ABB - Installation Products 161LR-B5230-S - 15kV, 200 Amp, Loadbreak Elbow without Test Point, Cable Insulation Diameter 0.635 to 0.905 inches (16.13-22.99 mm), Bi-Metal Compression Lug, Conductor Size Stranded/Compressed #1, Solid/Compact 1/0. S is for Cold Shrinkable Jacket Seal.

ABB Installation Products 161LR-B5230-S 15kV, 200 Amp, Loadbreak Elbow without Test Point, Cable Insulation Diameter 0.635 to…

UPC: 075114324564


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LR-B5230-S is a 15kV, 200 Amp loadbreak elbow connector engineered for medium-voltage power distribution systems. This model features a cold shrinkable jacket seal (designated by 'S') for superior environmental protection and simplified installation in utility, industrial, and commercial applications. The connector accommodates cable insulation diameters from 0.635 to 0.905 inches (16.13-22.99 mm), making it compatible with a wide range of medium-voltage cables. The integrated bi-metal compression lug ensures reliable electrical connections for both stranded/compressed conductors sized #1 AWG and solid/compact conductors sized 1/0 AWG. This dual-material design provides optimal conductivity and mechanical strength, reducing the risk of connection failures in high-load environments. The loadbreak elbow is designed for applications requiring safe, load-interruptible connections without a test point, streamlining system design where testing is performed at other points in the circuit. Key specifications include a 15kV voltage rating and 200 Amp current rating, meeting the demands of medium-voltage distribution networks. The 161 Series construction delivers durability and long-term performance in outdoor and indoor environments. Proper conductor sizing and insulation diameter compatibility are critical for optimal performance and safety—refer to the ABB catalog for detailed conductor code selection (e.g., 230 for #1 AWG stranded/compressed or 240 for 1/0 AWG solid/compact). This connector is part of ABB’s Installation Products line, a trusted solution for medium-voltage infrastructure requiring dependable loadbreak connections. Its robust design minimizes maintenance needs while ensuring safe power flow in critical applications.
  • 15kV voltage rating, 200 Amp current capacity
  • Cold shrinkable jacket seal for environmental protection
  • Bi-metal compression lug for stranded/compressed #1 and solid/compact 1/0 conductors
  • Accommodates cable insulation diameters 0.635-0.905 inches (16.13-22.99 mm)
  • Loadbreak elbow without test point for simplified system design

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp Loadbreak Connection
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Connection Type
Loadbreak Elbow
Current Rating
200 A
Environmental Conditions
Fully Submersible
Insulation
True
Material
Housing - EPDM-Rubber
Material
Bi-Metal Compression Lug
Series
161LR
Size
0.635 to 0.905 inches (16.13-22.99 mm)
Size
Cable Insulation Diameter 0.635 inch to 0.905 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

161LR-B5220

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.

161LR-B5210

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

161LR-A5240

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

161LR-A5230

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

161LR-A5220

15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.

161LR-A5270

15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K151SR-C0240SG3

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

Frequently Asked Questions

What is the maximum operating voltage for this loadbreak elbow?

The ABB 161LR-B5230-S loadbreak elbow is rated for 15kV operating voltage.

What is the continuous current rating of this ABB elbow connector?

This loadbreak elbow connector has a continuous current rating of 200 Amps.

What cable insulation diameter range does this elbow support?

The elbow supports cable insulation diameters from 0.635 to 0.905 inches (16.13-22.99 mm).

What type of lug is used for conductor connection?

This loadbreak elbow features a bi-metal compression lug for conductor connection.

What does the 'S' designation signify on this elbow?

The 'S' designation indicates that this elbow has a cold shrinkable jacket seal.

Does this loadbreak elbow include a test point?

No, this specific model of loadbreak elbow does not include a test point.

What conductor sizes are compatible with the bi-metal lug?

The bi-metal compression lug is compatible with stranded/compressed #1 conductors and solid/compact 1/0 conductors.

How to Install 161LR/162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe installation and initial setup of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, lug installation, and elbow assembly.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp Tool, Wire Brush, Hotstick, Cable Cutting Tool, Wire Strippers

Supplies needed:

UD Cable, Lubricant (Do Not Substitute), Copper Wire (No. 14 AWG / 2.5mm), Appropriate Ground Connector, Vinyl Tape (if applicable), Cold Shrink Tube (if using sealing kit), Conductive Copper Tape (if using sealing kit)

  1. Perform Pre-Installation Checks and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation. This product must be installed by competent personnel trained in high-voltage safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check probe threads by threading into the compression lug; replace if resistance is encountered. Have all required tools ready and maintain cleanliness throughout the procedure.

  2. Prepare Cable for Termination

    Train the cable to ensure adequate slack for operation, typically 24-36 inches (610-914mm) beyond the bushing centerline. Prepare concentric neutral wires or drain wires according to your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), ensuring proper binding and folding back as specified in the product instructions. Cut the excess cable squarely at the centerline of the bushing. If using a sealing kit, slide the cold shrink tube onto the cable loose end first.

  3. Prepare Cable End and Install Compression Lug

    Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately. Install the compression lug, rotating to spread inhibitor, and align its threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield, ensuring a straight, smooth, and squared cut. Bevel the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt or inhibitor traces.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Keep the insulation clean. Slide the elbow connector onto the cable using a back and forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Ground the Elbow

    Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist the wire tightly, taking care not to damage the eye. If the elbow is preordered with a ground wire, skip this step. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, refer to its specific instructions.

  6. Connect the Elbow to the Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Operate the connection using a full insulated 'hotstick' type tool as per operating instructions; DO NOT OPERATE BY HAND. Consult your company's safe work practices for the required tool length.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.