Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1F1230 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

ABB Installation Products 15PCJ1F1230 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786635023


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 30

Multiplier: 30

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Installation Products 15kV Power Cable Joint, SKU 15PCJ1F1230, is designed for reliable cable termination in electrical distribution systems. It features a single-piece housing for simplified installation and robust protection. The joint is engineered to accommodate cable insulation diameters ranging from 0.640 inches to 0.820 inches, making it suitable for a variety of medium-voltage applications. The UNSPSC code for this product is 39121452. This joint style ensures secure and insulated connections, crucial for maintaining the integrity and safety of power transmission infrastructure. Its construction is focused on delivering dependable performance in industrial and utility settings where consistent power delivery is paramount. The single-piece housing design streamlines the connection process, reducing potential points of failure and installation time. ABB's commitment to quality in their Installation Products line ensures this joint meets the functional requirements for medium-voltage cable systems.
  • 15kV Voltage Rating
  • Single Piece Housing Design
  • Cable Insulation Diameter: 0.640" - 0.820"
  • ABB Installation Products Manufacturer

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#1 STR AWG , 1/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Material
Aluminum Conductor
Number Of Conductors
2
Series
15PCJ1F
Size
14-3/8 inch long
Size
0.640 inch to 0.820 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8600 L
Package Weight (Metric)
0.3900 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ1F2230

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ1F2200

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F1220-1210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1F1220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1F1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1-J2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4

69TCJS44

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

69TCJS44B54P45SLNNB

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

Frequently Asked Questions

What is the corona extinction voltage for the 35 kV class?

The corona extinction voltage (3 pC sensitivity) for the 35 kV class is 30 kV.

What voltage classes are available for PCJ power cable joints?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of conductors are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors, supporting sizes up to 1250 kcmil.

What are the two styles of PCJ power cable joints used for?

Style 1 is for straight splicing of two similar cables. Style 2 uses separate adapters for transition splicing between different cable sizes.

What pull force can the PCJ joint interlock withstand?

The pin-and-socket interlock design of the PCJ power cable joint can withstand a pull force of up to 500 lb.

Which industry standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating of PCJ power cable joints?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

Which connector type is used for aluminum conductors?

Kits for aluminum conductors include an aluminum compression connector suitable for aluminum-to-aluminum or aluminum-to-copper splicing.

Which connector type is used for copper conductors?

Kits for copper conductors include a copper compression connector, suitable for copper-to-copper connections only. Do not use on aluminum.

How to Install the 15PCJ1F1230 Single Core Joint

This guide provides step-by-step instructions for the permanent installation of the 15PCJ1F1230 single core joint on extruded solid dielectric cables. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.

Estimated time: 2h

Tools needed:

Wire strippers, Utility knife, Measuring tape, Wire brush, Crimping tool, Sanding tool, Heat gun, Cleaning solvent, Clean cloth, Soldering equipment (optional), Constant force spring tool (optional)

Supplies needed:

PVC tape (various colors), Lubricant, Conductor splice (compression connector), Flat copper braid, Mastic tape, Heat shrink tubing, Soldering supplies (optional), Constant force springs (optional)

  1. Prepare Cables and Remove Jacket

    DANGER: Ensure all apparatus is de-energized before beginning installation. Train the cables into their final position, square cut them, leaving approximately 5mm between cables. Store the heat shrink tubing on either cable. Remove the jackets of both cables to the specified dimensions (e.g., 405mm for Size A). Carefully remove the cable metallic tape screen for the specified distance and secure the ends with PVC tape, ensuring no overlap onto the non-metallic screen.

  2. Remove Non-Metallic Screen and Bevel Insulation

    WARNING: DO NOT NICK, CUT, OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the specified point. Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 45mm for Size A) from the end of both cables, but DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for Size A) to locate the splice later.

  3. Temporarily Store Joint Housing

    Apply one layer (half-lapped) of PVC tape over the metallic screen, beginning at the jacket and extending 10mm beyond the end of the metallic screen. Install a different color PVC tape marker on Cable 1 to dimension 'B'. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. Store the housing onto Cable 1 up to the jacket. WARNING: DO NOT STORE THE SPLICE HOUSING ON EXPOSED METALLIC TAPE SHIELD. Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing.

  4. Remove Cable Insulation

    Remove the cable insulation from both cables to dimension 'E' (e.g., 45mm for Size A). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  5. Install and Crimp Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP at this stage. Check the distance between insulations; if it exceeds the 'Before' dimension in the provided table, DO NOT PROCEED and redo the assembly. Crimp the conductor splice according to the crimp chart. Remove any sharp protrusions or burrs, and ensure all metal chips or filings are removed from the splice joint assembly area. Wipe off any excess inhibitor. Check the distance between cable insulations again; if it exceeds the 'After' dimension, DO NOT PROCEED and redo the assembly.

  6. Clean and Lubricate Core Surfaces

    WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces using the supplied lubricant, wiping towards the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen.

  7. Install Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance 'X' between the joint housing and the PVC tape marker on each side, ensuring these distances are equal. Remove the PVC tape applied in Step C to expose 25mm of the copper tape shield.

  8. Restore Cable Screen

    Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.

  9. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds; WARNING: DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tubing from Cable 1 over the center of the assembly and shrink it, starting at the center and working towards the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.