for completeness and damage. Verify all components (elbow, lug, probe) are compatible with your cable and mating products. Check the probe threads by hand-threading into the compression lug; if resistance is encountered, replace the damaged component. Have all required tools ready and maintain cleanliness.

  2. Prepare Cable for Termination

    Train the cable to ensure 24-36 inches (610-914mm) of slack for operation. Cut the cable squarely at the bushing centerline. Remove 9-5/8 inches (240mm) of the outer jacket. For copper tape shield cables, remove an additional 7-1/8 inches (180mm) of the copper tape shield and wrap conductive copper tape over the end to hold it in place. For concentric neutral or drain wire cables, unwrap and bind the neutral/ground wires, folding them back and securing with vinyl tape. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable, loose end first.

  3. Prepare Conductor and Insulation

    Remove 2-1/8 inches (55mm) of the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) from the end, beveling the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation.

  4. Assemble Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for about four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.

  5. Ground Elbow and Connect Neutrals

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly. If the elbow came pre-ordered with a ground wire, skip this step. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.

  6. Connect Elbow to Bushing

    DANGER: Re-confirm that the transformer and elbow are de-energized before making the final connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. Do not operate by hand.

  7. Perform Voltage Test (162LR only)

    For 162LR models, remove the test point cap using a hotstick, peeling it off at an angle. WARNING: The test point is a capacitance device; do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.