ABB Installation Products 15PCJ1F1240 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786649792
Contact for Pricing
Minimum Qty: 30
Multiplier: 30
*Contact for lower quantities*
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully shielded, fully submersible straight splice for 15kV applications.
- Accommodates cable insulation diameters from 0.640" to 0.820".
- Supports 1/0 AWG stranded and 2/0 AWG solid aluminum conductors.
- Single-piece molded rubber housing with conductive shield for deadfront construction.
- Rated per IEEE Standard 404 with 110kV BIL and 35kV AC withstand.
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 1/0 STR AWG , 2/0 SOL AWG |
Connection | Compression |
Connection Type | Pin-and-socket interlock |
Current Rating | 35 kA (short-time) |
Insulation | Yes |
Material | EPDM Rubber |
Material | Rubber, Aluminum |
Number Of Conductors | 2 |
Series | 15PCJ1 |
Size | 14-3/8 inch long |
Size | 0.640-0.820 inch (Insulation Diameter) |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.8400 L |
Package Weight (Metric) | 0.3810 kg |

15PCJ1F2240
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ1F1210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1230
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15PCJ1F2200
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.
15PCJ1F1220-1210
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ1F1220
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ1F1270
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15PCJ1-J2280
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.Frequently Asked Questions
How do you order a transition joint for different cable sizes?
When ordering a transition joint for two different-size cables, list the larger connector first and the smaller connector second in the catalog number.
Can copper connectors be used on aluminum conductors?
No, copper compression connectors are suitable for splicing copper conductors to copper conductor only and should not be used on aluminum conductors.
What conductors can aluminum compression connectors splice?
Aluminum compression connectors can splice aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
What is the short-time current rating of PCJ joints?
The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What is the continuous current rating of PCJ joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What safety standards do PCJ joints meet?
The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.
Where are Elastimold PCJ joints manufactured and tested?
Elastimold PCJ power cable joints are assembled and 100% factory tested in Albuquerque, New Mexico, USA.
What pull force can the PCJ interlock withstand?
The pin-and-socket interlock in PCJ joints can withstand a pull force of up to 500 lb.
Where can PCJ power cable joints be installed?
PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, and fully submersible splice.
What voltage classes are PCJ joints available in?
PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
How to Install a Single Core Cable Joint (15PCJ1F1240)
This guide provides step-by-step instructions for installing the 15PCJ1F1240 Single Core Joint on extruded solid dielectric cables. It covers cable preparation, connector installation, and joint housing restoration for a permanent, fully screened, and submersible connection.
Estimated time: 2h
Tools needed:
Wire brush, Cleaning solvent, Clean cloth, Crimping tool, Soldering iron (optional), Constant force spring tool (optional), Sandpaper, Heat gun, Measuring tape or ruler
Supplies needed:
Joint Housing, PVC tape (multiple colors), Conductor splice (copper or aluminum compression connector), Lubricant, Flat copper braid, Mastic tape, Heat shrink tubing
- Perform Initial Safety Checks and Gather Materials
DANGER: Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. Inspect all parts for damage, rating, and compatibility with mating parts. Read the entire instructions, have all required tools at hand, and maintain cleanliness throughout the procedure.
- Prepare Cable Jackets and Metallic Shields
Train the cables into their final position and square cut, leaving approximately 5mm between them. Store the heat shrink on either cable. Remove the jackets of both cables to the specified 'A' dimension (e.g., 405mm for 1F-1G). Carefully remove the cable metallic tape screen for the specified 'B' dimension (e.g., 125mm for 1F-1G) and secure the ends with PVC tape. Keep the PVC tape on the copper tape, do not overlap onto the non-metallic screen.
- Prepare Non-Metallic Screens and Cable Insulation
WARNING: DO NOT NICK, CUT, OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the specified 'D' dimension (e.g., 45mm for 1F-1G). Bevel the edge of Cable 1. Cut the insulation to the conductor to the 'E' dimension (e.g., 150mm for 1F-1G) from the end of both cables, but DO NOT remove this insulation yet. Install a PVC tape marker on Cable 2 to the 'B' dimension to locate the splice later.
- Temporarily Store the Joint Housing
Beginning at the jacket and proceeding 10mm beyond the end of the metallic screen, apply one layer (half lapped) of PVC tape over the metallic screen on Cable 1. WARNING: Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing. Install a different color PVC tape marker on Cable 1 to the 'B' dimension. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and the PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket; DO NOT store the splice housing on the exposed metallic tape shield.
- Remove Cable Insulation
Carefully remove the cable insulation from both cables to the 'E' dimension. Ensure you DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.
- Install the Conductor Splice
Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between insulations; if it exceeds the 'Before' dimension in the table (e.g., 108mm for 1F-1G), DO NOT PROCEED, review instructions and redo. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and ensure metal chips or filings are removed from the splice joint assembly area. Wipe off all excess inhibitor. Check the distance between cable insulations again; if it exceeds the 'After' dimension (e.g., 102mm for 1F-1G), DO NOT PROCEED, review instructions and redo.
- Clean and Lubricate the Core
WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant, wiping towards the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.
- Position the Joint Housing
Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker on each side; the distance 'X' should be equal. Remove the PVC tape applied in Step C to expose 25mm of copper tape.
- Restore the Screen
Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.
- Restore the Outer Jacket
Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds; WARNING: DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.