ABB - Installation Products 151-SRC-1AX - 200 Amp, 15/25kV, Straight Receptacle Pin Contact and Crimp Barrel Assembly. Wire Size #2 Stranded.
ABB - Installation Products

151-SRC-1AX

UPC: 783786630509


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Overview

The ABB 151-SRC-1AX is a high-current, medium-voltage straight receptacle pin contact and crimp barrel assembly designed for 200 Amp applications at 15/25kV. This component features a #2 stranded wire termination, ensuring reliable electrical connectivity in industrial power distribution systems. The assembly is optimized for medium-voltage switchgear, transformers, and motor control centers where high-current terminations are required. With a robust design, it accommodates stranded copper conductors, providing secure mechanical and electrical connections. The straight receptacle pin contact ensures proper alignment and mating with corresponding connectors, reducing installation time and minimizing risk of misalignment. Suitable for environments requiring medium-voltage power distribution, this assembly meets stringent industrial standards for durability and performance. The crimp barrel design allows for efficient termination of #2 AWG stranded wire, ensuring long-term reliability under high-load conditions.
  • 200 Amp rated current for high-power applications
  • 15/25kV medium-voltage compatibility
  • Straight receptacle pin contact for secure mating
  • Crimp barrel for #2 stranded wire termination
  • Designed for industrial power distribution systems

Specifications

Application
15/25 kV, 200 Amps
Connection
Compression
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Straight Replacement Contact
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.1100 L
Package Weight (Metric)
0.0500 kg
15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps

K650RTW

15/25kV 600 Series Deadbreak Reducing Tap Well. Length 5.37 inch. Width 3 inch not counting bracket. 600/200 Amps
Plastic Drive Stop® for 7/16" Cable (#4 Wire), Gray

DRIVESTOP4

Plastic Drive Stop® for 7/16" Cable (#4 Wire), Gray
HMI door mounting kit with 15M cable

181B2258

HMI door mounting kit with 15M cable
Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V

103350-4

Polarizing Cover / Hermaphroditic Cover, Black, Nylon, 8 Position, AMPMODU IV/V
3-way Junction Hardware Package Brackets and Straps only

164J3-6

3-way Junction Hardware Package Brackets and Straps only
200 Amp, 15kV, 4-Point Junction rubber only without straps.

164J4-4

200 Amp, 15kV, 4-Point Junction rubber only without straps.
4-Way Junction Hardware package Brackets and Straps only

164J4-6

4-Way Junction Hardware package Brackets and Straps only
2-Way Junction Hardware package Brackets and Straps only

164J2-6

2-Way Junction Hardware package Brackets and Straps only

Frequently Asked Questions

What wire size does this assembly support?

The assembly supports #2 AWG stranded copper wire.

What is the maximum voltage rating?

The assembly is rated for 15/25kV medium-voltage applications.

What is the current rating of this assembly?

The assembly is rated for 200 Amps.

Is this assembly suitable for stranded wire?

Yes, the crimp barrel is designed for #2 stranded copper wire.

Where is this assembly typically used?

This assembly is used in medium-voltage switchgear, transformers, and motor control centers.

How to Install the 151SR/K151SR Straight Receptacle

This guide provides step-by-step instructions for preparing the cable, crimping the conductor, and assembling the 151SR/K151SR Straight Receptacle for high-voltage electrical connections.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Rag, Approved solvent

Supplies needed:

Conductor Contact (male), Nylon Venting Rod, Lubricant (supplied), Crimp barrel, Inhibitor, Silicone grease, Elastimold bail, #14 AWG copper wire (customer supplied), Sealing material

  1. Perform Safety Checks and Prepare Components

    Ensure all apparatus is de-energized before beginning installation. Inspect all package contents and components for completeness, damage, proper fit, rating, and compatibility with mating parts. Have all required tools ready and maintain cleanliness throughout the procedure. This product must be installed only by competent personnel trained in high-voltage electrical safety practices.

  2. Prepare Cable Jacket and Shield

    For jacketed concentric neutral cable, cut and remove the cable jacket 8 inches from the cable end, ensuring sufficient concentric neutral wires for grounding. For copper tape shield cable, cut and remove the cable jacket 7 1/2 inches from the cable end, then remove the copper tape shield 6 1/2 inches from the cable end. Follow specific instructions for ECS or MA grounding devices if applicable.

  3. Prepare Conductor and Crimp Terminal

    Remove 7/8 to 1 inch of cable insulation and conductive shield (1 3/4 to 1 7/8 inches for #1 stranded/compressed and #1/0 compressed/solid aluminum cable). Cut the conductor squarely, do not pencil. Wire brush bare aluminum conductors and immediately insert them into the crimp barrel containing inhibitor. Crimp the socket terminal onto the bared conductor, ensuring it is fully seated. Start crimps at the crimp line and rotate each successive crimp 90 degrees. Wipe excess inhibitor from aluminum cable contacts and insulation.

  4. Prepare Insulation and Clean Cable

    Remove the semi-conductive shield 7 9/16 to 7 5/8 inches back from the end of the pin with a straight, smooth, squared cut, taking care not to cut or nick the insulation. Pencil the insulation 1/8 inch. Clean the outer jacket and thoroughly clean the insulation with a rag wet with an approved solvent, wiping from the cable end towards the outer jacket to remove all traces of semi-conducting residue.

  5. Lubricate and Insert Cable into Receptacle

    Remove the protective cap from the straight receptacle, keeping the cable insulation and receptacle clean. Apply the supplied lubricant sparingly to the cable and the inside of the housing; do not substitute lubricants. Push the cable into the housing until the base of the pin chamfer is flush with the inside face of the receptacle. If not connecting immediately, replace the protective cover (note: shipping cover is not an insulating device).

  6. Connect to Mating Plug

    Lubricate the nose of the mating plug with silicone grease. Place the nylon rod into the receptacle face until it bottoms (approximately 1 3/4 inches), ensuring the rod is not cut. Insert the plug assembly into the receptacle as far as possible. Pull out the nylon rod. Secure the electrical connection using an Elastimold bail.

  7. Ground the Cable

    If not using an ELASTIMOLD grounding device, connect a length of customer-supplied #14 AWG copper wire (or equivalent) through the grounding tab and twist tightly. Connect the grounding assembly of the connector to the system ground by merging it with the cable shield of each cable. Seal all grounding wires and connections to prevent corrosion.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.