Authorized ABB Distributor (Installation Products)
ABB - Installation Products 274FLR1-B0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

ABB Installation Products 274FLR1-B0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…

UPC: 783786516810


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 274FLR1-B0220 molded current limiting fuse housing is a compact, high-voltage solution engineered for 15.5kV nominal fuse voltage ratings in medium-voltage distribution systems. This small housing accommodates cable insulation diameters between 0.635 inch (16mm) and 0.905 inch (23mm), supporting 2 AWG stranded compressed aluminum conductors or 1 AWG solid compact conductors. The molded design provides mechanical strength and environmental protection, reducing contamination or damage risks in harsh operating conditions. Two capacitive test ports enable safe diagnostic testing without system interruption, ensuring operational reliability. The housing integrates seamlessly into pad-mounted transformers, switchgear, and underground distribution systems, optimizing space utilization in tight installations. With an insulation system rated at 105°C and a temperature rise of 55°C, the 274FLR1-B0220 meets stringent performance standards for industrial and utility applications. Its aluminum construction ensures long-term durability with minimal maintenance requirements. Compatible with ABB’s current limiting fuse systems, this fuse housing supports primary fuse holders (2x) and secondary fuse clips (1x) for flexible configuration. The compact form factor and durable molded construction make it ideal for medium-voltage protection in confined spaces where reliability and safety are critical.
  • Nominal fuse voltage rating: 15.5 kV
  • Cable insulation diameter range: 0.635–0.905 inch (16–23 mm)
  • Supports 2 AWG stranded compressed aluminum or 1 AWG solid compact conductors
  • Two capacitive test ports for safe diagnostic testing without system interruption
  • Insulation system rated at 105°C with 55°C temperature rise

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
16.87 in
Length
428.498 mm
Material
EPDM-Rubber
Material
Molded, Aluminum
Series
274FLR1
Size
Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Voltage Rating
15.5 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-C0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

274AFLR3-B5230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact

274FLR1-D0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

274AFLR1-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
25kv Fuse Elbow Size 3 Housing, No Sealing Kit, 25 kV Fused Elbow Large Housing with Insulation Diameter Range of .805 inch-1.060 inch and Bi-Metal Connector for #1 Stranded/Compressed Conductor or 1/0 Solid/Compact Conductor.

274AFLR3-C5230

25kv Fuse Elbow Size 3 Housing, No Sealing Kit, 25 kV Fused Elbow Large Housing with Insulation Diameter Range of .805 inch-1.060 inch and Bi-Metal Connector for #1 Stranded/Compressed Conductor or 1/0 Solid/Compact Conductor.

Frequently Asked Questions

What is the nominal fuse voltage?

The nominal fuse voltage for the 25/28kV voltage class is 16.2kV (Phase to Ground).

What is the impulse withstand rating?

The impulse withstand (BIL) rating is 140kV (1.2 x 50 microsecond wave).

What shield adapter is used for Unishield cables?

For Unishield Cables, the shield adapter part number is 10TL-W, where "W" is determined by the cable's insulation diameter, or add suffix "-TL".

What sealing kit is used for concentric neutral cables?

For Jacketed Concentric Neutral Cables, the sealing kit part number is 200ECS or add suffix "-S" for cables with nominal O.D. within 0.80 in - 1.50 in.

Which housing size is for 6-20A 15.5kV fuses?

Housing H Code 1 is for 6-20A 15.5kV fuses, as well as 3-45A 8.3kV fuses.

What is the recommended safety accessory?

For safety purposes, a sealing & grounding kit with the loadbreak elbow is highly recommended.

Is the fuse included with the elbow connector?

No, the fuse is ordered separately and is not included with the elbow connector kit.

What standards does this product meet?

The product meets IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47, latest revisions.

Is the fused elbow submersible?

Yes, the Elastimold Fused Elbow is fully sealed and submersible when used with ECS series sealing kits.

What is the interrupting capability of the product?

The product has a symmetrical interrupting capability of 50,000 Amp, featuring full-range current-limiting fusing.

How to Install the 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connection.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Probe Wrench, Allen Wrench

Supplies needed:

274FLR Cable Half Housing, 274FLR Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, No. 14 AWG Copper Wire, Optional 200ECS Cold Shrink Cable Seal

  1. Prepare the Cable for Termination

    DANGER: Ensure all apparatus is de-energized before beginning installation to prevent serious or fatal injury. This product must be installed by competent personnel trained in high voltage electrical equipment safety practices. Cut excess cable, then remove the cable jacket for a length of 11-1/2" + 7-3/8" from the bushing centerline. Unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 11-1/2" from the bushing centerline, leaving 7-3/8" minimum for termination.

  2. Prepare Cable End and Install Compression Lug

    Cut 1-1/8" from the cable end, taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Crimp the unthreaded end of the compression lug to the conductor, referring to the crimp chart for your lug and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the outside of the lug and cable.

  3. Prepare Insulation and Lubricate Cable Half

    Remove the insulation shield 5-1/2" from the end of the lug and bevel the insulation end by 1/8" maximum. Thoroughly clean the insulation to remove all traces of conductive residue. Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface "A".

  4. Install Fuse and Probe Connector

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand tighten it into the cable connector. CAUTION: The fuse stud will fracture if over torqued. Pull the housing up against the bottom of the tightened fuse. Assemble the probe connector to the fuse terminal, rotating it so the flats are perpendicular to the bushing. Lock the probe connector in position and tighten the setscrews using the special torque-limiting allen wrench supplied. Rotate the cable half so the test point is perpendicular to the flats on the probe connector.

  5. Assemble Elbow Halves and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring the cuff of the cable half overlaps the elbow half by 3/4". Verify the probe connector faces the opening of the fused elbow half and the two test points are in line. Insert the probe into the probe connector, pushing on the cable if necessary to align it with the fuse. Hand start the threads, then tighten using the special torque-limiting allen wrench supplied until it bends and remains bent. Position the hose clamp as shown in the diagram and tighten it, but do not overtighten.

  6. Connect Concentric Neutral Wires

    Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through each grounding eye on the elbow housing and cable housings, twisting tightly without damaging the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires together, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  7. Connect Elbow to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Securely fasten a hotstick to the loadbreak connector pulling eye. Place the elbow connector receptacle area over the bushing plug, inserting the elbow male contact until the first slight resistance is felt (contacts are approximately 2" apart). Immediately push the elbow home with a fast, firm, straight motion to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.