ABB Installation Products 15PCJ1F1210 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786639069
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV rated power cable joint
- Accommodates insulation diameters from 0.640" to 0.820"
- Supports stranded #3 AWG or solid #2 AWG aluminum conductors
- Single-piece housing design for simplified installation
- Provides mechanical protection and environmental sealing
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | #3 STR AWG , #2 SOL AWG |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Material | Aluminum Conductor |
Number Of Conductors | 2 |
Size | 14-3/8 inch long |
Size | 0.640-0.820 inch insulation diameter, #3/#2 AWG |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8600 L |
Package Weight (Metric) | 0.3900 kg |

15PCJ2F1210
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F2200
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.
15PCJ1F1220-1210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1F1270
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1-J2280
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.
69TCJS44
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4Frequently Asked Questions
What voltage classes are available for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What is the BIL impulse withstand for a 15 kV class joint?
For a 15 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 110 kV.
How is a catalog number constructed for a transition joint?
When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.
Can copper connectors be used on aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductor only and should not be used on aluminum conductors.
What type of connector is used for aluminum to copper splicing?
An aluminum compression connector is suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
What is the DC withstand during installation for a 25 kV joint?
For a 25 kV class joint, the DC withstand during installation is 80 kV.
What is the corona extinction voltage for a 35 kV class joint?
For a 35 kV class joint, the corona extinction voltage with 3 pC sensitivity is 30 kV.
What is the short-time current rating for PCJ joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating for PCJ joints?
The continuous current rating for PCJ power cable joints is equal to that of the cable rating.
Where can Elastimold PCJ power cable joints be installed?
These joints provide a permanent, fully shielded, fully submersible splice. They can be installed in direct-burial, underground vault, and even overhead applications.
How to Install the 15PCJ1F1210 Single Core Joint
This guide provides step-by-step instructions for the safe and proper installation of the 15PCJ1F1210 Single Core Joint for extruded solid dielectric cables. It covers cable preparation, connector installation, and joint housing assembly.
Estimated time: 2h
Tools needed:
Wire brush, Cleaning solvent, Clean cloth, Crimping tool, Heat gun, Sandpaper, Soldering iron (or constant force spring tool)
Supplies needed:
Joint Housing, PVC tape, Conductor splice, Lubricant, Flat copper braid, Mastic tape, Heat shrink tubing
- Perform Initial Safety Checks and Prepare Workspace
DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. Inspect all parts for damage, correct rating, and compatibility. Read the entire instructions and have all required tools and supplies at hand. Maintain cleanliness throughout the procedure.
- Prepare Cable Jackets and Metallic Shields
Train cables into final position and square cut, leaving approximately 5mm between them. Store the heat shrink on one cable. Remove the jackets of both cables to the specified dimensions (e.g., 405mm for 1F-1G). Carefully remove the cable metallic tape screen for the specified distance (e.g., 125mm for 1F-1G) and secure the ends with PVC tape, ensuring it stays on the copper tape and does not overlap the non-metallic screen.
- Remove Non-Metallic Screen and Prepare Insulation
WARNING: Do not nick, cut, or damage the insulation surface or conductor strands. Carefully remove the non-metallic screen from both cables to the specified point (e.g., 45mm for 1F-1G). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for 1F-1G) from the end of both cables, but do NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for 1F-1G) to locate the splice later.
- Prepare Cable 1 and Temporarily Store Joint Housing
Apply one layer (half-lapped) of PVC tape over the metallic screen on Cable 1, starting at the jacket and extending 10mm beyond the metallic screen end. WARNING: Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm for 1F-1G). Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, non-metallic screen, and PVC taped metallic screen portion of Cable 1. Store the joint housing onto Cable 1, sliding it up to the jacket, ensuring it is NOT stored on the exposed metallic tape shield.
- Remove Cable Insulation
Carefully remove the cable insulation from both Cable 1 and Cable 2 to dimension 'E' (e.g., 45mm for 1F-1G). WARNING: Do NOT cut or nick the cable insulation or conductor during this process.
- Install and Crimp the Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert both conductors fully into the conductor splice. Before crimping, check the distance between insulations; if it exceeds the 'Before' dimension (e.g., 108mm for 1F-1G), do not proceed and review instructions. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions, burrs, metal chips, or filings from the splice joint area. Wipe off all excess inhibitor. After crimping, re-check the distance between cable insulations; if it exceeds the 'After' dimension (e.g., 102mm for 1F-1G), do not proceed and review instructions.
- Clean and Lubricate Cable Cores
WARNING: Remove all contaminants from the surface of the insulation. Clean the conductor, connector, and Cable 2 insulation surfaces using cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces with the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Position the Joint Housing
Slide the joint housing over the crimped connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on both sides to ensure it is equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape on each side.
- Restore the Cable Screen
Wrap flat copper braid around each joint housing, extending the ends over the metallic tape screen for 20mm on each side. Securely attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.
- Restore the Outer Jacket with Heat Shrink
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds, ensuring you DO NOT BURN THE CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink (previously stored on Cable 1) over the center of the assembly and shrink it, starting from the center and working towards the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.