ABB - Installation Products 15PCJ1F2200 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Copper Conductor. Conductor Size AWG Stranded #4/Solid #3.

ABB Installation Products 15PCJ1F2200 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786459780


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB 15PCJ1F2200: 15kV power cable joint for industrial applications. Style 1, single-piece housing for straightforward installation. Accommodates cable insulation diameters: 0.640" to 0.820". Copper conductor. Suitable for stranded AWG #4 or solid AWG #3 copper conductors. Elastimold® 15PCJ1 Power Cable Joints are permanent, fully shielded, fully submersible, straight splices. For 15kV use rated per IEEE Standard 404. Withstands 500 lbs pull. Designed to accept cable insulation diameters of .640’’ to 2.120’’. Cable entrance provides electrical and water seal integrity. Operates on UD cable with concentric neutral and extruded insulation shielding, fabric tape shielded, or lead-jacketed cables (with proper Elastimold® cable shield adapter or grounding device). Ratings: 110kV BIL – Impulse Withstand, 35kV AC – Withstand, 13kV AC – Corona Extinction @ 3pC sensitivity. Continuous and short-time current ratings equal to cable rating up to 35kA. Shield design meets IEEE Standard 592. Cyclic aging: 30 days at 26.1kV AC continuous, 8 hours/day load current, 130°F conductor temperature. Connectors meet ANSI C119.4 Class A and Class 3. Features: molded conductive shield for deadfront construction, fully shielded, fully submersible molded rubber housing, molded conductive insert prevents entrapped air. Grounding eye for ground wire connection. Cable entrance engages insulation shielding, eliminating taping.
  • 15kV Voltage Class Power Cable Joint
  • Accommodates 0.640" to 0.820" Cable Insulation Diameter
  • Copper Conductor for Stranded AWG #4 or Solid AWG #3
  • Fully Shielded, Fully Submersible Molded Rubber Housing
  • Meets IEEE Standard 404 and ANSI C119.4 Class A & 3 Ratings

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#4 STR AWG , #3 SOL AWG , #2 STR AWG , #1 SOL AWG
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ1F2200
Size
14-3/8 inch long
Size
0.640 inch to 0.820 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8000 L
Package Weight (Metric)
0.3630 kg
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ1F1220-1210

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1. luminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ1F1220

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1F1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1-J2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4

69TCJS44

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

69TCJS44B54P45SLNNB

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1RA46PNNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

Frequently Asked Questions

What is the insulation diameter range for this cable joint?

The ABB 15PCJ1F2200 is designed to accommodate cable insulation diameters ranging from 0.640 inches to 0.820 inches.

What type of conductor is used in this ABB cable joint?

This ABB 15kV power cable joint utilizes a copper conductor for excellent conductivity and durability.

What conductor sizes are compatible with the 15PCJ1F2200?

The 15PCJ1F2200 is compatible with AWG #4 stranded or AWG #3 solid copper conductors.

What is the voltage rating of this ABB cable joint?

The ABB 15PCJ1F2200 is rated for 15kV (kilovolts) for medium voltage power applications.

What style of housing does the 15PCJ1F2200 feature?

The 15PCJ1F2200 features a single-piece housing for straightforward installation.

How to Install the 15PCJ1F2200 Single Core Joint

This guide provides step-by-step instructions for the permanent installation of the 15PCJ1F2200 single core, fully screened, submersible joint for extruded solid dielectric cables. It covers cable preparation, connector installation, and joint housing assembly.

Estimated time: 1h 30m

Tools needed:

Wire brush, Cleaning solvent, Clean cloth, Crimping tool, Soldering equipment (optional), Heat gun, Cable stripping tools, Knife

Supplies needed:

PVC tape, Copper compression connector (if copper conductor), Aluminum compression connector (if aluminum conductor), Conductor splice, Lubricant, Flat copper braid, Constant force spring (optional), Mastic tape, Heat shrink

  1. Prepare Cables by Removing Jacket and Metallic Shield

    DANGER: All apparatus must be de-energized during installation or removal of part(s). Do not touch or move energized products in the work area. Train the cables into their final position and square cut, leaving approximately 5mm between cables. Store the heat shrink on either cable. Remove the jackets of both cables to the dimensions specified in the documentation (e.g., 405mm for Size 1F-1G). Carefully remove the cable metallic tape screen for the specified distance (e.g., 125mm for Size 1F-1G) and secure the ends with PVC tape. Keep the PVC tape on the copper tape; do not overlap onto the non-metallic screen.

  2. Remove Non-Metallic Screen and Bevel Cable 1

    WARNING: DO NOT NICK, CUT OR DAMAGE THE INSULATION SURFACE OR CONDUCTOR STRANDS. Carefully remove the cable non-metallic screen from both cables to the point specified (e.g., 45mm for Size 1F-1G). Bevel the edge of Cable 1. Cut the insulation to the conductor to dimension 'E' (e.g., 150mm for Size 1F-1G) from the end of both cables; DO NOT remove the insulation. Install a PVC tape marker on Cable 2 to dimension 'B' (e.g., 155mm for Size 1F-1G) to locate the splice later.

  3. Temporarily Store Joint Housing and Prepare Cable 1

    Beginning at the jacket and proceeding 10mm beyond the end of the metallic screen, apply one layer (half lapped) of PVC tape over the metallic screen on Cable 1. Install a different color PVC tape marker on Cable 1 to dimension 'B' (e.g., 155mm for Size 1F-1G) to locate the splice later. Lubricate both cable entrances of the splice housing. Clean and lubricate the insulation, cable non-metallic screen, and PVC taped portion of the cable metallic tape screen on Cable 1. WARNING: THE FORWARD EDGE AND ANY OTHER SHARP EDGES OF THE METALLIC SCREEN MUST BE COVERED WITH PVC TAPE TO PREVENT DAMAGE TO THE JOINT HOUSING WHEN STORING IT ON PVC TAPED PORTION OF THE CABLE. Store the housing onto Cable 1 up to the jacket. DO NOT STORE SPLICE HOUSING ON EXPOSED METALLIC TAPE SHIELD.

  4. Remove Cable Insulation

    Remove cable insulation from both cables to dimension 'E' (e.g., 150mm for Size 1F-1G). WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.

  5. Install and Crimp the Conductor Splice

    Wire brush the exposed conductors of both cables. Immediately insert the conductors into the conductor splice, ensuring both conductors are fully seated. DO NOT CRIMP yet. Check the distance between insulations. If it exceeds the 'Before' dimension (e.g., 102mm for Size 1F-1G), DO NOT PROCEED; review the instructions and redo the assembly. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs. Metal chips or filings must be removed from the splice joint assembly area prior to sliding the joint. Wipe off all excess inhibitor. Check the distance between cable insulations again. If it exceeds the 'After' dimension (e.g., 108mm for Size 1F-1G), DO NOT PROCEED; review the instructions and redo the assembly.

  6. Clean and Lubricate Core Surfaces

    WARNING: REMOVE ALL CONTAMINANTS FROM THE SURFACE OF THE INSULATION. Clean the conductor, connector, and Cable 2 insulation surfaces with cleaning solvent and a clean cloth. Always wipe towards the screen end. Lubricate cable insulation surfaces using the supplied lubricant. Always wipe toward the screen end to provide a build-up or ramp of lubricant at the edge of the non-metallic screen.

  7. Install the Joint Housing

    Slide the joint housing over the crimp connector into its final position. Measure the distance between the joint housing and the PVC tape marker. The distance 'X' should be equal on each side of the joint housing. Remove the PVC tape applied in Step C to expose 25mm of copper tape.

  8. Restore the Screen

    Wrap flat copper braid around each joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by soldering or by using a constant force spring.

  9. Restore the Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm. Heat both sanded areas for approximately 15 seconds. DO NOT BURN CABLES. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.