ABB Installation Products 1601EA4-H 200 Amp, 15kV, Loadbreak Extended Insert Bushing. Customer Special
UPC: 783786470297
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 200 Amp current rating
- 15kV voltage rating
- Loadbreak extended insert design
- ABB Installation Products manufacturer
- Customer special item for specific applications
Specifications
Application | 15 kV, 200 Amps |
Current Rating | 200 A |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Extended Insert Bushing |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.7800 L |
Package Weight (Metric) | 1.2610 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
151-SRC-1AX
200 Amp, 15/25kV, Straight Receptacle Pin Contact and Crimp Barrel Assembly. Wire Size #2 Stranded.
151-SRC-0AX
200 Amp, 15/25kV, Straight Receptacle Pin Contact and Crimp Barrel Assembly. Wire Size #1 Stranded.Frequently Asked Questions
What items are included in the 1601EA4 kit?
Each kit contains one 1601EA4 Bushing Insert, a 1601-APC-1 Protective shipping cap, 82-08 Lubricant, and IS-361 Installation Instruction.
What type of insulation does the 1601EA4 use?
The 1601EA4 uses peroxide-cured insulation and jacket.
How much longer is the 1601EA4 than the standard 1601A4?
The 1601EA4 is 3.75 inches (95mm) longer than the standard 1601A4 Bushing Insert.
What is the corona extinction voltage?
The corona extinction voltage is 11kV AC at 3pC sensitivity.
What is the 15-minute DC withstand voltage?
The 15-minute DC withstand voltage is 53kV.
What is the one-minute AC withstand voltage?
The one-minute AC withstand voltage is 34kV.
What is the BIL impulse withstand rating?
The BIL impulse withstand rating is 95kV (1.2 x 50 microsecond wave).
What apparatus is the 1601EA4 compatible with?
The 1601EA4 can connect shielded cable to sub-surface transformers, generators, pad mounted transformers, regulators, switchgear, and reclosers.
What is the maximum phase-to-phase voltage?
The maximum phase-to-phase voltage for the 15kV class is 14.4kV.
What is the maximum phase-to-ground operating voltage?
The maximum phase-to-ground operating voltage for the 15kV class is 8.3kV.
How to Install the 1601EA4-H Loadbreak Bushing Insert
Instructions for installing the 1601EA4-H Loadbreak Bushing Insert into apparatus for 15kV class loadbreak connections.
Estimated time: 30m
Tools needed:
Assembly tool (200AT), Rod or suitable tool for turning assembly tool, Wire strippers, Pliers
Supplies needed:
Loadbreak Bushing Insert, Lubricant (supplied), Copper wire (No. 14 AWG or equivalent), Suitable connector for system ground, Insulated cap(s) or connector(s) (if not immediately mating), Protective shipping cover(s) (if supplied)
- Inspect and Prepare Bushing Well
Ensure the apparatus bushing well is dry and free from contaminants. Remove the protective shipping cap from the bushing insert. Lubricate the bushing well interface area of the bushing insert with the supplied lubricant. Do not substitute lubricants.
- Install Bushing Insert
Place the lubricated bushing insert into the apparatus bushing well. Hand tighten clockwise until it bottoms. If using the 200AT assembly tool, insert it into the bushing insert bore until fully seated. Insert a suitable rod through the tool's eye and turn clockwise until the tool ratchets, indicating proper torque. Remove the tool.
- Connect Grounding Wire
Thread a length of copper wire (No. 14 AWG or equivalent) through one of the grounding tabs on the bushing insert. Create a small, tight loop, being careful not to damage the tab. Connect the free end of the wire to the system ground using a suitable connector. Ensure the grounding wire does not contact bushing interfaces or interfere with accessory placement.
- Prepare for Mating Product Installation
Thoroughly wipe the bushing interface clean of any contaminants and lubricate it with the supplied lubricant. If a mating product (elbow connector, insulated cap, or grounding elbow connector) will not be immediately installed, replace the protective shipping cap. Do not energize or submerge the apparatus with the shipping cap in place, as it is not insulated or watertight.
- Verify Full Seating
When an insulated cap or elbow is fully assembled, no portion of the red interface sleeve should be visible when viewed from the side. This indicates full elbow seating.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.