The ABB 161LR-D5230 Loadbreak Elbow is a 15kV, 200 Amp rated deadbreak connector designed for underground distribution systems. This elbow connector accommodates cable insulation diameters from 0.890 to 1.220 inches and supports conductor sizes from #1 AWG stranded compressed to 1/0 AWG compact or solid. The bi-medal lug ensures compatibility with both copper and aluminum conductors, providing flexibility in system design. This unit does not include a test point or sealing kit, making it ideal for applications where these features are not required. The 161LR-D5230 is part of ABB's Installation Products line, known for reliable performance in utility and industrial power distribution networks. Its compact design and robust construction make it suitable for use in vaults, pad-mounted transformers, and switchgear where space and reliability are critical. The connector meets industry standards for loadbreak operations, allowing for safe and efficient switching under load conditions.
  • 15kV rated deadbreak connector for underground distribution
  • 200 Amp continuous current rating
  • Cable insulation diameter range: 0.890–1.220 inches
  • Bi-medal lug supports #1 AWG stranded compressed or 1/0 AWG compact/solid conductors
  • No test point or sealing kit included

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp Loadbreak Connection
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Bi-Medal Lug
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Series
161LR
Size
Cable Insulation Diameter 0.890-1.220 inches
Size
Cable Insulation Diameter 0.890 inch to 1.220 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM

54211116

6MM2 BLACK CABLE FOR DISTRIBUTION BLOCK ROW TYPE LENGTH 320MM
15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.

161LR-C5270-SG3

15kV, 200 Amp, Loadbreak Elbow with Sealing Kit, No Test Point. Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0. 200ECS-G3 Jacket Seal and Grounding Kit Included.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

161LR-C5250

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.805 inch to 1.060 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.

161LR-B5250

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

161LR-B5240

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.

755LR-K0270

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125.
35kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 1.090 to 1.310 inch, Conductor Size 3/0 Compressed/Stranded or 4/0 Compact/Solid.

755LR-K0260-SG3

35kV, 600 Amp, Deadbreak Elbow without Test Point, with Sealing Kit. Cable Insulation Diameter Range 1.090 to 1.310 inch, Conductor Size 3/0 Compressed/Stranded or 4/0 Compact/Solid.

Frequently Asked Questions

Does this elbow include a test point?

No, the 161LR-D5230 does not include a test point.

Is a sealing kit included with the 161LR-D5230?

No, the 161LR-D5230 does not come with a sealing kit.

What is the voltage rating of the 161LR-D5230?

The 161LR-D5230 is rated for 15kV maximum operating voltage.

What is the current rating of this elbow?

The elbow has a continuous current rating of 200 Amps.

What conductor sizes does this elbow support?

The elbow supports #1 AWG stranded compressed or 1/0 AWG compact/solid conductors.

What is the maximum cable insulation diameter?

The maximum cable insulation diameter is 1.220 inches.

What type of lug does the 161LR-D5230 use?

The elbow uses a bi-medal lug compatible with both copper and aluminum conductors.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, assembly, and grounding. This product is designed to terminate various UD cables and connect to 15kV class 200 ampere loadbreak bushings or accessory devices.

Estimated time: 1h

Tools needed:

Wire strippers, Cable cutting tools, Wire brush, Crimp tool (refer to lug chart), Probe wrench (supplied), Full insulated hotstick type live-line tool, Multimeter (for voltage test, if applicable)

Supplies needed:

Elbow Connector Housing (supplied), Compression Lug (supplied), Probe (supplied), Lubricant (supplied, DO NOT SUBSTITUTE), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate connector (for neutral wires to ground), Vinyl tape (for drain wires, if applicable), Cold shrink tube (if using sealing kit), Conductive copper tape (if using sealing kit), HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Perform Pre-Installation Checks and Safety Review

    DANGER: All apparatus must be de-energized during installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products. Review all safety warnings and ensure installation is performed by competent personnel trained in high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility with mating parts. Check the package contents for completeness. Verify proper fit of all components, including threading the probe into the compression lug to check for resistance. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare the Cable

    Train the cable to ensure adequate slack for ease of operation. Cut the cable squarely at the centerline of the bushing. Remove the outer jacket and/or copper tape shield according to your cable type (e.g., 9-5/8 inches of outer jacket, 7-1/8 inches of copper tape shield). Manage neutral or drain wires by unwrapping, binding, folding them back, and taping, or connect them to the tank ground using a jumper or braid. Remove the insulation shield and insulation from the cable end (e.g., 2-1/8 inches of insulation, 6-7/8 inches of insulation shield), cutting squarely and taking care not to nick the conductor. Bevel the insulation end a maximum of 1/8 inch (5mm). Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable. Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  3. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE, as other lubricants may be harmful. Keep the insulation clean of dirt and grime. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  4. Ground the Elbow Connector

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to the specific instructions supplied with that kit to complete the grounding installation.

  5. Connect the Elbow to the Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with the connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing. DO NOT HOLD IN THIS POSITION. Immediately push the elbow home with a fast, firm, straight motion. Use sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.