ABB Installation Products 161LR-B5220 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch.…
UPC: 075114236140
Contact for Pricing
Minimum Qty: 15
Multiplier: 15
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV voltage rating
- 200 Amp current rating
- Accommodates cable insulation diameter from 0.635" to 0.905"
- Bi-metal compression lug for reliable termination
- Suitable for #2 AWG stranded or #1 AWG solid conductors (33.62 mm²)
Specifications
Amperage Rating | 200 A |
Application | The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Connection Type | Loadbreak Elbow |
Current Rating | 200 A |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Compression Lug |
Series | 161LR |
Size | 0.635 to 0.905 inch |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 10.5 IN x 19.12 IN x 12.5 IN |
Package Dimensions (L x W x H) | 26.67 cm x 48.5648 cm x 31.75 cm |
Package Weight (Imperial) | 2.0900 L |
Package Weight (Metric) | 0.9480 kg |

K655LR-F5220
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
161LR-B5210
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67.
161LR-A5240
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
161LR-A5230
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
161LR-A5220
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
161LR-A5270
15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.
K151SR-C0240SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
K151SP-A0250-SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What is the maximum operating voltage for this loadbreak elbow?
The ABB 161LR-B5220 loadbreak elbow is rated for 15KV operation.
What conductor sizes can be used with this ABB loadbreak elbow?
This elbow is designed for compressed stranded AWG #2 or solid AWG #1 conductors, equivalent to 33.62 mm².
What is the cable insulation diameter range for this elbow?
The 161LR-B5220 accommodates cable insulation diameters from 0.635 inches to 0.905 inches.
What type of lug does the 161LR-B5220 feature?
It features a bi-metal compression lug for secure and durable electrical connections.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and preparation of 161LR and 162LR Loadbreak Elbow Connectors, designed for terminating UD cables and connecting to 15kV class loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Hotstick (live-line tool), Suitable sensing device for capacitive test points
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector for neutral wires, Vinyl tape (optional), Cold shrink tube (optional), Conductive copper tape (optional)
- Initial Inspection and Safety Precautions
Before beginning, ensure all apparatus are de-energized. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check the probe threads by hand-threading into the compression lug; replace if resistance is encountered. Ensure all required tools are at hand and maintain a clean work area. This installation must be performed by competent personnel trained in high voltage electrical equipment safety.
- Prepare the Cable for Termination
Train the cable to ensure sufficient slack for ease of operation. Cut the cable squarely at the bushing centerline. Refer to the specific cable type instructions (e.g., non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield) in the documentation to remove the outer jacket and prepare neutral or drain wires as required. For most jacketed cables, remove 9-5/8 inches (240mm) of the outer jacket.
- Prepare Conductor and Insulation
Remove the insulation shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the lug so its threaded hole aligns with the bushing bore. Crimp the lug according to the manufacturer's chart, starting at the crimp line and rotating 180 degrees for successive crimps. Carefully wipe off any excess inhibitor. Remove the insulation shield 6-7/8 inches (175mm) back from the cable end, beveling the insulation end by 1/8 inch (5mm) maximum. Thoroughly clean the insulation to remove all dirt and inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; do not substitute. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.
- Connect Grounding Wires
Insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the elbow and twist tightly, taking care not to damage the eye. If the elbow came with a pre-attached ground wire, skip this step. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If using a cold shrink grounding kit, follow its specific instructions.
- Connect Elbow to Bushing Plug
CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Securely fasten a hotstick to the loadbreak connector pulling eye. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion to engage the internal lock. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.