ABB Installation Products 161LR-C5230 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch.…
UPC: 075114236225
Contact for Pricing
Minimum Qty: 15
Multiplier: 15
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage rating with 200 Amp continuous current capacity
- Accommodates cable insulation diameters from 0.805" to 1.060"
- Bi-metal compression lug for #1 to 1/0 AWG compressed stranded or solid conductors (42.41 mm²)
- Loadbreak capability for safe connection/disconnection under load
- Designed for medium-voltage power distribution systems
Specifications
Amperage Rating | 200 A |
Application | The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal, Poly |
Material | Bi-Metal Compression Lug |
Series | 161LR |
Size | Cable Insulation Diameter 0.805 inch to 1.060 inch |
Size | 0.805-1.060 inch insulation diameter, AWG #1 to 1/0 (42.41 mm²) conductor |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 15 kV |
Voltage Rating | 15000 V |
Voltage Rating | 15kV |
Package Dimensions (L x W x H) | 10.5 IN x 19.12 IN x 12.5 IN |
Package Dimensions (L x W x H) | 26.67 cm x 48.5648 cm x 31.75 cm |
Package Weight (Imperial) | 2.0700 L |
Package Weight (Metric) | 0.9390 kg |

K656YSR-H0230
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
161LR-C-5240
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
161LR-C5220
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
161LR-B5270
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
161LR-B5260
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
161LR-D5230
15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.
161LR-C5270-SG3
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What standards and certifications does this product meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
How is the no-stick interface achieved with this elbow?
The no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for both 15 kV and 25 kV applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV systems, designed to make switching operations easier for end users.
What standards and certifications does this product meet?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the U.S. Department of Agriculture (USDA).
How is the no-stick interface achieved with this elbow?
The no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for both 15 kV and 25 kV applications.
What is the Elastimold 200 amp loadbreak elbow?
It is an enhanced loadbreak elbow for 15 kV and 25 kV systems, designed to make switching operations easier for end users.
How is the no-stick interface achieved with this elbow?
The no-stick interface is achieved when the enhanced Elastimold 200 amp loadbreak elbow is used with Elastimold bushings.
What are the voltage ratings for this loadbreak elbow?
The Elastimold 200 amp loadbreak elbow is designed for both 15 kV and 25 kV applications.
How to Install the 161LR Loadbreak Elbow Connector
This guide outlines the essential steps for safely installing the 161LR Loadbreak Elbow Connector, covering cable preparation, component assembly, and grounding procedures for various UD cables.
Estimated time: 1h 30m
Tools needed:
Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick tool
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Vinyl tape, Cold shrink tube (if applicable), Copper tape (if applicable), No. 14 AWG (2.5mm) copper ground wire, Appropriate neutral wire connector
- Prepare Cable for Connection
DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all package contents and components for damage and compatibility. Train the cable to ensure adequate slack. Depending on your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions in the product manual to unwrap/bind neutral/drain wires, cut the cable squarely, and remove the outer jacket and/or copper tape shield as specified in the documentation. If using a sealing kit, slide the cold shrink tube onto the cable.
- Prepare Conductor and Insulation
Remove the shield and insulation 2-1/8 inches (55mm) from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove the insulation shield as shown in the diagram, and bevel the insulation end 1/8 inch (5mm) maximum. Thoroughly clean the insulation.
- Assemble Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding Wires
Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions to complete the grounding installation.
- Connect Elbow to Bushing Plug
DANGER: CONFIRM that both the transformer and the elbow are DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.