All Categories

Electrical Systems and Lighting and Components and Accessories and Supplies

Electrical Equipment, Components, and Supplies

Electrical Lugs Plugs And Connectors

Subcategories

    Automatic Wire Or Cable Connector

    Backshell connectors

    Battery Terminal

    Cable Gland Connector

    Cable Joint

    Cable Or Wire Lug

    Circular Connectors

    Coaxial Connectors

    Connecting Leads or Wires

    Connector And Cable Seal

    Crab Joint

    Electrical Connector Assembly

    Electrical Extension Cable

    Electrical Metallic Tubing Emt Connectors

    Electrical Metallic Tubing Emt Elbow

    Electrical plug/receptacle adapter

    Electrical Plugs

    Electrical Receptacles

    Electrical Sleeves

    Electrical Taps

    Electrical Terminals

    Electrical Underground Bus Connector

    Electrodes

    Electronic Connector Caps

    Flex Connectors

    Flexible Braid

    Heavy Duty Connector Hood & Housing

    Heavy Duty Connector Insert & Contact

    Input Output Connector Cover

    Jack for Plug

    Jumper Bar

    Liquid Tight Connectors

    Locking Plug

    Mechanical Connector Lug and Cap

    Mechanical Connectors

    Panel Interface Connector

    Power Distribution Blocks

    Printed Circuit Board Pcb Press Fit Header Connector

    Rj Jack And Module

    Tap Off

    Telecommunication Connector

    Terminal Block Accessories

    Terminal Block Covers

    Terminal Block Markers and Marking Accessories

    Terminal Block Separator

    Terminal Blocks

    Terminal Strips

    Twist On Wire Connector

    Wire Connectors

    Wire Or Cable Compression Connector

    Wire Or Cable Compression Reducer

    Wire Or Cable Compression Splice

    Wire Terminal Connector Kit

    Wire Terminal Disconnect

    Wiring Taps

Showing 2113-2124 of 2,552 results

ABB - Installation Products K151SP-B0270 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
ABB - Installation Products · ABB

K151SP-B0270


200 Amp, 15/25kV, Deadbreak Elbow, Straight Plug, Bails are required but not included, order separately. Cable Insulation Diameter 0.635 inch to 0.905 inch. Includes an aluminum compression lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Contact for Pricing

ABB - Installation Products 274ELR-88110-5270 - 200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
ABB - Installation Products · ABB

274ELR-88110-5270


200 Amp, 25kV, Loadbreak Repair Elbow Connector with Test Point, Repair Elbow has extended length contact and elbow housing resulting in a net gain of 3-1/4 inches in length. Includes 02509X long Bi-Metal Contact. Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

Contact for Pricing

ABB - Installation Products K151SR-C0260 - 200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.
ABB - Installation Products · ABB

K151SR-C0260


200 Amp, 15/25kV, Deadbreak Elbow, Straight Receptacle, Bails are required but not included, order separately. Cable Insulation Diameter 0.805 inch to 1.060 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 3/0 or Solid 4/0 or mmSquared 85.01.

Contact for Pricing

ABB - Installation Products 376LR-L-5270-S - 200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
ABB - Installation Products · ABB

376LR-L-5270-S


200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

Contact for Pricing

ABB - Installation Products 167RLR-G5230-S - 200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.
ABB - Installation Products · ABB

167RLR-G5230-S


200 Amp, 15kV, Loadbreak Replacement Elbow Connector without Test Point, Cable Insulation Diameter 0.760 inch to 0.950 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact. 200ECS Jacket Seal Included.

Contact for Pricing

ABB - Installation Products 274FLR3-B0250 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
ABB - Installation Products · ABB

274FLR3-B0250


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

Contact for Pricing

ABB - Installation Products 274FLR3-B0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
ABB - Installation Products · ABB

274FLR3-B0220


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

Contact for Pricing

ABB - Installation Products 274FLR1-C0270 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
ABB - Installation Products · ABB

274FLR1-C0270


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

Contact for Pricing

ABB - Installation Products 274FLR1-B0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
ABB - Installation Products · ABB

274FLR1-B0220


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

Contact for Pricing

ABB - Installation Products 274FLR1-B5240 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.
ABB - Installation Products · ABB

274FLR1-B5240


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact.

Contact for Pricing

ABB - Installation Products 274FLR1-C0230 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact
ABB - Installation Products · ABB

274FLR1-C0230


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact

Contact for Pricing

ABB - Installation Products 168FLR3-C5260 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.
ABB - Installation Products · ABB

168FLR3-C5260


Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

Contact for Pricing