Panduit E48E21LTAA - TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

Panduit E48E21LTAA TAA EL2P MS PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

UPC: 613056916050


Documents & Media
BrochureTechnical BulletinTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit TAA EL2P MS PDU (SKU: E48E21LTAA) is a high-density vertical power distribution unit designed for critical IT and data center applications. This 30 Amp unit delivers 8.6 kVA of rated power with a derated input current of 24A, ensuring safe operation under load. It features a versatile outlet configuration with 24 IEC C13/C15 outlets and an additional 24 IEC C13/C15/C19/C21 outlets, accommodating a wide range of server, networking, and storage equipment. The NEMA L21-30P input plug provides a secure 3-phase Wye connection with a 3-meter SJT 10 AWG cord for flexible installation. Its vertical 0U form factor maximizes rack space efficiency while maintaining accessibility. The black RAL 9005 finish integrates seamlessly with standard data center aesthetics. Ideal for dense equipment deployments requiring high outlet density and compatibility with multiple IEC plug types.
  • 30 Amp input with 24A derated operation for safe power delivery
  • 48 IEC outlets: 24x C13/C15 + 24x C13/C15/C19/C21 for versatile equipment compatibility
  • NEMA L21-30P 3-phase Wye input plug with 3m SJT 10 AWG cord
  • Three 20 Amp double-pole breakers for circuit protection
  • Vertical 0U form factor for maximum rack space efficiency

Specifications

Color
Black
Current Rating
30 A
Frequency Rating, Maximum
208 V
Frequency Rating, Minimum
208 V
Material
Metal
Mounting
Vertical
Nema Rating
NEMA L21-30P-3M
Phase
3
Series
TAA EL2P MS PDU
Standard
UL 62368-1, CAN CSA-C22.2 No. 62368-1 EMC: FCC 47 CFR Part 15, Class A, Subpart B. ICES-003 Issue 7
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
70.08 IN x 3 IN x 3 IN
Package Dimensions (L x W x H)
178.0032 cm x 7.62 cm x 7.62 cm
Package Weight (Imperial)
22.4900 L
Package Weight (Metric)
10.2015 kg
This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.

P12B19M

This Panduit G5 Basic PDU features (12) 5-20R outlets. It is a 20 amp, 120 V, single phase PDU with a NEMA 5-20P input plug and a 10 foot (3m) power cord. The PDU is black.
MI 208V 30A 42CX

EN1851

MI 208V 30A 42CX
19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black

1589W8G1BKRR

19-inch Rack Mount Outlet Strip, 20A, 8 Switches & 8 Outlets, 15 ft cord, Black
TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

E48G30LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK

E42G03LTAA

TAA EL2P MSPO PDU, 30/32 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 2P+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MS PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK

E48E20LTAA

TAA EL2P MS PDU, 30/32 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 30A/32A (IP44)-3M, BLACK
TAA EL2P MI PDU, 20/16 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK

E48D23LTAA

TAA EL2P MI PDU, 20/16 AMP, (24)C13/C15, (24)C13/C15/C19/C21, IEC 60309 3P+N+E 6h 20A/16A (IP44)-3M, BLACK
TAA EL2P MI PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

E48D21LTAA

TAA EL2P MI PDU, 30 AMP, (24)C13/C15, (24)C13/C15/C19/C21, NEMA L21-30P-3M, BLACK

Frequently Asked Questions

What is the standard warranty for Panduit PDUs?

Panduit PDUs come with a 3-year standard warranty, which can be extended to 5 years.

What is the maximum operating temperature?

Panduit PDUs are built with premium components to withstand 140°F (60°C) at full load.

Do Panduit PDUs feature hot-swappable controllers?

Yes, Panduit PDUs feature hot-swappable controllers that can be removed without affecting outlet status, ideal for service or repair.

What network connectivity options are available?

PDUs offer single or dual Gigabit Ethernet and serial connectivity. Some models also support Wi-Fi and Bluetooth via CNT06.

What can Panduit PDUs monitor in real-time?

Panduit PDUs provide real-time monitoring of power, environmental conditions, and cabinet security.

Are Panduit PDUs compatible with Cisco systems?

Yes, Panduit's intelligent PDUs are compatible with Cisco Nexus Dashboard software for enhanced energy savings and sustainability insights.

Do Panduit PDUs integrate with DCIM solutions?

Yes, intelligent PDUs offer integration with monitoring software for data management and analytics, with EL2P series having native Cisco Nexus Dashboard and Redfish API integration.

What is the maximum daisy chain capacity?

Daisy chain capacity varies by model, with ES2P supporting 16, G6 supporting 32, and EL2P supporting up to 64 PDUs.

What is the metering accuracy of Panduit PDUs?

Metering accuracy is ± 2% for ES2P and G6 models, and ± 0.5% for EL2P models.

How are vertical PDUs mounted?

Vertical PDUs feature tool-less mounting buttons for quick and secure attachment to rack keyhole slots, simplifying setup.

How to Install and Connect a Panduit EL2P PDU

This guide provides step-by-step instructions for qualified personnel to safely install, ground, and connect a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet. Ensure all safety precautions are followed to prevent electric shock or equipment damage.

Estimated time: 45m

Tools needed:

#2 Phillips screwdriver, 2.5mm hex key Allen wrench, T10 Torx screwdriver

Supplies needed:

Mounting hardware (screws, cage nuts), Ground bonding cable, Power cord (appropriate for PDU input)

  1. Review Safety Information and Prepare for Installation

    Before beginning, thoroughly read all safety information in the PDU manual. Ensure installation is performed by qualified personnel. Verify that the PDU and connected devices are compatible with the line voltage. Confirm the installation environment is indoors, temperature/humidity controlled (0°C to 60°C, 90% max non-condensing), and free of conductive contaminants. Position the PDU to maintain 2-3 inches clearance from cabinet frames/side panels and seal unused rack spaces with blanking panels to ensure proper airflow.

  2. Mount the PDU in the Rack

    For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket. Secure them using a #2 Phillips screwdriver to a torque of 3.0Nm. For horizontal PDUs, install cage nuts at the desired U location. Screw the mounting bracket ears into the RETMA rail surface. For high power horizontal PDUs, install cage nuts on both front and rear rails, then secure mounting bracket ears to both front and rear RETMA rails. Use a 2.5mm hex key Allen wrench to tighten front mounting brackets to the PDU chassis.

  3. Connect the Ground Bonding Cable

    Locate the external ground bonding point on the PDU chassis. Attach a ground bonding cable to this point using the provided external earthing screw and star washer. Bond the other end of the cable to a known earthed reference terminal in the building or to the rack's grounding strip/bus bar. Ensure the conductor size meets all national and local electrical codes (e.g., NEC Table 250.122).

  4. Connect the PDU to a Power Source

    WARNING: To reduce the risk of electric shock, ensure a reliable grounded connection before connecting AC power. Turn the feed circuit breaker OFF at the power source. Verify all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded branch circuit, adhering to all local and national electrical codes. Ensure the power cord has sufficient length. Once connected, turn the feed circuit breaker ON. Allow time for the PDU's operating system to load until the Main Menu displays.

  5. Rotate the Network Controller (Optional)

    If a specific orientation for the network controller's physical ports is desired, use a T10 Torx screwdriver to remove the two retaining screws. Carefully disconnect the ribbon cable to prevent damage. Rotate the controller to the desired orientation, then carefully reconnect the ribbon cable, ensuring proper orientation and avoiding pinching. Re-fasten the two screws using a T10 Torx screwdriver, torquing them to 2.2–3.1 lbf-in [0.25–0.35 N-M] to avoid metal deformation.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.