ABB - Installation Products 161LR-C-5240 - 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

ABB Installation Products 161LR-C-5240 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch.…

UPC: 075114234061


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 15

Multiplier: 15

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LR-C-5240 is a 15kV, 200 Amp loadbreak elbow connector designed for medium-voltage cable terminations in utility, industrial, and commercial power systems. This elbow connector features a bi-metal compression lug for secure, durable connections with copper or aluminum conductors. The integrated lug accommodates compressed stranded conductors from 1/0 AWG to 2/0 AWG (53.49 mm²) and solid conductors from 2/0 AWG, ensuring compatibility with a wide range of cable sizes. The connector is designed for cable insulation diameters between 0.805 inches and 1.060 inches, providing a precise fit for standard medium-voltage cables. The loadbreak design allows for safe, hot-line maintenance and switching operations without interrupting power flow. This product is part of ABB's Installation Products line, optimized for medium-voltage distribution systems where reliability and safety are critical. The 161LR-C-5240 is ideal for applications requiring loadbreak capabilities, such as pad-mounted transformers, switchgear, and underground distribution networks. Its robust construction and precise specifications ensure safe and efficient power transfer in demanding electrical environments. The 161LR-C-5240 is a 15KV rated device, capable of handling 200 Amps. It is a loadbreak elbow connector. The cable insulation diameter range for this connector is 0.805 inch to 1.060 inch. The connector utilizes a bi-metal compression lug. For conductor sizing, it is designed for compressed stranded conductors of 1/0 AWG and solid conductors of 2/0 AWG. The equivalent mm² for the conductor size is 53.49.
  • 15kV voltage rating, 200 Amp current capacity
  • Bi-metal compression lug for copper or aluminum conductors
  • Accommodates compressed stranded 1/0 to 2/0 AWG and solid 2/0 AWG conductors
  • Cable insulation diameter range: 0.805" to 1.060"
  • Loadbreak design enables safe hot-line maintenance and switching

Specifications

Amperage Rating
200 A
Application
The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Housing - EPDM-Rubber
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
10.5 IN x 19.12 IN x 12.5 IN
Package Dimensions (L x W x H)
26.67 cm x 48.5648 cm x 31.75 cm
Package Weight (Imperial)
2.0700 L
Package Weight (Metric)
0.9390 kg
200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

162LR-B-2240

200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Copper Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

161LR-C5220

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

161LR-B5270

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.

161LR-B5260

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 3/0 /Solid 4/0 /mmSquared 85.01.
15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.

161LR-D5230

15kV, 200 Amp, Loadbreak Elbow, without Test Point, Cable Insulation Diameter .890-1.220 inches, Bi-Medal Lug, Conductor Size #1 AWG Stranded Compressed or 1/0 AWG Compact/Solid. No Sealing Kit.
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.

161LR-C5270-SG3

15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

161LR-C5250

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

161LR-B5250

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

Frequently Asked Questions

What is the significance of RUS acceptance for this product?

Rural Utilities Service (RUS) acceptance from the USDA authorizes the use of the enhanced Elastimold 200 amp loadbreak elbow in rural infrastructure construction and improvements.

What standards and certifications does the elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What safety features does the enhanced elbow include?

It includes improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for switching operations.

What is the significance of RUS acceptance for this product?

Rural Utilities Service (RUS) acceptance from the USDA authorizes the use of the enhanced Elastimold 200 amp loadbreak elbow in rural infrastructure construction and improvements.

What standards and certifications does the elbow meet?

The enhanced Elastimold 200 amp loadbreak elbow is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What safety features does the enhanced elbow include?

It includes improved insulation for 15 kV elbows, rigid probe support, a no-stick interface with Elastimold bushings, a robust stainless-steel pulling eye, and dual grounding eye positions.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for switching operations.

What is the significance of RUS acceptance for this product?

Rural Utilities Service (RUS) acceptance from the USDA authorizes the use of the enhanced Elastimold 200 amp loadbreak elbow in rural infrastructure construction and improvements.

What is the Elastimold 200 amp loadbreak elbow?

It is an enhanced 200 amp loadbreak elbow available in 15 kV and 25 kV series, designed for switching operations.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation, cable preparation, assembly, and grounding of 161LR and 162LR Loadbreak Elbow Connectors for terminating various UD cables.

Estimated time: 1h 30m

Tools needed:

Probe wrench, Wire brush, Crimp tool (specific to compression lug), Wire strippers/cutters, Hotstick (for final connection), Screwdriver (for grounding connectors)

Supplies needed:

161LR or 162LR Loadbreak Elbow Connector Kit (includes Housing, Compression Lug, Probe, Lubricant), No. 14 AWG (2.5mm) copper wire (for grounding), Appropriate connector for neutral wires, Vinyl tape (if using jacketed cable with drain wires), Conductive copper tape (if using jacketed copper tape shield cable with 200ECS-G2/G3 kit), Cold shrink tube (if using 200ECS sealing kits)

  1. Perform Initial Safety Checks and Component Inspection

    Ensure all apparatus is de-energized before beginning installation. Inspect all components (Elbow Connector Housing, Compression Lug, Probe) for damage, proper rating, and compatibility with the cable and mating products. Check the package contents for completeness. Read the entire instructions before proceeding. DANGER: All apparatus must be de-energized during installation or removal of parts. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Based on your cable type (Non-Jacketed Concentric Neutral, Jacketed Concentric Neutral, Jacketed Cable with Drain Wires, or Jacketed Copper Tape Shield), follow the specific instructions in the product manual for preparing the neutral wires or shield, removing the outer jacket, and cutting the cable squarely at the bushing centerline. If using a sealing kit, slide the cold shrink tube onto the cable at this stage.

  3. Prepare the Conductor and Insulation

    Remove 2-1/8” (55mm) of the shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush any bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield as shown in the product diagram, and bevel the insulation end by a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; do not substitute. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  5. Ground the Elbow Connector

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to the ground using an appropriate connector, ensuring adequate slack in the wires for future elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect the Elbow to the Bushing Plug

    Before proceeding, CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, using sufficient force to engage the internal lock on the elbow connector and bushing interface. DANGER: Ensure transformer and elbow are de-energized before connecting. DO NOT OPERATE BY HAND. Use a full insulated 'hotstick' type tool.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.