ABB - Installation Products 274FLR1-C0230 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid Compact

ABB Installation Products 274FLR1-C0230 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 783786527755


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-C0230 is a molded current limiting fuse housing designed for medium-voltage applications up to 15.5kV. This compact unit is engineered to accommodate cable insulation diameters ranging from 0.805 inches (20mm) to 1.060 inches (27mm), making it suitable for a variety of industrial and utility power distribution systems. It supports aluminum conductors, specifically 1 AWG stranded compressed or 1/0 AWG solid compact configurations. Key features include two capacitive test ports, facilitating safe voltage verification without requiring system de-energization, which enhances maintenance efficiency and safety. Applications include use in substations, switchgear, and distribution panels requiring reliable overcurrent protection for transformers, motors, and feeders within medium-voltage circuits. The molded construction provides environmental resistance and mechanical durability for indoor or outdoor installations where space is a consideration. SKU: 274FLR1-C0230.
  • Molded current limiting fuse housing for 15.5kV nominal fuse voltage.
  • Accommodates cable insulation diameters from 0.805" (20mm) to 1.060" (27mm).
  • Supports aluminum conductors: 1 AWG stranded compressed or 1/0 AWG solid compact.
  • Equipped with two capacitive test ports for safe voltage verification.

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#1 STR/COMPR AWG , 1/0 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.

K656YSR-H0230

600 Amp, 15/25kV, Deadbreak, Straight Receptacle with Test Point, Cable Insulation Diameter .850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1 or Compacted Solid 1/0.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR1-D0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

274AFLR1-D0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR1-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3B0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

168FLR3A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR1-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

168FLR3-C5260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

Frequently Asked Questions

Are sealing and grounding kits required for installation?

For safety purposes, a sealing and grounding kit is highly recommended with the loadbreak elbow. Specific kits are available for different cable types.

What is the purpose of the built-in test points?

The built-in voltage test points provide quick and convenient indication of a blown fuse.

How is fuse replacement handled?

The 274FLR features a split center section for easy fuse replacement.

Does the 274FLR have a fuse included?

No, the fuse for the 274FLR is ordered separately.

Is the 274FLR submersible?

Yes, the 274FLR is fully sealed and submersible when used with ECS series sealing kits.

What is the impulse withstand rating (BIL)?

The impulse withstand rating (BIL) is 140kV.

What is the current rating range for the fuse?

The current rating for the fuse is 6-20 Amps.

What is the symmetrical interrupting capability?

The symmetrical interrupting capability of the 274FLR is 50,000 Amps.

What is the voltage class for this product?

The product is designed for 25/28kV Voltage Class, with a 16.2kV nominal fuse voltage (phase to ground).

What is the primary application of the 274FLR?

The 274FLR combines full-range current-limiting fusing with 25kV/28kV hot stick operable, loadbreak elbow switching. It protects light duty underground distribution systems including sub-loops and radial taps.

How to Install the 168FLR or 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and initial setup of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connections. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 2h

Tools needed:

Probe Wrench, Allen Wrench (torque limiting, supplied), Wire brush, Crimp tool (refer to compression lug instructions), Hotstick (for post-installation operation)

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant (supplied), 200ECS Cold Shrink Cable Seal (optional), Copper wire (No. 14 AWG / 2.5mm or equivalent), HV insulated cap(s) or connector(s) (if applicable)

  1. Perform Pre-Installation Checks and Safety Procedures

    DANGER: Ensure all apparatus are de-energized during installation. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Check the contents of the package to ensure all components are complete and undamaged. Verify proper fit with the cable and/or mating products. Check threads by threading the probe into the compression lug; replace damaged components if resistance is encountered. Read all instructions thoroughly before starting. Have all required tools at hand and maintain cleanliness. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.

  2. Train and Prepare the Cable

    Using the bushing centerline as a reference, cut excess cable off 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable if used. Remove the jacket from the excess cable length remaining AND the distance of “A” (fuse body length: 11-1/2 inches for FLR-1, 15-3/4 inches for FLR-3) plus 7-3/8 inches from the bushing centerline. If a Cable Seal kit is used, follow its instructions; otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of “A” from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate.

  3. Prepare the Cable End

    Cut 1-1/8 inches from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp (refer to the crimp chart provided with the lug). Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Lubricate and Insert Cable into Elbow Half

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. DO NOT SUBSTITUTE LUBRICANT. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface “A”. This positioning allows the fuse to be tightened before bottoming on the rubber.

  5. Install and Hand Tighten the Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over-torqued. After hand tightening, pull the housing up against the bottom of the tightened fuse.

  6. Assemble and Lock the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  7. Assemble Elbow Halves and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; you may need to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread. To tighten, use the special torque-limiting allen wrench supplied: insert the short end into the hole in the probe and tighten until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it, but DO NOT OVERTIGHTEN.

  8. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  9. Lubricate and Prepare for Final Connection

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. The elbow is now ready for connection to the bushing plug following the operating instructions, but DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.