ABB Installation Products 161LR-A5240 15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch.…
UPC: 075114236119
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15KV voltage rating for 13.8KV class systems
- 200A continuous current rating
- Loadbreak design for safe hot-stick operation
- Bi-metal compression lug for reliable electrical and mechanical performance
- Compatible with 1/0-2/0 AWG stranded/solid conductors (53.49 mm²)
- Cable insulation diameter range: 0.575" to 0.740"
- Part of ABB's Installation Products line for underground distribution
Specifications
Amperage Rating | 200 A |
Application | The 161LR is designed for Connecting to and Operating 15kV Class, 200 Amp Distribution apparatus. It Provides a Convenient Method to Connect/Disconnect Cable and Equipment on Power Distribution Systems |
Color | Black |
Conductor Range | 1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG |
Environmental Conditions | Products are designed and constructed for all applications including Padmount, Subsurface, Vault, Indoor, Outdoor, Direct Sunlight, Direct Buried and Continuously Submerged in Water |
Insulation | True |
Material | Housing - EPDM-Rubber |
Special Features | Fully Shielded, Fully Submersible Molded Rubber Housing, 100 Percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Provision for Hot Stick Operation. Provision for Ground Wire Connection |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.0800 L |
Package Weight (Metric) | 0.9440 kg |

162LR-C5240
15kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, 1/0 Stranded Wire Size, Bi-Metal Compression Lug
161LR-A5230
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
161LR-A5220
15KV, 200 Amp, Loadbreak Elbow, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded #2/Solid #1/mmSquared 33.62.
161LR-A5270
15KV, 200 Amp, Loadbreak Elbow, Without Test Point, Cable Insulation Diameter 0.575 inch to 0.740 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250.
K151SR-C0240SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 or Solid 2/0 or mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
K151SP-A0250-SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.
K151SP-C0240SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G3 Jacket Seal and Grounding Kit Included.
K151SR-A0250-SG3
200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 or Solid 3/0 or mmSquared 67.43. 200ECS-G3 Jacket Seal and Grounding Kit Included.Frequently Asked Questions
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
How does the elbow ensure a non-stick interface?
A no-stick interface is achieved when the enhanced loadbreak elbow is used with Elastimold bushings, as tested by NEETRAC.
What are the current and voltage ratings?
The enhanced Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.
What is the Elastimold loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow, available for 15 kV and 25 kV applications.
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
How does the elbow ensure a non-stick interface?
A no-stick interface is achieved when the enhanced loadbreak elbow is used with Elastimold bushings, as tested by NEETRAC.
What are the current and voltage ratings?
The enhanced Elastimold loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.
What is the Elastimold loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow, available for 15 kV and 25 kV applications.
What certifications does the loadbreak elbow have?
The product is IEEE 386 compliant, ANSI certified, and has Rural Utilities Service (RUS) acceptance from the USDA.
What is the Elastimold loadbreak elbow?
It is an enhanced 200 amp loadbreak elbow, available for 15 kV and 25 kV applications.
How to Install 161LR/162LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 161LR and 162LR Loadbreak Elbow Connectors, including cable preparation, assembly, and connection to a bushing.
Estimated time: 1h 30m
Tools needed:
Cable cutting tool, Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick tool, Measuring tape
Supplies needed:
161LR or 162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied, do not substitute), No. 14 AWG / 2.5mm copper ground wire, Appropriate neutral wire connector, Vinyl tape (if applicable), Conductive copper tape (if applicable), Mating 15kV class loadbreak bushing, Cleaning supplies
- Verify Safety and Components
DANGER: Ensure all apparatus is de-energized before beginning installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all package contents and components for completeness, damage, proper fit with cable and mating products. Check probe threads by threading into the compression lug; replace if resistance is encountered. Have all required tools ready and maintain cleanliness.
- Train and Prepare Cable
DANGER: Ensure all apparatus is de-energized. Train the cable to ensure adequate slack for operation. Depending on your specific cable type (non-jacketed/jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the detailed instructions in the product documentation. This involves unwrapping neutral wires, removing the outer jacket, or removing the copper tape shield to the specified lengths, and cutting the cable squarely at the bushing centerline. If applicable, install cold shrink tubes or wrap conductive copper tape as instructed for your cable type.
- Prepare Cable End and Install Compression Lug
Remove 2-1/8 inches (55mm) of the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor and ensure the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove 6-7/8 inches (175mm) of the insulation shield, beveling the insulation end a maximum of 1/8 inch (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble Elbow and Probe
Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; do not substitute. Keep the insulation clean. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off any excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow Connector
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring adequate slack for elbow operation. If your elbow was preordered with a ground wire or if you are using a cold shrink grounding kit, follow those specific instructions.
- Connect Elbow to De-energized Bushing
DANGER: CONFIRM THAT BOTH THE TRANSFORMER AND THE ELBOW ARE DE-ENERGIZED BEFORE PROCEEDING. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Attach a hotstick tool securely to the loadbreak connector pulling eye. Remove any insulated cap from the bushing using the hotstick. Withdraw the elbow from its parking stand with a fast, straight, firm motion. Insert the probe tip approximately 2 inches (50mm) into the bushing, then immediately push the elbow home with a fast, firm, straight motion, applying sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.