Contact for Pricing
Overview
- 200 Amp current rating
- 15/25kV voltage class
- Deadbreak elbow cable entrance insulating plug
- Accommodates cable insulation diameter: 0.575" to 0.685"
- 9.25 inches long, constructed of plastic
Specifications
Application | Holds Elbow in Place and Seals Cable Entrances |
Connection | Threaded |
Material | Plastic |
Size | Cable Insulation Diameter 0.575 inch to 0.685 inch |
Special Features | Non-Electrical. Fake Probe |
Type | Plastic Insulating Plug |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

K675TBC
15/25kV, 900 Amp, Deadbreak Bushing for In-Air Applications (Pad-Mounted or Vault-Type or Submersible Transformers or Switchgear). One Factory installed 5/8-11 UNC-2A Stud included, other Stud must be Purchased Separately. Overall Length 13.75 inch, Diameter 4.50 inch. Molded Epoxy with Stainless Steel Flange. Boot and Collar.
K655VSL2-MAC04
15/25kV, 600 Amps, 2-Way Vault-Stretcher with Shear Bolts. Cable Insulation Diameter range 1.37-1.63 inch (34.8-41.4mm). Connector Sizing AC04 - 750-1250 kcmil Stranded, Compressed, Solid or Compact. Kit Includes (1) Vault Stretcher Housing, (2) Aluminum Shear Bolts, (2) Cable Adapters and (2) Insulated Plugs with Caps and (1) Stud.
151-GP
15/25kV 200 Amp, Deadbreak Grounding Plug, Bails are required, but not included, order separately.
1601DLA
15kV, 200 Amp, DeadBreak to LoadBreak Bushing Adapter, Red. Includes hex-broach for Torque installation, Peroxide-cured insulation and jacket, Provision for ground wire connection, All copper current path. Red PBT interface shield reduces sticking and provides seating indicator.Frequently Asked Questions
What is the purpose of the Elastimold 10EP insulating plug?
The 10EP insulating plug is designed to electrically insulate and water seal the cable entrances of Elastimold 200 Amp elbow connectors. It also provides a sound dead-end cable entrance.
What components are included in the 10EP kit?
Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.
How is the normal function of the elbow connector restored?
The normal function of the elbow connector is restored by simply removing the 10EP and replacing it with a properly prepared cable.
What cable insulation diameters are compatible with the 10EP-FA?
The 10EP-FA is compatible with cable insulation diameters ranging from 0.575 inches minimum to 0.685 inches maximum.
Which Elastimold elbow cable entrance sizes are available for the 10EP plug?
The 10EP plug is available for Elastimold elbow cable entrance sizes EB, EF, FA, FAB, FB, FG, GA, GAB, and GB.
How do I order the 10EP elbow cable entrance insulating plug?
To order, specify the number 10EP-W.
What is the purpose of the Elastimold 10EP insulating plug?
The 10EP insulating plug is designed to electrically insulate and water seal the cable entrances of Elastimold 200 Amp elbow connectors. It also provides a sound dead-end cable entrance.
What components are included in the 10EP kit?
Each kit contains one Insulated Plug 10EP, one Crimp Chart IS-0169, and one Lubricant 82-08.
How is the normal function of the elbow connector restored?
The normal function of the elbow connector is restored by simply removing the 10EP and replacing it with a properly prepared cable.
What cable insulation diameters are compatible with the 10EP-FA?
The 10EP-FA is compatible with cable insulation diameters ranging from 0.575 inches minimum to 0.685 inches maximum.
How to Install the 10EP Elbow Cable Entrance Insulating Plug
This guide provides step-by-step instructions for safely installing the 10EP Elbow Cable Entrance Insulating Plug onto an Elastimold 200amp Deadbreak or Loadbreak elbow, including initial setup and voltage testing. Ensure all apparatus are de-energized before beginning installation.
Estimated time: 15m
Tools needed:
Pliers, Hotstick, Suitable sensing device
Supplies needed:
10EP Elbow Cable Entrance Insulating Plug, Lubricant, Male contact, No. 14 AWG (2.5mm2) copper wire, Silicone grease
- Lubricate the Insulating Plug
Lightly lubricate the surface of the insulating plug with the supplied or ELASTIMOLD approved lubricant for approximately 4-1/2 inches from the second chamfered step. DO NOT SUBSTITUTE other lubricants, as they may be harmful to the product or its mating parts.
- Position and Insert the Insulating Plug
Position the insulating plug so its flat contact area faces the receptacle end of the elbow connector. Slide the 10EP into the elbow connector until it cannot advance any further. Look into the receptacle end of the elbow to verify the threaded hole in the 10EP is properly positioned to accept the male contact. If not, use pliers on the exposed end of the 10EP to turn it into position.
- Install and Tighten the Male Contact
Remove the protective cap from the threads of the male contact. Insert the threaded end of the male contact into the threaded hole of the insulating plug located in the receptacle end of the elbow. Hand tighten this contact. SNUG TIGHTEN ONLY to avoid stripping threads; do not tighten until a wrench bends as indicated in the elbow connector instructions.
- Complete Elbow Assembly and Grounding
Lightly lubricate both the bushing and elbow connector mating surfaces. Complete the elbow assembly as indicated in the specific instructions for the elbow. Ground the elbow by connecting a piece of wire equivalent to No. 14 AWG (2.5mm2) copper from the apparatus ground to the elbow grounding eye.
- Remove the Test Point Cap
Using a hotstick, remove the test point cap. When removing the cap, PEEL IT OFF AT AN ANGLE rather than pulling directly in line with the test point assembly.
- Perform Voltage Test
WARNING: The voltage test point is a capacitance device and is NOT DIRECTLY CONNECTED TO THE CONDUCTOR. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device, made for use with separable connectors manufactured with capacitive test points, to determine if the cable is energized. Contamination, moisture, dirt, or using the wrong measuring equipment can provide a false “no voltage” indication. To prevent serious or fatal injury, treat the elbow as energized until the “no voltage” test point indication is confirmed by other means.
- Replace the Test Point Cap
After voltage detection has been made, clean and lubricate the inside surface of the cap with silicone grease and replace it securely on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.