Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1F1270 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

ABB Installation Products 15PCJ1F1270 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786820740


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 15kV Power Cable Joint (SKU: 15PCJ1F1270) provides a reliable, single-piece housing solution for terminating and joining 15kV power cables with aluminum conductors. Designed for cables with insulation diameters between 0.640 inch and 0.820 inch, this joint accommodates conductor sizes ranging from 4/0 AWG stranded to 250 AWG solid aluminum. The single-piece housing simplifies installation by eliminating multiple components, reducing assembly time, and minimizing the risk of misalignment or contamination. This joint is rated for 15kV systems, making it suitable for medium-voltage power distribution in industrial, commercial, and utility applications. The aluminum conductor compatibility aligns with common utility and industrial cable standards, ensuring broad compatibility with existing infrastructure. Installation requires standard tools and follows ABB’s proven jointing procedures for medium-voltage systems. The product is part of ABB’s Installation Products catalog, a trusted brand in electrical infrastructure solutions.
  • Rated for 15kV systems with aluminum conductor compatibility
  • Single-piece housing for simplified installation and reduced assembly time
  • Accommodates cable insulation diameters from 0.640" to 0.820"
  • Supports conductor sizes from 4/0 AWG stranded to 250 AWG solid
  • Part of ABB Installation Products catalog for medium-voltage applications

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
4/0 STR AWG , 250 kcmil
Connection
Compression
Connection Type
Single-piece housing
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ1F1270
Size
14-3/8 inch long
Size
0.640-0.820 inch insulation diameter, 4/0-250 AWG conductor
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1H2270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1-J2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4

69TCJS44

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4
69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

69TCJS44B54P45SLNNB

69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4 - Bore Diameter 2.250 inch, Insulation Range 2.565-2.948 inch, Connector Type - Copper/No Connector Required, Conductor Code 54P - 1.648-1.746 inch Diameter, Heatsink Size 4 - 2.500 inch Outside Diameter, Heatsink Bore Diameter S - 1.750 inch, Type Shield L - Lead and Neutral Wire, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1RA46PNNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum/no connector required, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size - N - not required, Heatsink Bore - N - not required. Type Shield - N - not required, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1R242PNLNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Copper, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - L - Lead and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1R140PVBNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size R Bore Diameter at Jacket/Insulation Transition 1.930. Connector Type - Aluminum, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - V - 2.046 inch Diameter. Type Shield - B - Copper Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q233PRCBNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 33P - Conductor Diameter Range - .781-.815 inch (19.84-30.70mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Frequently Asked Questions

What are the two styles of PCJ power cable joints?

Style 1 has a single-piece housing for straight splicing of similar cables. Style 2 has a universal housing with separate cable adapters for transition splicing.

What are the suitable installation environments for PCJ joints?

PCJ power cable joints can be installed in direct-burial, underground vault, and overhead applications, providing a permanent, fully shielded, and fully submersible splice.

What are the main uses of PCJ power cable joints?

PCJ power cable joints are used for straight splicing of two similar cables or transition splicing of different cable sizes up to 1250 kcmil.

What voltage classes are PCJ power cable joints available in?

PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor types and sizes are compatible with PCJ joints?

PCJ power cable joints are compatible with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What pull force can the pin-and-socket interlock withstand?

The pin-and-socket interlock in PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What connector type is needed for copper-to-copper splices?

An all-copper compression connector is required for copper-to-copper connections. The standard kit includes an aluminum connector for aluminum-to-aluminum or aluminum-to-copper.

What is the continuous and short-time current rating?

The continuous current rating is equal to that of the cable rating. The short-time current rating is equal to the cable rating up to 35 kA.

What is the AC withstand voltage for a 15 kV class joint?

For a 15 kV class PCJ power cable joint, the AC withstand at 60 Hz for 1 minute is 35 kV.

How to Install a Single Core Cable Joint (15PCJ1F1270)

This guide provides step-by-step instructions for the permanent installation of a single core, fully screened, submersible cable joint for extruded solid dielectric cables. It covers cable preparation, connector installation, and joint housing assembly.

Estimated time: 2h 30m

Tools needed:

Wire strippers, Wire brush, Crimping tool, Cleaning solvent, Clean cloth, Soldering iron (optional), Heat gun, Sandpaper

Supplies needed:

Joint housing, PVC tape, Compression connector (copper or aluminum), Lubricant (supplied), Mastic tape, Flat copper braid, Constant force spring (optional), Heat shrink tube

  1. Prepare Cables and Remove Jacket

    Ensure all apparatus is de-energized. Train cables into final position, square cut them leaving approximately 5mm between ends. Store the heat shrink tube onto one cable. Remove the outer jacket from both cables to the specified dimension 'A'. Carefully remove the cable metallic tape screen for distance 'B' and secure ends with PVC tape, ensuring it's only on the copper tape and does not overlap the non-metallic screen.

  2. Remove Non-Metallic Screen and Bevel Insulation

    Warning: Do not nick, cut, or damage the insulation surface or conductor strands. Carefully remove the cable non-metallic screen from both cables to the specified point 'D'. Bevel the edge of the insulation on Cable 1. Cut the insulation to the conductor to dimension 'E' from the end of both cables, but do not remove this insulation yet. Install a PVC tape marker on Cable 2 at dimension 'B' from the jacket edge to locate the splice later.

  3. Store Joint Housing Temporarily

    Apply one layer (half lapped) of PVC tape over the metallic screen of Cable 1, starting at the jacket and extending 10mm beyond the metallic screen end. Warning: Cover any sharp edges of the metallic screen with PVC tape to prevent damage to the joint housing. Install a different color PVC tape marker on Cable 1 at dimension 'B'. Lubricate both cable entrances of the joint housing. Clean and lubricate insulation, non-metallic screen, and PVC-taped metallic screen on Cable 1. Store the housing onto Cable 1 up to the jacket; do not store on exposed metallic tape shield.

  4. Install Conductor Splice

    Warning: Do not cut or nick the cable insulation or conductor. Remove the previously cut insulation from both cables to dimension 'E'. Wire brush the exposed conductors of both cables. Immediately insert both conductors fully into the conductor splice (compression connector); do not crimp yet. Verify the distance between the cable insulations against the 'Before Crimping' specification. Crimp the conductor splice according to the provided crimp chart. Remove any sharp protrusions or burrs and metal chips. Wipe off any excess inhibitor. Re-check the insulation distance against the 'After Crimping' specification.

  5. Clean and Lubricate Core

    Warning: Remove all contaminants from the surface of the insulation. Clean the conductor, connector, and Cable 2 insulation surfaces using cleaning solvent and a clean cloth, always wiping towards the screen end. Lubricate the cable insulation surfaces using the supplied lubricant, wiping toward the screen end to create a build-up or ramp of lubricant at the edge of the non-metallic screen.

  6. Position Joint Housing

    Slide the joint housing over the crimped connector into its final position, centering it over the splice. Measure the distance 'X' between the joint housing and the PVC tape marker on both sides; ensure these distances are equal. Remove the PVC tape applied in Step 3 from Cable 1 to expose 25mm of the copper tape shield.

  7. Restore Cable Screen

    Wrap flat copper braid around each side of the joint housing, continuing the ends over the metallic tape screen for 20mm on each side. Attach each end of the copper braid to the metallic tape screen by either soldering or using a constant force spring.

  8. Restore Outer Jacket

    Lightly sand the outer surface of the jacket of both cables for a distance of 130mm on each side of the joint. Heat both sanded areas for approximately 15 seconds. Warning: Do not burn the cables. Wrap two layers of mastic tape at the edge of the jacket on both cables. Position the heat shrink tube (stored in Step 1) over the center of the assembly. Shrink the heat shrink tube, starting at the center and working outwards towards the ends, ensuring a tight seal.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.