ABB - Installation Products 161LR-A5220 - 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.

ABB Installation Products 161LR-A5220 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch.…

UPC: 075114236096


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 161LR-A5220 is a 15KV, 200 Amp loadbreak elbow designed for underground distribution systems. This product accommodates cable insulation diameters from 0.575 to 0.740 inches, making it compatible with a range of medium-voltage cables. The bi-metal compression lug ensures reliable electrical connections for compressed stranded #2 or solid #1 AWG conductors, or equivalent 33.62 mm² cross-sections. This loadbreak elbow is rated for 200 amperes continuous current and is engineered for safe, load-interrupting operations in underground residential, commercial, and industrial distribution networks. The elbow’s design allows for quick connection and disconnection of cables from transformers, switchgear, or other equipment without de-energizing the entire system, reducing downtime during maintenance or reconfiguration. The bi-metal compression lug provides corrosion-resistant conductivity between copper conductors and aluminum components, ensuring long-term performance in harsh environmental conditions. This product meets industry standards for medium-voltage cable accessories and is suitable for use in vaults, manholes, and direct-buried applications where space and safety are critical. Use the ABB 161LR-A5220 to upgrade or maintain 15KV class distribution systems with a proven, field-tested solution from ABB Installation Products.
  • 15KV rated, 200 Amp continuous current capacity
  • Accommodates cable insulation diameters 0.575 to 0.740 inches
  • Bi-metal compression lug for copper-to-aluminum compatibility
  • Supports compressed stranded #2 or solid #1 AWG conductors (33.62 mm²)
  • Loadbreak design enables safe connection/disconnection under load

Specifications

Amperage Rating
200 A
Application
The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Current Rating
200 A
Environmental Conditions
Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water
Insulation
True
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
161LR
Size
Cable Insulation Diameter 0.575 inch to 0.740 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector
Voltage Rating
15 kV
Voltage Rating
15kV
Package Dimensions (L x W x H)
10.5 IN x 19.12 IN x 12.5 IN
Package Dimensions (L x W x H)
26.67 cm x 48.5648 cm x 31.75 cm
Package Weight (Imperial)
0.1300 L
Package Weight (Metric)
0.0590 kg
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug

162LR-B-5220

15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .635 inch - .905 inch Cable Insulation Diameter, #2 Stranded Wire Size. Bi-Metal Compression Lug
15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.

161LR-A5270

15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K151SR-C0240SG3

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K151SP-A0250-SG3

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K151SP-C0240SG3

200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.

K151SR-A0250-SG3

200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

274RLR-G5230

200 Amp, 25kV, Loadbreak Replacement Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

168ELR-7495-5220

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.740 inch to 0.950 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2 or Solid #1 or mmSquared 33.62.

Frequently Asked Questions

What is the significance of RUS acceptance for this product?

RUS acceptance from the USDA authorizes its use in rural infrastructure construction and improvements.

Does the elbow have a non-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What certifications does the Elastimold elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current and voltage rating of the elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available in 15 kV and 25 kV series.

What is the significance of RUS acceptance for this product?

RUS acceptance from the USDA authorizes its use in rural infrastructure construction and improvements.

Does the elbow have a non-stick interface?

Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.

What certifications does the Elastimold elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

What is the current and voltage rating of the elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available in 15 kV and 25 kV series.

What is the current and voltage rating of the elbow?

The Elastimold loadbreak elbow is rated for 200 amps and is available in 15 kV and 25 kV series.

What certifications does the Elastimold elbow have?

The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance.

How to Install 161LR and 162LR Loadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of Elastimold 161LR and 162LR Loadbreak Elbow Connectors on various UD cables, including cable preparation, elbow assembly, grounding, and initial connection to a bushing.

Estimated time: 1h

Tools needed:

Wire strippers, Cable cutting tools, Wire brush, Crimp tool, Probe wrench, Hotstick, Suitable voltage sensing device (for 162LR)

Supplies needed:

161LR or 162LR Elbow Connector Kit (includes housing, lug, probe, lubricant), No. 14 AWG / 2.5mm copper wire, Appropriate connector for neutral wires, Vinyl tape (if applicable for cable type), Cold shrink tube (if using sealing kit), Conductive copper tape (if using specific sealing kits)

  1. Perform Initial Inspection and Safety Checks

    DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; replace if resistance is encountered. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors before energizing or submerging.

  2. Prepare the Cable for Termination

    Train the cable to ensure adequate slack for operation. Follow the specific instructions for your cable type (non-jacketed concentric neutral, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) to prepare the neutral wires or grounding braid, remove the outer jacket, and cut the cable squarely at the bushing centerline. If using a sealing kit, slide the cold shrink tube onto the cable at this stage. Bind and fold back ground wires if applicable, securing with vinyl tape.

  3. Prepare Conductor and Insulation

    Remove 2-1/8 inches (55mm) of shield and insulation from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore and crimp according to the crimp chart, rotating 180 degrees for each successive crimp. Carefully wipe off excess inhibitor. Remove 6-7/8 inches (175mm) of the insulation shield, beveling the insulation end by a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all dirt and inhibitor.

  4. Assemble the Elbow Connector

    Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.

  5. Connect Grounding and Neutral Wires

    Insert one end of a separate No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.

  6. Connect Elbow to Bushing Plug

    DANGER: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.

  7. Verify De-energization (162LR with Test Point Only)

    For 162LR connectors equipped with a test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The test point is a capacitance device and not directly connected to the conductor; use a suitable sensing device made for capacitive test points. Follow the meter manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.